Skip to content
1900

CFD Validation Against Large Scale Liquified Helium Release

Abstract

The ADREA-HF CFD code is validated against a large scale liquefied helium release experiment on flat ground performed by INERIS in the past. The predicted release and dispersion behavior is evaluated against the experimental using temperature time histories at sensors deployed at various distances and heights downstream the source. For the selected sensors the temperature predictions are generally in good agreement with the experimental with a tendency to under-predict temperature as the source is approached.

Related subjects: Safety
Countries: France ; Greece
Loading

Article metrics loading...

/content/conference952
2019-09-25
2024-04-23
http://instance.metastore.ingenta.com/content/conference952
Loading

Supplements

CFD validation against large scale liquified helium release

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error