Safety
Dynamic Load Analysis of Explosion in Inhomogeneous Hydrogen-air Mixtures
Sep 2017
Publication
This paper presents results from experiments on gas explosions in inhomogeneous hydrogen-air mixtures. The experimental channel is 3 m with a cross section of 100 mm by 100 mm and a 0.25 mm ID nozzle for hydrogen release into the channel. The channel is open in one end. Spectral analysis of the pressure in the channel is used to determine dynamic load factors for SDOF structures. The explosion pressures in the channel will fluctuate with several frequencies or modes and a theoretical high DLF is seen when the pressure frequencies and eigen frequencies of the structure matches.
A Dual Zone Thermodynamic Model for Refueling Hydrogen Vehicles
Sep 2017
Publication
With the simple structure and quick refuelling process the compressed hydrogen storage system is currently widely used. However thermal effects during charging-discharging cycle may induce temperature change in storage tank which has significant impact on the performance of hydrogen storage and the safety of hydrogen storage tank. To address this issue we once propose a single zone lumped parameter model to obtain the analytical solution of hydrogen temperature and use the analytical solution to estimate the hydrogen temperature but the effect of the tank wall is ignored. For better description of the heat transfer characteristics of the tank wall a dual zone (hydrogen gas and tank wall) lumped parameter model will be considered for widely representation of the reference (experimental or simulated) data. Now we extend the single zone model to the dual zone model which uses two different temperatures for gas zone and wall zone. The dual zone model contains two coupled differential equations. To solve them and obtain the solution we use the method of decoupling the coupled differential equations and coupling the solutions of the decoupled differential equations. The steps of the method include: (1) Decoupling of coupled differential equations; (2) Solving decoupled differential equations; (3) Coupling of solutions of differential equations; (4) Solving coupled algebraic equations. Herein three cases are taken into consideration: constant inflow/outflow temperature variable inflow/outflow temperature and constant inflow temperature and variable outflow temperature. The corresponding approximate analytical solutions of hydrogen temperature and wall temperature can be obtained. The hydrogen pressure can be calculated from the hydrogen temperature and the hydrogen mass using the equation of state for ideal gas. Besides the two coupled differential equations can also be solved numerically and the simulated solution can also be obtained. This study will help to set up a formula based approach of refuelling protocol for gaseous hydrogen vehicles.
Optimizing Mixture Properties for Accurate Laminar Flame Speed Measurement from Spherically Expanding Flame: Application to H2/O2/N2/He Mixtures
Sep 2019
Publication
The uncertainty on the laminar flame speed extracted from spherically expanding flames can be minimized by using large flame radius data for the extrapolation to zero stretch-rate. However at large radii the hydrodynamic and thermo-diffusive instabilities induce the formation of a complex cellular flame front and limit the range of usable data. In the present study we have employed the flame stability theory of Matalon to optimize the properties of the initial mixture so that transition to cellularity may occur at a pre-determined large radius. This approach was employed to measure the laminar flame speeds of H2/O2/N2/He mixtures with equivalence ratios from 0.6 to 2.0 at pressures of 50/80/100 kPa and a temperature of 300 K. For all the performed experiments the uncertainty related to the extrapolation to zero stretch-rate (performed with the linear curvature model) was below 2% as shown by the position of the data points in the (Lb/Rf;U Lb/Rf;L) plan where Lb is the burned Markstein length; and Rf;L and Rf;U are the flame radii at the lower and upper bounds of the extrapolation range. Comparison of the predictions of four chemical mechanisms with the present unstretched laminar flame speed data indicated an error below 10% for most conditions. In addition unsteady 1-D simulations performed with A-SURF demonstrated that the flame dynamical response to stretch rate could not be captured by the mechanisms. The present work indicates that although the stability theory of Matalon provides a well defined framework to optimize the mixture properties for improved flame speed measurement the uncertainty of some of the required parameters can result in largely over-estimated critical radius for cellularity onset which compromise the accuracy of the optimization procedure.
