Greece
A New Approach to Vented Deflagration Modeling
Sep 2017
Publication
In the present work CFD simulations of a hydrogen deflagration experiment are performed. The experiment carried out by KIT was conducted in a 1 m3 enclosure with a square vent of 0.5 m2 located in the center of one of its walls. The enclosure was filled with homogeneous hydrogen-air mixture of 18% v/v before ignition at its back-wall. As the flame propagates away from the ignition point unburned mixture is forced out through the vent. This mixture is ignited when the flame passes through the vent initiating a violent external explosion which leads to a rapid increase in pressure. The work focuses on the modeling of the external explosion phenomenon. A new approach is proposed in order to predict with accuracy the strength of external explosions using Large Eddy Simulation. The new approach introduces new relations to account for the interaction between the turbulence and the flame front. CFD predictions of the pressure inside and outside the enclosure and of the flame front shape are compared against experimental measurements. The comparison indicates a much better performance of the new approach compared to the initial model.
Investigation of Hydrogen Embrittlement Susceptibility and Fracture Toughness Drop after in situ Hydrogen Cathodic Charging for an X65 Pipeline Steel
Apr 2020
Publication
The present research focuses on the investigation of an in situ hydrogen charging effect during Crack Tip Opening Displacement testing (CTOD) on the fracture toughness properties of X65 pipeline steel. This grade of steel belongs to the broader category of High Strength Low Alloy Steels (HSLA) and its microstructure consists of equiaxed ferritic and bainitic grains with a low volume fraction of degenerated pearlite islands. The studied X65 steel specimens were extracted from pipes with 19.15 mm wall thickness. The fracture toughness parameters were determined after imposing the fatigue pre-cracked specimens on air on a specific electrolytic cell under a slow strain rate bending loading (according to ASTM G147-98 BS7448 and ISO12135 standards). Concerning the results of this study in the first phase the hydrogen cations’ penetration depth the diffusion coefficient of molecular and atomic hydrogen and the surficial density of blisters were determined. Next the characteristic parameters related to fracture toughness (such as J KQ CTODel CTODpl) were calculated by the aid of the Force-Crack Mouth Open Displacement curves and the relevant analytical equations.
Choked Two-phase Flow with Account of Discharge Line Effects
Jan 2019
Publication
An engineering tool is presented to predict steady state two-phase choked flow through a discharge line with variable cross section with account of friction and without wall heat transfer. The tool is able to predict the distribution of all relevant physical quantities along the discharge line. Choked flow is calculated using the possible-impossible flow algorithm implemented in a way to account for possible density discontinuities along the line. Physical properties are calculated using the Helmholtz Free Energy formulation. The tool is verified against previous experiments with water and evaluated against previous experiments with cryogenic two-phase hydrogen.
Power to Hydrogen and Power to Water Using Wind Energy
May 2022
Publication
The need for energy and water security on islands has led to an increase in the use of wind power. However the intermittent nature of wind generation means it needs to be coupled with a storage system. Motivated by this two different models of surplus energy storage systems are investigated in this paper. In both models renewable wind energy is provided by a wind farm. In the first model a pumped hydro storage system (PHS) is used for surplus energy storage while in the second scenario a hybrid pumped hydrogen storage system (HPHS) is applied consisting of a PHS and a hydrogen storage system. The goal of this study is to compare the single and the hybrid storage system to fulfill the energy requirements of the island’s electricity load and desalination demands for domestic and irrigation water. The cost of energy (COE) is 0.287 EUR/kWh for PHS and 0.360 EUR/kWh for HPHS while the loss of load probability (LOLP) is 22.65% for PHS and 19.47% for HPHS. Sensitivity analysis shows that wind speed is the key parameter that most affects COE cost of water (COW) and LOLP indices while temperature affects the results the least.
Highly Resolved Large Eddy Simulation of Subsonic Hydrogen Jets – Evaluation of ADREA-HF Code Against Detailed Experiments
Sep 2019
Publication
The main objective of this work is the Large Eddy Simulation (LES) of hydrogen subsonic jets in order to evaluate modelling strategies and to provide guidelines for similar simulations. The ADREAHF code and the experiments conducted by Sandia National Laboratories are used for that purpose. These experiments are particularly ideal for LES studies because turbulent fluctuations have been measured which is something rare in hydrogen experiments. Hydrogen is released vertically from a small orifice of 1.91 mm diameter into an unconfined stagnant environment. Three experimental cases are simulated with different inlet velocity (49.7 76.0 and 133.9 m/s) which corresponds to transitional or turbulent flows. Hydrogen mass fraction and velocity mean values and fluctuations are compared against the experimental data. The Smagorinsky subgrid-scale model is mainly used. In the 49.7 m/s case the RNG LES is also evaluated. Several grid resolutions are used to assess the effect on the results. The amount of the resolved by the LES turbulence and velocity spectra are presented. Finally the effect of the release modelling is discussed.
Recent Progress in the Steam Reforming of Bio-Oil for Hydrogen Production: A Review of Operating Parameters, Catalytic Systems and Technological Innovations
Dec 2021
Publication
The present review focuses on the production of renewable hydrogen through the catalytic steam reforming of bio-oil the liquid product of the fast pyrolysis of biomass. Although in theory the process is capable of producing high yields of hydrogen in practice certain technological issues require radical improvements before its commercialization. Herein we illustrate the fundamental knowledge behind the technology of the steam reforming of bio-oil and critically discuss the major factors influencing the reforming process such as the feedstock composition the reactor design the reaction temperature and pressure the steam to carbon ratio and the hour space velocity. We also emphasize the latest research for the best suited reforming catalysts among the specific groups of noble metal transition metal bimetallic and perovskite type catalysts. The effect of the catalyst preparation method and the technological obstacle of catalytic deactivation due to coke deposition metal sintering metal oxidation and sulfur poisoning are addressed. Finally various novel modified steam reforming techniques which are under development are discussed such as the in-line two-stage pyrolysis and steam reforming the sorption enhanced steam reforming (SESR) and the chemical looping steam reforming (CLSR). Moreover we argue that while the majority of research studies examine hydrogen generation using different model compounds much work must be done to optimally treat the raw or aqueous bio-oil mixtures for efficient practical use. Moreover further research is also required on the reaction mechanisms and kinetics of the process as these have not yet been fully understood.
Renewable/Fuel Cell Hybrid Power System Operation Using Two Search Controllers of the Optimal Power Needed on the DC Bus
Nov 2020
Publication
In this paper the optimal and safe operation of a hybrid power system based on a fuel cell system and renewable energy sources is analyzed. The needed DC power resulting from the power flow balance on the DC bus is ensured by the FC system via the air regulator or the fuel regulator controlled by the power-tracking control reference or both regulators using a switched mode of the above-mentioned reference. The optimal operation of a fuel cell system is ensured by a search for the maximum of multicriteria-based optimization functions focused on fuel economy under perturbation such as variable renewable energy and dynamic load on the DC bus. Two search controllers based on the global extremum seeking scheme are involved in this search via the remaining fueling regulator and the boost DC–DC converter. Thus the fuel economy strategies based on the control of the air regulator and the fuel regulator respectively on the control of both fueling regulators are analyzed in this study. The fuel savings compared to fuel consumed using the static feed-forward control are 6.63% 4.36% and 13.72% respectively under dynamic load but without renewable power. With renewable power the needed fuel cell power on the DC bus is lower so the fuel cell system operates more efficiently. These percentages are increased to 7.28% 4.94% and 14.97%.