Risk Informed Separation Distances For Hydrogen Refuelling Stations
Sep 2011
Publication
The lay-out requirements developed for hydrogen systems operated in industrial environment are not suitable for the operating conditions specific to hydrogen refuelling stations (service pressure of up to 95 MPa facility for public use). A risk informed rationale has been developed to define and substantiate separation distance requirements in ISO 20100 Gaseous hydrogen – refuelling stations [1]. In this approach priority is given to preventing escalation of small incidents into majors ones with a focus on critical exposures such as places of occupancy (fuelling station retail shop) while optimizing use of the available space from a risk perspective a key objective for being able to retrofit hydrogen refuelling in existing stations.
Cell Failure Mechanisms in PEM Water Electrolyzers
Sep 2011
Publication
PEM water electrolysis offers an efficient and flexible way to produce “green-hydrogen” from renewable (intermittent) energy sources. Most research papers published in the open literature on the subject are addressing performances issues and to date very few information is available concerning the mechanisms of performance degradation and the associated consequences. Results reported in this communication have been used to analyze the failure mechanisms of PEM water electrolysis cells which can ultimately lead to the destruction of the electrolyzer. A two-step process involving firstly the local perforation of the solid polymer electrolyte followed secondly by the catalytic recombination of hydrogen and oxygen stored in the electrolysis compartments has been evidenced. The conditions leading to the onset of such mechanism are discussed and some preventive measures are proposed to avoid accidents.
Regulations, Codes, and Standards (RCS) for Multi-fuel Motor Vehicle Dispensing Station
Sep 2017
Publication
In the United States requirements for liquid motor vehicle fuelling stations have been in place for many years. Requirements for motor vehicle fuelling stations for gaseous fuels including hydrogen are relatively new. These requirements have in the United States been developed along different code and standards paths. The liquid fuels have been addressed in a single document and the gaseous fuels have been addressed in documents specific to an individual gas. The result of these parallel processes is that multi-fuel stations are subject to requirements in several fuelling regulations codes and standards (RCS). This paper describes a configuration of a multi-fuel motor vehicle fuelling station and provides a detailed breakdown of the codes and standards requirements. The multi-fuel station would dispense what the U.S. Department of Energy defines as the six key alternative fuels: biodiesel electricity ethanol hydrogen natural gas and propane. The paper will also identify any apparent gaps in RCS and potential research projects that could help fill these gaps.
Assessment of Safety for Hydrogen Fuel Cell Vehicle
Sep 2011
Publication
A prospective global market share of Electric vehicle (EV) Hybrid electric vehicle (HEV) and Hydrogen Fuel Cell Vehicle (HFCV) is expected to grow due to stringent emission regulation and oil depletion. However it is essential to secure protection against high-pressure hydrogen gas and high-voltage in fuel cell vehicles and thus needs to develop a technique for safety assessment of HFCV. In this experiment 8 research institutes including the Korea Automobile Testing and Research Institute Hyundai Motor Company took part in. This project was supported by the Ministry of Land Transportation and Maritime Affairs of the Republic of Korea.
Effect of Rotation on Ignition Thresholds of Stoichiometric Hydrogen Mixtures
Sep 2017
Publication
Successful transition to a hydrogen economy calls for a deep understanding of the risks associated with its widespread use. Accidental ignition of hydrogen by hot surfaces is one of such risks. In the present study we investigated the effect that rotation has on the reported ignition thresholds by numerically determining the minimum surface temperature required to ignite stoichiometric hydrogen-air using a hot horizontal cylinder rotating at various angular velocities ω. Numerical experiments showed a weak but interesting dependence of the ignition thresholds on rotation: the ignition thresholds increased by 8 K from 931 K to 939 K with increasing angular velocity (0 ≤ ω ≤ 240 rad/s). A further increase to ω = 480 rad/s resulted in a decrease in ignition surface temperature to 935 K. Detailed analysis of the flow patterns inside the vessel and in close proximity to the hot surface brought about by the combined effect of buoyancy and rotation as well as of the distribution of the wall heat flux along the circumference of the cylinder support our previous findings in which regions where temperature gradients are small were found to be prone to ignition.