Fundamentals and Principles of Solid-State Electrochemical Sensors for High Temperature Gas Detection
Dec 2021
Publication
The rapid development of science technology and engineering in the 21st century has offered a remarkable rise in our living standards. However at the same time serious environmental issues have emerged such as acid rain and the greenhouse effect which are associated with the ever-increasing need for energy consumption 85% of which comes from fossil fuels combustion. From this combustion process except for energy the main greenhouse gases-carbon dioxide and steam-are produced. Moreover during industrial processes many hazardous gases are emitted. For this reason gas-detecting devices such as electrochemical gas sensors able to analyze the composition of a target atmosphere in real time are important for further improving our living quality. Such devices can help address environmental issues and inform us about the presence of dangerous gases. Furthermore as non-renewable energy sources run out there is a need for energy saving. By analyzing the composition of combustion emissions of automobiles or industries combustion processes can be optimized. This review deals with electrochemical gas sensors based on solid oxide electrolytes which are employed for the detection of hazardous gasses at high temperatures and aggressive environments. The fundamentals the principle of operation and the configuration of potentiometric amperometric combined (amperometric-potentiometric) and mixed-potential gas sensors are presented. Moreover the results of previous studies on carbon oxides (COx) nitrogen oxides (NOx) hydrogen (H2 ) oxygen (O2 ) ammonia (NH3 ) and humidity (steam) electrochemical sensors are reported and discussed. Emphasis is given to sensors based on oxygen ion and proton-conducting electrolytes.
Thermodynamic Analysis of Hydrogen Production via Chemical Looping Steam Methane Reforming Coupled with In Situ CO2 Capture
Dec 2014
Publication
A detailed thermodynamic analysis of the sorption enhanced chemical looping reforming of methane (SE-CL-SMR) using CaO and NiO as CO2 sorbent and oxygen transfer material (OTM) respectively was conducted. Conventional reforming (SMR) and sorption enhanced reforming (SE-SMR) were also investigated for comparison reasons. The results of the thermodynamic analysis show that there are significant advantages of both sorption enhanced processes compared to conventional reforming. The presence of CaO leads to higher methane conversion and hydrogen purity at low temperatures. Addition of the OTM in the SECL-SMR process concept minimizes the thermal requirements and results in superior performance compared to SE-SMR and SMR in a two-reactor concept with use of pure oxygen as oxidant/sweep gas.
Integration of a Dark Fermentation Effluent in a Microalgal-based Biorefinery for the Production of High-added Value Omega-3 Fatty Acids
Mar 2019
Publication
Dark fermentation is an anaerobic digestion process of biowaste used to produce hydrogen- for generation of energy- that however releases high amounts of polluting volatile fatty acids such as acetic acid in the environment. In order for this biohydrogen production process to become more competitive the volatile fatty acids stream can be utilized through conversion to high added-value metabolites such as omega-3 fatty acids. The docosahexaenoic acid is one of the two most known omega-3 fatty acids and has been found to be necessary for a healthy brain and proper cardiovascular function. The main source is currently fish which obtain the fatty acid from the primary producers microalgae through the food chain. Crypthecodinium cohnii a heterotrophic marine microalga is known for accumulating high amounts of docosahexaenoic acid while offering the advantage of assimilating various carbon sources such as glucose ethanol glycerol and acetic acid. The purpose of this work was to examine the ability of a C. cohnii strain to grow on different volatile fatty acids as well as on a pre-treated dark fermentation effluent and accumulate omega-3. The strain was found to grow well on relatively high concentrations of acetic butyric or propionic acid as main carbon source in a fed-batch pH-auxostat. Most importantly C. cohnii totally depleted the organic acid content of an ultra-filtrated dark fermentation effluent after 60 h of fed-batch cultivation therefore offering a bioprocess not only able to mitigate environmental pollutants but also to provide a solution for a sustainable energy production process. The accumulated docosahexaenoic acid content was as high as 29.8% (w/w) of total fatty acids.
Nonlinear Model Predictive Control of an Autonomous Power System Based on Hydrocarbon Reforming and High Temperature Fuel Cell
Mar 2021
Publication
The integration and control of energy systems for power generation consists of multiple heterogeneous subsystems such as chemical electrochemical and thermal and contains challenges that arise from the multi-way interactions due to complex dynamic responses among the involved subsystems. The main motivation of this work is to design the control system for an autonomous automated and sustainable system that meets a certain power demand profile. A systematic methodology for the integration and control of a hybrid system that converts liquefied petroleum gas (LPG) to hydrogen which is subsequently used to generate electrical power in a high-temperature fuel cell that charges a Li-Ion battery unit is presented. An advanced nonlinear model predictive control (NMPC) framework is implemented to achieve this goal. The operational objective is the satisfaction of power demand while maintaining operation within a safe region and ensuring thermal and chemical balance. The proposed NMPC framework based on experimentally validated models is evaluated through simulation for realistic operation scenarios that involve static and dynamic variations of the power load.
A Comparative CFD Assessment Study of Cryogenic Hydrogen and Liquid Natural Gas Dispersion
Sep 2017
Publication
The introduction of hydrogen to the commercial market as alternative fuel brings up safety concerns. Its storage in liquid or cryo-compressed state to achieve volumetric efficiency involves additional risks and their study is crucial. This work aims to investigate the behaviour of cryogenic hydrogen release and to study factors that affect the vapor dispersion. We focus on the effect of ambient humidity and air's components (nitrogen and oxygen) freezing in order to identify the conditions under which these factors have considerable influence. The study reveals that the level of influence depends highly on the release conditions and that humidity can reduce conspicuously the longitudinal distance of the Lower Flammability Limit (LFL). Low Froude (Fr) number (<1000) at the release allows the generated by the humidity phase change buoyancy to affect the dispersion while for higher Fr number - that usually are met in cryo-compressed releases - the momentum forces are the dominant forces and the buoyancy effect is trivial. Simulations with liquid methane release have been also performed and compared to the liquid hydrogen simulations in order to detect the differences in the behaviour of the two fuels as far as the humidity effect is concerned. It is shown that in methane spills the buoyancy effect in presence of humidity is smaller than in hydrogen spills and it can be considered almost negligible.
Effect of Corrosion-induced Hydrogen Embrittlement and its Degradation Impact on Tensile Properties and Fracture Toughness of (Al-Cu-Mg) 2024 Alloy
Jul 2016
Publication
In the present work the effect of artificial ageing of AA2024-T3 on the tensile mechanical properties and fracture toughness degradation due to corrosion exposure will be investigated. Tensile and fracture toughness specimens were artificially aged to tempers that correspond to Under-Ageing (UA) Peak-Ageing (PA) and Over-Ageing (OA) conditions and then were subsequently exposed to exfoliation corrosion environment. The corrosion exposure time was selected to be the least possible according to the experimental work of Alexopoulos et al. (2016) so as to avoid the formation of large surface pits trying to simulate the hydrogen embrittlement degradation only. The mechanical test results show that minimum corrosion-induced decrease in elongation at fracture was achieved for the peak-ageing condition while maximum was noticed at the under-ageing and over-ageing conditions. Yield stress decrease due to corrosion is less sensitive to tempering; fracture toughness decrease was sensitive to ageing heat treatment thus proving that the S΄ particles play a significant role on the corrosion-induced degradation.
Development of a Model Evaluation Protocol for CFD Analysis of Hydrogen Safety Issues – The SUSANA Project
Oct 2015
Publication
The “SUpport to SAfety aNAlysis of Hydrogen and Fuel Cell Technologies (SUSANA)” project aims to support stakeholders using Computational Fluid Dynamics (CFD) for safety engineering design and assessment of FCH systems and infrastructure through the development of a model evaluation protocol. The protocol covers all aspects of safety assessment modelling using CFD from release through dispersion to combustion (self-ignition fires deflagrations detonations and Deflagration to Detonation Transition - DDT) and not only aims to enable users to evaluate models but to inform them of the state of the art and best practices in numerical modelling. The paper gives an overview of the SUSANA project including the main stages of the model evaluation protocol and some results from the on-going benchmarking activities.
Numerical Prediction of Cryogenic Hydrogen Vertical Jets
Sep 2019
Publication
Comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refuelling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However for test with 3 and 4 bar release the concentration was overpredicted. Furthermore a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.
Removing the Disrupting Wind Effect in Single Vented Enclosure Exposed to External Wind
Oct 2015
Publication
We are addressing hydrogen release into a single-vented facility with wind blowing onto the opposite side of the vent wall. Earlier work based on tests performed by HSL with wind (within the HyIndoor project) and comparative CFD simulations with and without wind ([1]within the H2FC project) has shown that the hydrogen concentrations inside the enclosure are increased compared to the case with no wind. This was attributed to the fact that wind is disrupting the passive ventilation. The present work is based on the GAMELAN tests (within the HyIndoor project) performed with one vent and no wind. For this enclosure simulations were performed with and without wind and reproduced the disrupting wind effect. In order to remove this effect and enhance the ventilation additional simulations were performed by considering different geometrical modifications near the vent. A simple geometrical layout around the vent is here proposed that leads to elimination of the disrupting wind effect. The analysis has been performed using the ADREA-HF code earlier validated both for the HSL and the GAMELAN tests. The current work was performed partly within HyIndoor project
Guidelines and Recommendations for Indoor Use of Fuel Cells and Hydrogen Systems
Oct 2015
Publication
Deborah Houssin-Agbomson,
Simon Jallais,
Elena Vyazmina,
Guy Dang-Nhu,
Gilles Bernard-Michel,
Mike Kuznetsov,
Vladimir V. Molkov,
Boris Chernyavsky,
Volodymyr V. Shentsov,
Dmitry Makarov,
Randy Dey,
Philip Hooker,
Daniele Baraldi,
Evelyn Weidner,
Daniele Melideo,
Valerio Palmisano,
Alexandros G. Venetsanos,
Jan Der Kinderen and
Béatrice L’Hostis
Hydrogen energy applications often require that systems are used indoors (e.g. industrial trucks for materials handling in a warehouse facility fuel cells located in a room or hydrogen stored and distributed from a gas cabinet). It may also be necessary or desirable to locate some hydrogen system components/equipment inside indoor or outdoor enclosures for security or safety reasons to isolate them from the end-user and the public or from weather conditions.<br/>Using of hydrogen in confined environments requires detailed assessments of hazards and associated risks including potential risk prevention and mitigation features. The release of hydrogen can potentially lead to the accumulation of hydrogen and the formation of a flammable hydrogen-air mixture or can result in jet-fires. Within Hyindoor European Project carried out for the EU Fuel Cells and Hydrogen Joint Undertaking safety design guidelines and engineering tools have been developed to prevent and mitigate hazardous consequences of hydrogen release in confined environments. Three main areas are considered: Hydrogen release conditions and accumulation vented deflagrations jet fires and including under-ventilated flame regimes (e.g. extinguishment or oscillating flames and steady burns). Potential RCS recommendations are also identified.
CFD Benchmark Based on Experiments of Helium Dispersion in a 1m3 Enclosure–intercomparisons for Plumes
Sep 2013
Publication
In the context of the French DIMITRHY project ANR-08-PANH006 experiments have been carried out to measure helium injections in a cubic 1 m3 box - GAMELAN in a reproducible and quantitative manner. For the present work we limit ourselves to the unique configuration of a closed box with a small hole at its base to prevent overpressure. This case leads to enough difficulties of modelisations to deserve our attention. The box is initially filled with air and injections of helium through a tube of diameter 20 mm is operated. The box is instrumented with catharometres to measure the helium volume concentration within an accuracy better than 0.1%. We present the CFD (Fluent and CASTEM ANSYS-CFX and ADREA-HF) calculations results obtained by 5 different teams participating to the benchmark in the following situation: the case of a plume release of helium in a closed box (4NL/min). Parts of the CFD simulations were performed in the European co-funded project HyIndoor others were performed in the French ANR-08-PANH006 DimitrHy project.
LES Modelling Of Hydrogen Release and Accumulation Within a Non-Ventilated Ambient Pressure Garage Using The Adrea-HF CFD Code
Sep 2011
Publication
Computational Fluid Dynamics (CFD) has already proven to be a powerful tool to study the hydrogen dispersion and help in the hydrogen safety assessment. In this work the Large Eddy Simulation (LES) recently incorporated into the ADREA-HF CFD code is evaluated against the INERIS-6C experiment of hydrogen leakage in a supposed garage which provides detailed experimental measurements visualization of the flow and availability of previous CFD results from various institutions (HySafe SBEP-V3). The short-term evolution of the hydrogen concentrations in this confined space is examined and comparison with experimental data is provided along with comments about the ability of LES to capture the transient phenomena occurring during hydrogen dispersion. The influence of the value of the Smagorinsky constant on the resolved and on the unresolved turbulence is also presented. Furthermore the renormalization group (RNG) LES methodology is also tested and its behaviour in both highly-turbulent and less-turbulent parts of the flow is highlighted.
CFD Simulations on Small Hydrogen Releases Inside a Ventilated Facility and Assessment of Ventilation Efficiency
Sep 2009
Publication
The use of stationary H2 and fuel cell systems is expected to increase rapidly in the future. In order to facilitate the safe introduction of this new technology the HyPer project funded by the EC developed a public harmonized Installation Permitting Guidance (IPG) document for the installation of small stationary H2 and fuel cell systems for use in various environments. The present contribution focuses on the safety assessment of a facility inside which a small H2 fuel cell system (4.8 kWe) is installed and operated. Dispersion experiments were designed and performed by partner UNIPI. The scenarios considered cover releases occurring inside the fuel cell at the valve of the inlet gas pipeline just before the pressure regulator which controls the H2 flow to the fuel cell system. H2 was expected to leak out of the fuel cell into the facility and then outdoors through the ventilation system. The initial leakage diameter was chosen based on the Italian technical guidelines for the enforcement of the ATEX European directive. Several natural ventilation configurations were examined. The performed tests were simulated by NCSRD using the ADREA-HF code. The numerical analysis took into account the full interior of the fuel cell in order to investigate for any potential accumulation effects. Comparisons between predicted and experimental H2 concentrations at 4 sensor locations inside the facility are reported. Finally an overall assessment of the ventilation efficiency was made based on the simulations and experiments.