The Residual Strength of Automotive Hydrogen Cylinders After Exposure to Flames
Sep 2017
Publication
Fuel cell vehicles and some compressed natural gas vehicles are equipped with carbon fiber reinforced plastic (CFRP) composite cylinders. Each of the cylinders has a pressure relief device designed to detect heat and release the internal gas to prevent the cylinder from bursting in a vehicle fire accident. Yet in some accident situations the fire may be extinguished before the pressure relief device is activated leaving the high-pressure fuel gas inside the fire-damaged cylinder. To handle such a cylinder safely after an accident it is necessary that the cylinder keeps a sufficient post-fire strength against its internal gas pressure but in most cases it is difficult to accurately determine cylinder strength at the accident site. One way of solving this problem is to predetermine the post-fire burst strengths of cylinders by experiments. In this study automotive CFRP cylinders having no pressure relief device were exposed to a fire to the verge of bursting; then after the fire was extinguished the residual burst strengths and the overall physical state of the test cylinders were examined. The results indicated that the test cylinders all recorded a residual burst strength at least twice greater than their internal gas pressure for tested cylinders with new cylinder burst to nominal working pressure in the range 2.67–4.92 above the regulated ratio of 2.25.
Experiments on the Combustion Behaviour of Hydrogen-Carbon Monoxide-Air Mixtures
Sep 2019
Publication
As a part of a German nuclear safety project on the combustion behaviour of hydrogen-carbon monoxide-air mixtures small scale experiments were performed to determine the lower flammability limit and the laminar burning velocity of such mixtures. The experiments were performed in a spherical explosion bomb with a free volume of 8.2 litre. The experimental set-up is equipped with a central spark ignition and quartz glass windows for optical access. Further instrumentation included pressure and temperature sensors as well as high-speed shadow-videography. A wide concentration range for both fuel gases was investigated in numerous experiments from the lower flammability limits up to the stoichiometric composition of hydrogen carbon monoxide and air (H2-CO-air) mixtures. The laminar burning velocities were determined from the initial pressure increase after the ignition and by using high-speed videos taken during the experiments.
Data for the Evaluation of Hydrogen Risks Onboard Vehicles: Outcomes from the French Project Drive
Sep 2011
Publication
From 2006 to 2009 INERIS alongside with CEA PSA PEUGEOT CITROËN and IRPHE were involved in a project called DRIVE. Its objective was to provide data on the whole reaction chain leading to a hydrogen hazard onboard a vehicle. Out of the three types of leakage identified by the consortium (permeation chronic and accidental) the chronic leakage taking place within the engine was judged to be more problematic since it can feature a high probability of occurrence and a significant release flow rate (up to 100 NL/min). Ignition tests carried out within a real and dummy engine compartment showed that pressure effects due to an explosion will be relatively modest provided that the averaged hydrogen concentration in this area is limited to 10% vol/vol which would correspond to a maximum release flow of 10 NL/min. This maximum concentration could be used as a threshold value for detection or as a target while designing the vehicle. Jet fire experiments were also conducted in the frame of the DRIVE project. It was found that pressure-relief devices (PRDs) might be unsuited to protect humans from the explosion of a tank caused by a bonfire. Other solutions are proposed in this paper.
Spontaneous Ignition Processes Due To High-Pressure Hydrogen Release in Air
Sep 2011
Publication
Spontaneous ignition processes due to the high-pressure hydrogen releases into air were investigated both experimentally and theoretically. Such processes reproduce accident scenarios of sudden expansion of pressurized hydrogen into the ambient atmosphere in cases of tube or valve rupture. High-pressure hydrogen releases in the range of initial pressures from 20 to 275 bar and with nozzle diameters of 0.5 – 4 mm have been investigated. Glass tubes and high-speed CCD camera were used for experimental study of self-ignition process. The problem was theoretically considered in terms of contact discontinuity for the case when spontaneous ignition of pressurized hydrogen due to the contact with hot pressurized air occurs. The effects of boundary layer and material properties are discussed in order to explain the minimum initial pressure of 25 bar leading to the self-ignition of hydrogen with air.