Sizing, Optimization, and Financial Analysis of a Green Hydrogen Refueling Station in Remote Regions
Jan 2022
Publication
Hydrogen (H2 ) can be a promising energy carrier for decarbonizing the economy and especially the transport sector which is considered as one of the sectors with high carbon emissions due to the extensive use of fossil fuels. H2 is a nontoxic energy carrier that could replace fossil fuels. Fuel Cell Electric Vehicles (FCEVs) can decrease air pollution and reduce greenhouse gases when H2 is produced from Renewable Energy Sources (RES) and at the same time being accessible through a widespread network of Hydrogen Refueling Stations (HRSs). In this study both the sizing of the equipment and financial analysis were performed for an HRS supplied with H2 from the excess electrical energy of a 10 MW wind park. The aim was to determine the optimum configuration of an HRS under the investigation of six different scenarios with various numbers of FCEVs and monthly demands as well as ascertaining the economic viability of each examined scenario. The effect of the number of vehicles that the installation can refuel to balance the initial cost of the investment and the fuel cost in remote regions was investigated. The results showed that a wind-powered HRS could be a viable solution when sized appropriately and H2 can be used as a storage mean for the rejected wind energy. It was concluded that scenarios with low FCEVs penetration have low economic performance since the payback period presented significantly high values.
Status of the Pre-normative Research Project PRESLHY for the Safe Use of LH2
Sep 2019
Publication
Liquid hydrogen (LH2) compared to compressed gaseous hydrogen offers advantages for large scale transport and storage of hydrogen with higher densities and potentially better safety performance. Although the gas industry has good experience with LH2 only little experience is available for the new applications of LH2 as an energy carrier. Therefore the European FCH JU funded project PRESLHY conducts pre-normative research for the safe use of cryogenic LH2 in non-industrial settings. The work program consists of a preparatory phase where the state of the art before the project has been summarized and where the experimental planning was adjusted to the outcome of a research priorities workshop. The central part of the project consists of 3 phenomena oriented work packages addressing Release Ignition and Combustion with analytical approaches experiments and simulations. The results shall improve the general understanding of the behavior of LH2 in accidents and thereby enhance the state-of-the-art what will be reflected in appropriate recommendations for development or revision of specific international standards. The paper presents the status of the project at the middle of its terms.
Evaluation of the ADREA-HF CFD Code Against a Hydrogen Deflagration in a Tunnel
Sep 2013
Publication
In the present work the capabilities of the computational fluid dynamics (CFD) code ADREA-HF to predict deflagration in homogenous near stoichiometric hydrogen-air mixture in a model of a tunnel were tested. The tunnel is 78.5 m long. Hydrogen-air mixture is located in a 10 m long region in the middle of the tunnel. Two cases are studied: one with a complete empty tunnel and one with the presence of four vehicles near the center of the tunnel. The combustion model is based on the turbulent flame speed concept. The turbulent flame speed is a modification of Yakhot's equation in order to account for additional physical mechanisms. A sensitivity analysis for the parameter of the combustion model and for the mesh resolution was made for the empty tunnel case. The agreement between experimental and computational results concerning the value of the maximum pressure and the time it appears is satisfactory in both cases. The sensitivity analysis for the parameter of the combustion model showed that even small changes in it can have impact on the simulating results whereas the sensitivity analysis of the mesh resolution did not reveal any significant differences.
Modeling of Cryogenic Hydrogen jets
Oct 2015
Publication
In the present work the CFD modeling of cryogenic hydrogen releases in quiescent environment is presented. Two tests from the series of experiments performed in the ICESAFE facility at KIT (Karlsruhe Institute for Technology) have been simulated within the SUSANA project. During these tests hydrogen at temperature of 37K and 36K and at pressure of 19 and 29 bars respectively is released horizontally. The release at the nozzle is sonic and the modeling of the under-expanded jet was performed using two different approaches: the Ewan and Moodie approach and a modification of the Ewan and Moodie approach (modified Ewan and Moodie) that is introduced here and employs the momentum balance to calculate the velocity in the under-expanded jet. Using these approaches a pseudo-diameter is calculated and this diameter is set as source boundary in the simulation. Predictions are consistent with measurements for both experiments with both approaches. However the Ewan and Moodie approach seems to perform better.
Methanol Reforming Processes for Fuel Cell Applications
Dec 2021
Publication
Hydrogen production through methanol reforming processes has been stimulated over the years due to increasing interest in fuel cell technology and clean energy production. Among different types of methanol reforming the steam reforming of methanol has attracted great interest as reformate gas stream where high concentration of hydrogen is produced with a negligible amount of carbon monoxide. In this review recent progress of the main reforming processes of methanol towards hydrogen production is summarized. Different catalytic systems are reviewed for the steam reforming of methanol: mainly copper- and group 8–10-based catalysts highlighting the catalytic key properties while the promoting effect of the latter group in copper activity and selectivity is also discussed. The effect of different preparation methods different promoters/stabilizers and the formation mechanism is analyzed. Moreover the integration of methanol steam reforming process and the high temperature–polymer electrolyte membrane fuel cells (HT-PEMFCs) for the development of clean energy production is discussed.
CFD Modeling OF LH2 Dispersion Using the ADREA-HF Code
Sep 2011
Publication
In the present work the computational fluid dynamics (CFD) code ADREA-HF has been applied to simulate the very recent liquefied hydrogen spill experiments performed by the Health Safety Laboratory (HSL). The experiment consists of four LH2 release trials over concrete at a fixed rate of 60 lt/min but with different release direction height and duration. In the modeling the hydrogen source was treated as a two phase jet enabling simultaneous modeling of pool formation spreading as well as hydrogen vapor dispersion. Turbulence was modeled with the standard k- model modified for buoyancy effects. The effect of solidification of the atmospheric humidity was taken into account. The predicted concentration at the experimental sensors? locations was compared with the observed one. The results from the comparison of the predicted concentration with and without solidification of the atmospheric humidity indicate that the released heat from the solidification affects significantly the buoyant behavior of the hydrogen vapor. Therefore the simulation with solidification of the atmospheric humidity is in better agreement with the experiment.
Evaluation of an Improved Vented Deflagration CFD Model Against Nine Experimental Cases
Sep 2019
Publication
In the present work a newly developed CFD deflagration model incorporated into the ADREA-HF code is evaluated against hydrogen vented deflagrations experiments carried out by KIT and FM-Global in a medium (1 m3) and a real (63.7 m3) scale enclosure respectively. A square vent of 0.5 m2 and 5.4 m2 respectively is located in the center of one of side walls. In the case of the medium scale enclosure the 18% v/v homogeneous hydrogen-air mixture and back-wall ignition case is examined. In the case of the real scale enclosure the examined cases cover different homogeneous mixture concentrations (15% and 18% v/v) different ignition locations (back-wall and center) and different levels of initial turbulence. The CFD model accounts for flame instabilities that develop as the flame propagates inside the chamber and turbulence that mainly develops outside the vent. Pressure predictions are compared against experimental measurements revealing a very good performance of the CFD model for the back-wall ignition cases. For the center ignition cases the model overestimates the maximum overpressure. The opening of the vent cover is identified as a possible reason for the overprediction. The analysis indicates that turbulence is the main factor which enhances external explosion strength causing the sudden pressure increase confirming previous findings.