Experimental Study of Ignited Unsteady Hydrogen Jets into Air
Sep 2009
Publication
In order to simulate an accidental hydrogen release from the low pressure pipe system of a hydrogen vehicle a systematic study on the nature of transient hydrogen jets into air and their combustion behaviour was performed at the FZK hydrogen test site HYKA. Horizontal unsteady hydrogen jets with an amount of hydrogen up to 60 STP dm3 and initial pressures of 5 and 16 bar have been investigated. The hydrogen jets were ignited with different ignition times and positions. The experiments provide new experimental data on pressure loads and heat releases resulting from the deflagration of hydrogen-air clouds formed by unsteady turbulent hydrogen jets released into a free environment. It is shown that the maximum pressure loads occur for ignition in a narrow position and time window. The possible hazard potential arising from an ignited free transient hydrogen jet is described.
Use of Hydrogen Safety Sensors Under Anaerobic Conditions – Impact of Oxygen Content on Sensor Performance
Sep 2011
Publication
In any application involving the production storage or use of hydrogen sensors are important devices for alerting to the presence of leaked hydrogen. Hydrogen sensors should be accurate sensitive and specific as well as resistant to long term drift and varying environmental conditions. Furthermore as an integral element in a safety system sensor performance should not be compromised by operational parameters. For example safety sensors may be required to operate at reduced oxygen levels relative to air. In this work we evaluate and compare a number of sensor technologies in terms of their ability to detect hydrogen under conditions of varying oxygen concentration.
Determination of Clearance Distances for Venting of Hydrogen Storage
Sep 2005
Publication
This paper discusses the results of computational fluid dynamics (CFD) modelling of hydrogen releases and dispersion outdoors during venting of hydrogen storage in real environment and geometry of a hydrogen refuelling or energy station for a given flow rate and dimensions of vent stack. The PHOENICS CFD software package was used to solve the continuity momentum and concentration equations with the appropriate boundary conditions buoyancy model and turbulence models. Also thermal effects resulting from potential ignition of flammable hydrogen clouds were assessed using TNO “Yellow Book” recommended approaches. The obtained results were then applied to determine appropriate clearance distances for venting of hydrogen storage for contribution to code development and station design considerations. CFD modelling of hydrogen concentrations and TNO-based modelling of thermal effects have proven to be reliable effective and relatively inexpensive tools to evaluate the effects of hydrogen releases.
Experimental Study of Vented Hydrogen Deflagration with Ignition Inside and Outside the Vented Volume
Sep 2013
Publication
Experiments were carried out inside a 25 m3 vented combustion test facility (CVE) with a fixed vent area sealed by a plastic sheet vent. Inside the CVE a 0.64 m3 open vent box called RED-CVE was placed. The vent of the RED-CVE was left open and three different vent area were tested. Two different mixing fans one for each compartment were used to establish homogeneous H2 concentrations. This study examined H2 concentrations in the range between 8.5% vol. to 12.5% vol. and three different ignition locations (1) far vent ignition (2) inside the RED-CVE box ignition and (3) near vent ignition (the vent refers to the CVE vent). Peak overpressures generated inside the test facility and the smaller compartment were measured. The results indicate that the near vent ignition generates negligible peak overpressures inside the test facility as compared to those originated by far vent ignition and ignition inside the RED-CVE box. The experiments with far vent ignition showed a pressure increase with increasing hydrogen concentration which reached a peak value at 11% vol. concentration and then decreased showing a non-monotonic behaviour. The overpressure measured inside the RED-CVE was higher when the ignition was outside the box whereas the flame entered the box through the small vent.