Methodology for the Development of Hybrid Renewable Energy Systems (HRES) with Pumped Storage and Hydrogen Production on Lemnos Island
Apr 2022
Publication
The non-interconnected islands of Greece can benefit from the comprehensive use of RES to avoid water droughts and ensure energy autonomy. The present paper analyzes an HRES with two possible operating scenarios. Both of them include a wind park of 27.5 MW capacity an 1175 m3/day desalination plant and a 490000 m3/day water tank in Lemnos Greece. Regarding the wind power 70% is used in the HRES while the rest is channeled directly to the grid. The main difference comes down to how the wind energy is stored either in the form of hydraulic energy or in the form of hydrogen. The lifespan of the system is 25 years such as the produced stochastic series of rainfall temperature and wind of the area. Through the comparison of the operating scenarios the following results arise: (i) the water needs of the island are fully covered and the irrigation needs have a reliability of 66% in both scenarios. (ii) Considering the energy needs the pumping storage seems to be the most reliable solution. (iii) However depending on the amount of wind energy surplus the use of hydrogen could produce more energy than the hydroelectric plant.
CFD Modeling for Helium Releases in a Private Garage Without Forced Ventilation.
Sep 2005
Publication
In the course towards a safe future hydrogen based society one of the tasks to be considered is the investigation of the conditions under which the use or storage of hydrogen systems inside buildings becomes too dangerous to be accepted. One of the relevant scenarios which is expected to have a relatively high risk is a slow (and long lasting) hydrogen release from a vehicle stored in a closed private garage without any forced ventilation i.e. only with natural ventilation. This scenario has been earlier investigated experimentally (by M. Swain) using He (helium) to simulate the hydrogen behavior. In the present work the CFD code ADREA-HF is used to simulate three of the abovementioned experiments using the standard k- turbulence model. For each case modeled the predicted concentration (by vol.) time series are compared against the experimental at the given sensor locations. In addition the structure of the flow is investigated by presenting the helium concentration field.
Best Practice in Numerical Simulation and CFD Benchmarking. Results from the SUSANA Project
Sep 2017
Publication
Correct use of Computational Fluid Dynamics (CFD) tools is essential in order to have confidence in the results. A comprehensive set of Best Practice Guidelines (BPG) in numerical simulations for Fuel Cells and Hydrogen applications has been one of the main outputs of the SUSANA project. These BPG focus on the practical needs of engineers in consultancies and industry undertaking CFD simulations or evaluating CFD simulation results in support of hazard/risk assessments of hydrogen facilities as well as on the needs of regulatory authorities. This contribution presents a summary of the BPG document. All crucial aspects of numerical simulations are addressed such as selection of the physical models domain design meshing boundary conditions and selection of numerical parameters. BPG cover all hydrogen safety relative phenomena i.e. release and dispersion ignition jet fire deflagration and detonation. A series of CFD benchmarking exercises are also presented serving as examples of appropriate modelling strategies.
On the Use of Hydrogen in Confined Spaces: Results from the Internal Project InsHyde
Sep 2009
Publication
Alexandros G. Venetsanos,
Paul Adams,
Inaki Azkarate,
A. Bengaouer,
Marco Carcassi,
Angunn Engebø,
E. Gallego,
Olav Roald Hansen,
Stuart J. Hawksworth,
Thomas Jordan,
Armin Keßler,
Sanjay Kumar,
Vladimir V. Molkov,
Sandra Nilsen,
Ernst Arndt Reinecke,
M. Stöcklin,
Ulrich Schmidtchen,
Andrzej Teodorczyk,
D. Tigreat,
N. H. A. Versloot and
L. Boon-Brett
The paper presents an overview of the main achievements of the internal project InsHyde of the HySafe NoE. The scope of InsHyde was to investigate realistic small-medium indoor hydrogen leaks and provide recommendations for the safe use/storage of indoor hydrogen systems. Additionally InsHyde served to integrate proposals from HySafe work packages and existing external research projects towards a common effort. Following a state of the art review InsHyde activities expanded into experimental and simulation work. Dispersion experiments were performed using hydrogen and helium at the INERIS gallery facility to evaluate short and long term dispersion patterns in garage like settings. A new facility (GARAGE) was built at CEA and dispersion experiments were performed there using helium to evaluate hydrogen dispersion under highly controlled conditions. In parallel combustion experiments were performed by FZK to evaluate the maximum amount of hydrogen that could be safely ignited indoors. The combustion experiments were extended later on by KI at their test site by considering the ignition of larger amounts of hydrogen in obstructed environments outdoors. An evaluation of the performance of commercial hydrogen detectors as well as inter-lab calibration work was jointly performed by JRC INERIS and BAM. Simulation work was as intensive as the experimental work with participation from most of the partners. It included pre-test simulations validation of the available CFD codes against previously performed experiments with significant CFD code inter-comparisons as well as CFD application to investigate specific realistic scenarios. Additionally an evaluation of permeation issues was performed by VOLVO CEA NCSRD and UU by combining theoretical computational and experimental approaches with the results being presented to key automotive regulations and standards groups. Finally the InsHyde project concluded with a public document providing initial guidance on the use of hydrogen in confined spaces.
Comparison of Convective Schemes in Hydrogen Impinging Jet CFD Simulation
Oct 2015
Publication
Hydrogen impinging jets can be formed in the case of an accidental release indoors or outdoors. The CFD simulation of hydrogen impinging jets suffers from numerical errors resulting in a non-physical velocity and hydrogen concentration field with a butterfly like structure. In order to minimize the numerical errors and to avoid the butterfly effect high order schemes need to be used. The aim of this work is to give best practices guidelines for hydrogen impinging jet simulations. A number of different numerical schemes is evaluated. The number of cells which discretize the source is also examined.
Hysafe SBEP-V20: Numerical Predictions of Release Experiments Inside a Residential Garage With Passive Ventilation
Sep 2009
Publication
This work presents the results of the Standard Benchmark Exercise Problem (SBEP) V20 of Work Package 6 (WP6) of HySafe Network of Excellence (NoE) co-funded by the European Commission in the frame of evaluating the quality and suitability of codes models and user practices by comparative assessments of code results. The benchmark problem SBEP-V20 covers release scenarios that were experimentally investigated in the past using helium as a substitute to hydrogen. The aim of the experimental investigations was to determine the ventilation requirements for parking hydrogen fuelled vehicles in residential garages. Helium was released under the vehicle for 2 h with 7.200 l/h flow rate. The leak rate corresponded to a 20% drop of the peak power of a 50 kW fuel cell vehicle. Three double vent garage door geometries are considered in this numerical investigation. In each case the vents are located at the top and bottom of the garage door. The vents vary only in height. In the first case the height of the vents is 0.063 m in the second 0.241 m and in the third 0.495 m. Four HySafe partners participated in this benchmark. The following CFD packages with the respective models were applied to simulate the experiments: ADREA-HF using k–ɛ model by partner NCSRD FLACS using k–ɛ model by partner DNV FLUENT using k–ɛ model by partner UPM and CFX using laminar and the low-Re number SST model by partner JRC. This study compares the results predicted by the partners to the experimental measurements at four sensor locations inside the garage with an attempt to assess and validate the performance of the different numerical approaches.