Experimental Investigation of Hydrogen Jet Fire Mitigation by Barrier Walls
Sep 2009
Publication
Hydrogen jet flames resulting from ignition of unintended releases can be extensive in length and pose significant radiation and impingement hazards. One possible mitigation strategy to reduce exposure to jet flames is to incorporate barriers around hydrogen storage and delivery equipment. While reducing the extent of unacceptable consequences the walls may introduce other hazards if not properly configured. This paper describes experiments carried out to characterize the effectiveness of different barrier wall configurations at reducing the hazards created by jet fires. The hazards that are evaluated are the generation of overpressure during ignition the thermal radiation produced by the jet flame and the effectiveness of the wall at deflecting the flame.<br/>The tests were conducted against a vertical wall (1-wall configuration) and two “3-wall” configurations that consisted of the same vertical wall with two side walls of the same dimensions angled at 135° and 90°. The hydrogen jet impinged on the center of the central wall in all cases. In terms of reducing the radiation heat flux behind the wall the 1-wall configuration performed best followed by the 3-wall 135° configuration and the 3-wall 90°. The reduced shielding efficiency of the three-wall configurations was probably due to the additional confinement created by the side walls that limited the escape of hot gases to the sides of the wall and forced the hot gases to travel over the top of the wall.<br/>The 3-wall barrier with 135° side walls exhibited the best overall performance. Overpressures produced on the release side of the wall were similar to those produced in the 1-wall configuration. The attenuation of overpressure and impulse behind the wall was comparable to that of the three-wall configuration with 90° side walls. The 3-wall 135° configuration’s ability to shield the back side of the wall from the heat flux emitted from the jet flame was comparable to the 1-wall and better than the 3-wall 90° configuration. The ratio of peak overpressure (from in front of the wall and from behind the wall) showed that the 3-wall 135° configuration and the 3-wall 90° configuration had a similar effectiveness. In terms of the pressure mitigation the 3-wall configurations performed significantly better than the 1-wall configuration
Safety Demands for Automotive Hydrogen Storage Systems
Sep 2005
Publication
Fuel storage systems for vehicles require a fail-safe design strategy. In case of system failures or accidents the control electronics have to switch the system into a safe operation mode. Failure Mode and Effect Analysis (FMEA) or Failure Tree Analysis (FTA) are performed already in the early design phase in order to minimize the risk of design failures in the fuel storage system. Currently the specifications of requirements for pressurized and liquid hydrogen fuel tanks are based on draft UN-ECE Regulations developed by the European Integrated Hydrogen Project (EIHP). Used materials and accessories shall be compatible with hydrogen. A selection of metallic and non-metallic materials will be presented. Complex components have to be optimised by FEM simulations in order to determine weak spots in the design which will be overstressed in case of pressure thermal expansion or dynamic vibrations. According to automotive standards the performance of liquid hydrogen fuel tank systems has to be verified in various destructive and non-destructive tests.
Safety of Hydrogen-fueled Motor Vehicles with IC Engines.
Sep 2005
Publication
Clarification of questions of safety represents a decisive contribution to the successful introduction of vehicles fuelled by hydrogen. At the moment the safety of hydrogen is being discussed and investigated by various bodies. The primary focus is on fuel-cell vehicles with hydrogen stored in gaseous form. This paper looks at the safety of hydrogen-fuelled vehicles with an internal combustion engine and liquefied hydrogen storage. The safety concept of BMW’s hydrogen vehicles is described and the specific aspects of the propulsion and storage concepts discussed. The main discussion emphasis is on the utilization of boil-off parking of the vehicles in an enclosed space and their crash behaviour. Theoretical safety observations are complemented by the latest experimental and test results. Finally reference is made to the topic-areas in the field of hydrogen safety in which cooperative research work could make a valuable contribution to the future of the hydrogen-powered vehicle.
CFD Computations of Liquid Hydrogen Releases
Sep 2011
Publication
Hydrogen is widely recognized as an attractive energy carrier due to its low-level air pollution and its high mass-related energy density. However its wide flammability range and high burning velocity present a potentially significant hazard. A significant fraction of hydrogen is stored and transported as a cryogenic liquid (liquid hydrogen or LH2) as it requires much less volume compared to gaseous hydrogen. In order to exist as a liquid H2 must be cooled to a very low temperature 20.28 K. LH2 is a common liquid fuel for rocket applications. It can also be used as the fuel storage in an internal combustion engine or fuel cell for transport applications. Models for handling liquid releases both two-phase flashing jets and pool spills have been developed in the CFD-model FLACS. The very low normal boiling point of hydrogen (20 K) leads to particular challenges as this is significantly lower than the boiling points of oxygen (90 K) and nitrogen (77 K). Therefore a release of LH2 in the atmosphere may induce partial condensation or even freezing of the oxygen and nitrogen present in the air. A pool model within the CFD software FLACS is used to compute the spreading and vaporization of the liquid hydrogen depositing on the ground where the partial condensation or freezing of the oxygen and nitrogen is also taken into account. In our computations of two-phase jets the dispersed and continuous phases are assumed to be in thermodynamic and kinematic equilibrium. Simulations with the new models are compared against selected experiments performed at the Health and Safety Laboratory (HSL).
No more items...