Estimation of an Allowable Hydrogen Permeation Rate From Road Vehicle Compressed Gaseous H2 Storage Systems In Typical Garages, Part 2: CFC Dispersion Calculations Using the ADREA-HF Code and Experimental Validation Using Helium Tests at the Garage Facility
Sep 2009
Publication
The time and space evolution of the distribution of hydrogen in confined settings was investigated computationally and experimentally for permeation from typical compressed gaseous hydrogen storage systems for buses or cars. The work was performed within the framework of the InsHyde internal project of the HySafe NoE funded by EC. The main goal was to examine whether hydrogen is distributed homogeneously within a garage like facility or whether stratified conditions are developed under certain conditions. The nominal hydrogen flow rate considered was 1.087 NL/min based on the then current SAE standard for composite hydrogen containers with a non-metallic liner (type 4) at simulated end of life and maximum material temperature in a bus facility with a volume of 681m3. The release was assumed to be directed upwards from a 0.15m diameter hole located at the middle part of the bus cylinders casing. Ventilation rates up to 0.03 ACH were considered. Simulated time periods extended up to 20 days. The CFD simulations performed with the ADREA-HF code showed that fully homogeneous conditions exist for low ventilation rates while stratified conditions prevail for higher ventilation rates. Regarding flow structure it was found that the vertical concentration profiles can be considered as the superposition of the concentration at the floor (driven by laminar diffusion) plus a concentration difference between floor and ceiling (driven by buoyancy forces). In all cases considered this concentration difference was found to be less than 0.5%. The dispersion experiments were performed at the GARAGE facility using Helium. Comparison between CFD simulations and experiments showed that the predicted concentrations were in good agreement with the experimental data. Finally simulations were performed using two integral models: the fully homogeneous model and the two-layer model proposed by Lowesmith et al. (ICHS-2 2007) and the results were compared both against CFD and the experimental data.
A Reappraisal of Containment Safety Under Hydrogen Detonation
Sep 2005
Publication
The response of a typical steel-lined reinforced concrete nuclear reactor containment to postulated internal hydrogen detonations is investigated by detailed axisymetric non-linear dynamic finite element analysis. The wall pressure histories are calculated for hydrogen detonations using a technique that reproduces the sharp discontinuity at the shock front. The pressure results can be applied to geometrically similar vessels. The analysis indicates that the response is more sensitive to the point of initiation than to the strength of the detonation. Approximate solutions based on a pure impulse assumption where the containment is modelled as a single-degree-of freedom (SDOF) system may be seriously unconservative. This work becomes relevant because new nuclear reactors are foreseen as a primary of source of hydrogen supply.<br/><br/>
Consequence Assessment of the BBC Hydrogen Refuelling Station, Using The Adrea-Hf Code
Sep 2009
Publication
Within the framework of the internal project HyQRA of the HYSAFE Network of Excellence (NoE) funded by the European Commission (EC) the participating partners were requested to apply their Quantitative Risk Assessment (QRA) methodologies on a predefined hypothetical gaseous H2 refuelling station named BBC (Benchmark Base Case). The overall aim of the HyQRA project was to perform an inter-comparison of the various QRA approaches and to identify the knowledge gaps on data and information needed in the QRA steps specifically related to H2. Partners NCSRD and UNIPI collaborated on a common QRA. UNIPI identified the hazards on site selected the most critical ones defined the events that could be the primary cause of an accident and provided to NCSRD the scenarios listed in risk order for the evaluation of the consequences. NCSRD performed the quantitative analysis using the ADREA-HF CFD code. The predicted risk assessment parameters (flammable H2 mass and volume time histories and maximum horizontal and vertical distances of the LFL from the source) were provided to UNIPI to analyze the consequences and to evaluate the risk and distances of damage. In total 15 scenarios were simulated. Five of them were H2 releases in confined ventilated spaces (inside the compression and the purification/drying buildings). The remaining 10 scenarios were releases in open/semi-confined spaces (in the storage cabinet storage bank and refuelling hose of one dispenser). This paper presents the CFD methodology applied for the quantitative analysis of the common UNIPI/NCSRD QRA and discusses the results obtained from the performed calculations.
The Effect of Cold Rolling on the Hydrogen Susceptibility of 5083 Aluminium Alloy
Oct 2017
Publication
This work focuses in investigating the effect of cold deformation on the cathodic hydrogen charging of 5083 aluminum alloy. The aluminium alloy was submitted to a cold rolling process until the average thickness of the specimens was reduced by 7% and 15% respectively. A study of the structure microhardness and tensile properties of the hydrogen charged aluminium specimens with and without cold rolling indicated that the cold deformation process led to an increase of hydrogen susceptibility of this aluminum alloy.
Numerical Simulation of Tensile Behavior of Corroded Aluminum Alloy 2024 T3 Considering the Hydrogen Embrittlement
Jan 2018
Publication
A multi-scale modeling approach for simulating the tensile behavior of the corroded aluminum alloy 2024 T3 was developed accounting for both the geometrical features of corrosion damage and the effect of corrosion-induced hydrogen embrittlement (HE). The approach combines two Finite Element (FE) models: a model of a three-dimensional Representative Unit Cell (RUC) representing an exfoliated area and its correspondent hydrogen embrittled zone (HEZ) and a model of the tensile specimen. The models lie at the micro- and macro-scales respectively. The characteristics of the HEZ are determined from measurements of nanoindentation hardness conducted on pre-corroded specimens. Using the model of the RUC the local homogenized mechanical behavior of the corroded material is simulated. Then the behavior of the exfoliated areas is assigned into different areas (elements) of the tensile specimen and final analyses are performed to simulate the tensile behavior of the corroded material. The approach was applied to model specimens after 8 16 and 24 h exposure periods of the Exfoliation Corrosion (EXCO) test. For validation of the approach tensile tests were used. The numerical results show that this approach is suitable for accurately simulating the tensile behavior of pre-corroded experimental specimens accounting for both geometrical features of corrosion damage and corrosion-induced HE.
Exergetic Aspects of Hydrogen Energy Systems—The Case Study of a Fuel Cell Bus
Feb 2017
Publication
Electrifying transportation is a promising approach to alleviate climate change issues arising from increased emissions. This study examines a system for the production of hydrogen using renewable energy sources as well as its use in buses. The electricity requirements for the production of hydrogen through the electrolysis of water are covered by renewable energy sources. Fuel cells are being used to utilize hydrogen to power the bus. Exergy analysis for the system is carried out. Based on a steady-state model of the processes exergy efficiencies are calculated for all subsystems. The subsystems with the highest proportion of irreversibility are identified and compared. It is shown that PV panel has exergetic efficiency of 12.74% wind turbine of 45% electrolysis of 67% and fuel cells of 40%.
Editorial—Special Issue “Catalysis for Energy Production”
Jun 2021
Publication
The rapid increase in anthropogenic greenhouse gas concentrations in the last several decades means that the effects of climate change are fast becoming the familiar horsemen of a planetary apocalypse. Catalysis one of the pillars of the chemical and petrochemical industries will play a critical role in the effort to reduce the flow of greenhouse gases into the atmosphere. This Special Issue is timely as it provides a collection of high-quality manuscripts in a diverse range of topics which include the production of green hydrogen via water electrolysis the steam reforming of ethanol propane or glycerol the dry reforming of methane and the autothermal reforming of diesel surrogate fuel. The topic of the transformation of biomass waste to chemicals is also well represented as is the tackling of CO2 emissions via novel utilization technologies. The Editors are grateful to all authors for their valuable contributions and confident that this Special Issue will prove valuable to scholars university professors and students alike.
Up-scalable Emerging Energy Conversion Technologies Enabled by 2D Materials: From Miniature Power Harvesters Towards Grid-connected Energy Systems
May 2021
Publication
Breakthrough discoveries in high-throughput formulation of abundant materials and advanced engineering approaches are both in utter need as prerequisites for developing novel large-scale energy conversion technologies required to address our planet's rising energy demands. Nowadays the rapid deployment of Internet of Things (IoT) associated with a distributed network of power-demanding smart devices concurrently urges for miniaturized systems powered by ambient energy harvesting. Graphene and other related two-dimensional materials (GRM) consist a perfect fit to drive this innovation owing to their extraordinary optoelectronic physical and chemical properties that emerge at the limit of two-dimensions. In this review after a critical analysis of GRM's emerging properties that are beneficial for power generation novel approaches are presented for developing ambient energy conversion devices covering a wide range of scales. Notable examples vary from GRM-enabled large-scale photovoltaic panels and fuel cells smart hydrovoltaics and blue energy conversion routes to miniaturized radio frequency piezoelectric triboelectric and thermoelectric energy harvesters. The insights from this review demonstrate that GRM-enabled energy harvesters apart from enabling the self-powered operation of individual IoT devices have also the potential to revolutionize the way that grid-electricity is provided in the cities of the future. This approach is materialized by two complementary paradigms: cross-coupled integration of GRM into firstly a network consisted of a vast number of miniaturized in-series-connected harvesters and secondly into up-scaled multi-energy hybrid harvesters both approaches having the potential for on-grid energy generation under all-ambient-conditions. At the end of the discussion perspectives on the trends limitations and commercialisation potential of these emerging up-scalable energy conversion technologies are provided. This review aims to highlight the importance of building a network of GRM-based cross-scaled energy conversion systems and their potential to become the guideline for the energy sustainable cities of the future.
Hydrogen in Grid Balancing: The European Market Potential for Pressurized Alkaline Electrolyzers
Jan 2022
Publication
To limit the global temperature change to no more than 2 ◦C by reducing global emissions the European Union (EU) set up a goal of a 20% improvement on energy efficiency a 20% cut of greenhouse gas emissions and a 20% share of energy from renewable sources by 2020 (10% share of renewable energy (RE) specifically in the transport sector). By 2030 the goal is a 27% improvement in energy efficiency a 40% cut of greenhouse gas emissions and a 27% share of RE. However the integration of RE in energy system faces multiple challenges. The geographical distribution of energy supply changes significantly the availability of the primary energy source (wind solar water) and is the determining factor rather than where the consumers are. This leads to an increasing demand to match supply and demand for power. Especially intermittent RE like wind and solar power face the issue of energy production unrelated to demand (issue of excess energy production beyond demand and/or grid capacity) and forecast errors leading to an increasing demand for grid services like balancing power. Megawatt electrolyzer units (beyond 3 MW) can provide a technical solution to convert large amounts of excess electricity into hydrogen for industrial applications substitute for natural gas or the decarbonization of the mobility sector. The demonstration of successful MW electrolyzer operation providing grid services under dynamic conditions as request by the grid can broaden the opportunities of new business models that demonstrate the profitability of an electrolyzer in these market conditions. The aim of this work is the demonstration of a technical solution utilizing Pressurized Alkaline Electrolyzer (PAE) technology for providing grid balancing services and harvesting Renewable Energy Sources (RES) under realistic circumstances. In order to identify any differences between local market and grid requirements the work focused on a demonstration site located in Austria deemed as a viable business case for the operation of a largescale electrolyzer. The site is adapted to specific local conditions commonly found throughout Europe. To achieve this this study uses a market-based solution that aims at providing value-adding services and cash inflows stemming from the grid balancing services it provides. Moreover the work assesses the viability of various business cases by analyzing (qualitatively and quantitatively) additional business models (in terms of business opportunities/energy source potential grid service provision and hydrogen demand) and analyzing the value and size of the markets developing recommendations for relevant stakeholder to decrease market barriers.
Blind-prediction: Estimating the Consequences of Vented Hydrogen Deflagrations for Homogeneous Mixtures in a 20-foot ISO Container
Sep 2017
Publication
Trygve Skjold,
Helene Hisken,
Sunil Lakshmipathy,
Gordon Atanga,
Marco Carcassi,
Martino Schiavetti,
James R. Stewart,
A. Newton,
James R. Hoyes,
Ilias C. Tolias,
Alexandros G. Venetsanos,
Olav Roald Hansen,
J. Geng,
Asmund Huser,
Sjur Helland,
Romain Jambut,
Ke Ren,
Alexei Kotchourko,
Thomas Jordan,
Jérome Daubech,
Guillaume Lecocq,
Arve Grønsund Hanssen,
Chenthil Kumar,
Laurent Krumenacker,
Simon Jallais,
D. Miller and
Carl Regis Bauwens
This paper summarises the results from a blind-prediction study for models developed for estimating the consequences of vented hydrogen deflagrations. The work is part of the project Improving hydrogen safety for energy applications through pre-normative research on vented deflagrations (HySEA). The scenarios selected for the blind-prediction entailed vented explosions with homogeneous hydrogen-air mixtures in a 20-foot ISO container. The test program included two configurations and six experiments i.e. three repeated tests for each scenario. The comparison between experimental results and model predictions reveals reasonable agreement for some of the models and significant discrepancies for others. It is foreseen that the first blind-prediction study in the HySEA project will motivate developers to improve their models and to update guidelines for users of the models.
Results of the Pre-normative Research Project PRESLHY for the Safe Use of Liquid Hydrogen
Sep 2021
Publication
Liquid hydrogen (LH2) compared to compressed gaseous hydrogen offers advantages for large-scale transport and storage of hydrogen with higher densities. Although the gas industry has good experience with LH2 only little experience is available for the new applications of LH2 as an energy carrier. Therefore the European FCH JU funded project PRESLHY conducted pre-normative research for the safe use of cryogenic LH2 in non-industrial settings. The central research consisted of a broad experimental program combined with analytical work modelling and simulations belonging to the three key phenomena of the accident chain: release and mixing ignition and combustion. The presented results improve the general understanding of the behavior of LH2 in accidents and provide some design guidelines and engineering tools for safer use of LH2. Recommendations for improvement of current international standards are derived.
Renewable Power and Heat for the Decarbonisation of Energy-Intensive Industries
Dec 2022
Publication
The present review provides a catalogue of relevant renewable energy (RE) technologies currently available (regarding the 2030 scope) and to be available in the transition towards 2050 for the decarbonisation of Energy Intensive Industries (EIIs). RE solutions have been classified into technologies based on the use of renewable electricity and those used to produce heat for multiple industrial processes. Electrification will be key thanks to the gradual decrease in renewable power prices and the conversion of natural-gas-dependent processes. Industrial processes that are not eligible for electrification will still need a form of renewable heat. Among them the following have been identified: concentrating solar power heat pumps and geothermal energy. These can supply a broad range of needed temperatures. Biomass will be a key element not only in the decarbonisation of conventional combustion systems but also as a biofuel feedstock. Biomethane and green hydrogen are considered essential. Biomethane can allow a straightforward transition from fossil-based natural gas to renewable gas. Green hydrogen production technologies will be required to increase their maturity and availability in Europe (EU). EIIs’ decarbonisation will occur through the progressive use of an energy mix that allows EU industrial sectors to remain competitive on a global scale. Each industrial sector will require specific renewable energy solutions especially the top greenhouse gas-emitting industries. This analysis has also been conceived as a starting point for discussions with potential decision makers to facilitate a more rapid transition of EIIs to full decarbonisation.
Investigation of Certain Mechanical and Magnetic Properties of a Stressed Low-carbon steel after corrosion in NaCl-water solution
Jun 2020
Publication
Atomic hydrogen produced by corrosion of a low-carbon steel in NaCl – Water solution may markedly affect its certain tensile mechanical and magnetic properties in a complex and peculiar manner. This influence was investigated by employing the intrinsic micromagnetic emission (ME)-response as well as tensile mechanical response of this ferromagnetic material and also by introduction a relevant measurement parameter of specific micromagnetic emission response. In this fashion it was shown that an increase in the hydrogen accumulation with corrosion time leads to an associated increase in the pervasive and embrittling influence expressed by a marked loss in ductility of the material. It was also shown that the competitive interplay of cumulative hydrogen applied stress and plastic strain-induced microstructural damage was related to a specific ME-response parameter by which an increased magnetic hardening tendency of material with corrosion time was established. In general embrittlement and magnetic hardening are parallel products of stress- assisted hydrogen accumulation where magnetic hardening process seems to be in a time processing advance of embrittlement one. The above findings allow to estimate that the magnetic properties are more susceptible to hydrogen effects than the mechanical ones.
CFD Simulations of Hydrogen Release and Dispersion Inside the Storage Room of a Hydrogen Refuelling Station Using the ADREA-HF Code
Sep 2007
Publication
The paper presents CFD simulations of high pressure hydrogen release and dispersion inside the storage room of realistic hydrogen refuelling station and comparison to experimental data. The experiments were those reported by Tanaka et al. (2005) carried out inside an enclosure 5 m wide 6 m long and 4 m high having 1 m high ventilation opening on all sidewalls (half or fully open) containing an array of 35 x 250 L cylinders. The scenarios investigated were 40 MPa storage pressure horizontal releases from the center of the room from one cylinder with orifices of diameters 0.8 1.6 and 8 mm. The release calculations were performed using GAJET integral code. The CFD dispersion simulations were performed using the ADREA-HF CFD code. The structure of the flow and the mixing patterns were also investigated by presenting the predicted hydrogen concentration field. Finally the effects of release parameters natural ventilation and wind conditions were analyzed too.
Results of the HySafe CFD Validation Benchmark SBEPV5
Sep 2007
Publication
The different CFD tools used by the NoE HySafe partners are applied to a series of integral complex Standard Benchmark Exercise Problems (SBEPs). All benchmarks cover complementarily physical phenomena addressing application relevant scenarios and refer to associated experiments with an explicit usage of hydrogen. After the blind benchmark SBEPV1 and SBEPV3 with subsonic vertical release in a large vessel and in a garage like facility SBEPV4 with a horizontal under-expanded jet release through a small nozzle SBEPV5 covers the scenario of a subsonic horizontal jet release in a multi-compartment room.<br/>As the associated dispersion experiments conducted by GEXCON Norsk Hydro and STATOIL were disclosed to the participants the whole benchmark was conducted openly. For the purpose of validation only the low momentum test D27 had to be simulated.<br/>The experimental rig consists of a 1.20 m x 0.20 m x 0.90 m (Z vertical) vessel divided into 12 compartments partially even physically by four baffle plates. In each compartment a hydrogen concentration sensor is mounted. There is one vent opening at the wall opposite the release location centrally located about 1 cm above floor with dimensions 0.10 m (Y) times 0.20 m (Z). The first upper baffle plate close to the release point is on a sensitive location as it lies nearly perfectly in the centre of the buoyant jet and thus separates the flow into the two compartments. The actual release was a nominally constant flow of 1.15 norm liters for 60 seconds. With a 12mm nozzle diameter this corresponds to an average exit velocity of 10.17 m/s.<br/>6 CFD packages have been applied by 7 HySafe partners to simulate this experiment: ADREAHF by NCSRD FLACS by GexCon and DNV KFX by DNV FLUENT by UPM and UU CFX by HSE/HSL and GASFLOW by FZK. The results of the different participants are compared against the experimental data. Sensitivity studies were conducted by FZK using GASFLOW and by DNV applying KFX.<br/>Conclusions based on the comparisons and the sensitivity studies related to the performance of the applied turbulence models and discretisation schemes in the release and diffusion phase are proposed. These are compared to the findings of the previous benchmark exercises.
Numerical Studies of Dispersion and Flammable Volume of Hydrogen in Enclosures
Sep 2007
Publication
Hydrogen dispersion in an enclosure is numerically studied using simple analytical solutions and a large-eddy-simulation based CFD code. In simple calculations the interface height and temperature rise of the upper layer are obtained based on mass and energy conservation and the centreline hydrogen volume fraction is derived from similarity solutions of buoyant jets. The calculated centreline hydrogen volume fraction using the two methods agree with each other; however discrepancies are found for the calculated total flammable volume as a result of the inability of simple calculations in taking into account local mixing and diffusion. The CFD model in contrast is found to be capable of correctly reproducing the diffusion and stratification phenomena during the mixing stage.
An Intercomparison Exercise on the Capabilities of CFD Models to Predict Distribution and Mixing of H2 in a Closed Vessel.
Sep 2005
Publication
This paper presents a compilation and discussion of the results supplied by HySafe partners participating in the Standard Benchmark Exercise Problem (SBEP) V1 which is based on an experiment on hydrogen release mixing and distribution inside a vessel. Each partner has his own point of view of the problem and uses a different approach to the solution. The main characteristics of the models employed for the calculations are compared. The comparison between results together with the experimental data when available is made. Relative deviations of each model from the experimental values are also included. Explanations and interpretations of the results are presented together with some useful conclusions for future work.
No more items...