Greece
Sizing, Optimization, and Financial Analysis of a Green Hydrogen Refueling Station in Remote Regions
Jan 2022
Publication
Hydrogen (H2 ) can be a promising energy carrier for decarbonizing the economy and especially the transport sector which is considered as one of the sectors with high carbon emissions due to the extensive use of fossil fuels. H2 is a nontoxic energy carrier that could replace fossil fuels. Fuel Cell Electric Vehicles (FCEVs) can decrease air pollution and reduce greenhouse gases when H2 is produced from Renewable Energy Sources (RES) and at the same time being accessible through a widespread network of Hydrogen Refueling Stations (HRSs). In this study both the sizing of the equipment and financial analysis were performed for an HRS supplied with H2 from the excess electrical energy of a 10 MW wind park. The aim was to determine the optimum configuration of an HRS under the investigation of six different scenarios with various numbers of FCEVs and monthly demands as well as ascertaining the economic viability of each examined scenario. The effect of the number of vehicles that the installation can refuel to balance the initial cost of the investment and the fuel cost in remote regions was investigated. The results showed that a wind-powered HRS could be a viable solution when sized appropriately and H2 can be used as a storage mean for the rejected wind energy. It was concluded that scenarios with low FCEVs penetration have low economic performance since the payback period presented significantly high values.
Status of the Pre-normative Research Project PRESLHY for the Safe Use of LH2
Sep 2019
Publication
Liquid hydrogen (LH2) compared to compressed gaseous hydrogen offers advantages for large scale transport and storage of hydrogen with higher densities and potentially better safety performance. Although the gas industry has good experience with LH2 only little experience is available for the new applications of LH2 as an energy carrier. Therefore the European FCH JU funded project PRESLHY conducts pre-normative research for the safe use of cryogenic LH2 in non-industrial settings. The work program consists of a preparatory phase where the state of the art before the project has been summarized and where the experimental planning was adjusted to the outcome of a research priorities workshop. The central part of the project consists of 3 phenomena oriented work packages addressing Release Ignition and Combustion with analytical approaches experiments and simulations. The results shall improve the general understanding of the behavior of LH2 in accidents and thereby enhance the state-of-the-art what will be reflected in appropriate recommendations for development or revision of specific international standards. The paper presents the status of the project at the middle of its terms.
Evaluation of the ADREA-HF CFD Code Against a Hydrogen Deflagration in a Tunnel
Sep 2013
Publication
In the present work the capabilities of the computational fluid dynamics (CFD) code ADREA-HF to predict deflagration in homogenous near stoichiometric hydrogen-air mixture in a model of a tunnel were tested. The tunnel is 78.5 m long. Hydrogen-air mixture is located in a 10 m long region in the middle of the tunnel. Two cases are studied: one with a complete empty tunnel and one with the presence of four vehicles near the center of the tunnel. The combustion model is based on the turbulent flame speed concept. The turbulent flame speed is a modification of Yakhot's equation in order to account for additional physical mechanisms. A sensitivity analysis for the parameter of the combustion model and for the mesh resolution was made for the empty tunnel case. The agreement between experimental and computational results concerning the value of the maximum pressure and the time it appears is satisfactory in both cases. The sensitivity analysis for the parameter of the combustion model showed that even small changes in it can have impact on the simulating results whereas the sensitivity analysis of the mesh resolution did not reveal any significant differences.
Modeling of Cryogenic Hydrogen jets
Oct 2015
Publication
In the present work the CFD modeling of cryogenic hydrogen releases in quiescent environment is presented. Two tests from the series of experiments performed in the ICESAFE facility at KIT (Karlsruhe Institute for Technology) have been simulated within the SUSANA project. During these tests hydrogen at temperature of 37K and 36K and at pressure of 19 and 29 bars respectively is released horizontally. The release at the nozzle is sonic and the modeling of the under-expanded jet was performed using two different approaches: the Ewan and Moodie approach and a modification of the Ewan and Moodie approach (modified Ewan and Moodie) that is introduced here and employs the momentum balance to calculate the velocity in the under-expanded jet. Using these approaches a pseudo-diameter is calculated and this diameter is set as source boundary in the simulation. Predictions are consistent with measurements for both experiments with both approaches. However the Ewan and Moodie approach seems to perform better.
Methanol Reforming Processes for Fuel Cell Applications
Dec 2021
Publication
Hydrogen production through methanol reforming processes has been stimulated over the years due to increasing interest in fuel cell technology and clean energy production. Among different types of methanol reforming the steam reforming of methanol has attracted great interest as reformate gas stream where high concentration of hydrogen is produced with a negligible amount of carbon monoxide. In this review recent progress of the main reforming processes of methanol towards hydrogen production is summarized. Different catalytic systems are reviewed for the steam reforming of methanol: mainly copper- and group 8–10-based catalysts highlighting the catalytic key properties while the promoting effect of the latter group in copper activity and selectivity is also discussed. The effect of different preparation methods different promoters/stabilizers and the formation mechanism is analyzed. Moreover the integration of methanol steam reforming process and the high temperature–polymer electrolyte membrane fuel cells (HT-PEMFCs) for the development of clean energy production is discussed.
CFD Modeling OF LH2 Dispersion Using the ADREA-HF Code
Sep 2011
Publication
In the present work the computational fluid dynamics (CFD) code ADREA-HF has been applied to simulate the very recent liquefied hydrogen spill experiments performed by the Health Safety Laboratory (HSL). The experiment consists of four LH2 release trials over concrete at a fixed rate of 60 lt/min but with different release direction height and duration. In the modeling the hydrogen source was treated as a two phase jet enabling simultaneous modeling of pool formation spreading as well as hydrogen vapor dispersion. Turbulence was modeled with the standard k- model modified for buoyancy effects. The effect of solidification of the atmospheric humidity was taken into account. The predicted concentration at the experimental sensors? locations was compared with the observed one. The results from the comparison of the predicted concentration with and without solidification of the atmospheric humidity indicate that the released heat from the solidification affects significantly the buoyant behavior of the hydrogen vapor. Therefore the simulation with solidification of the atmospheric humidity is in better agreement with the experiment.
Evaluation of an Improved Vented Deflagration CFD Model Against Nine Experimental Cases
Sep 2019
Publication
In the present work a newly developed CFD deflagration model incorporated into the ADREA-HF code is evaluated against hydrogen vented deflagrations experiments carried out by KIT and FM-Global in a medium (1 m3) and a real (63.7 m3) scale enclosure respectively. A square vent of 0.5 m2 and 5.4 m2 respectively is located in the center of one of side walls. In the case of the medium scale enclosure the 18% v/v homogeneous hydrogen-air mixture and back-wall ignition case is examined. In the case of the real scale enclosure the examined cases cover different homogeneous mixture concentrations (15% and 18% v/v) different ignition locations (back-wall and center) and different levels of initial turbulence. The CFD model accounts for flame instabilities that develop as the flame propagates inside the chamber and turbulence that mainly develops outside the vent. Pressure predictions are compared against experimental measurements revealing a very good performance of the CFD model for the back-wall ignition cases. For the center ignition cases the model overestimates the maximum overpressure. The opening of the vent cover is identified as a possible reason for the overprediction. The analysis indicates that turbulence is the main factor which enhances external explosion strength causing the sudden pressure increase confirming previous findings.
Methodology for the Development of Hybrid Renewable Energy Systems (HRES) with Pumped Storage and Hydrogen Production on Lemnos Island
Apr 2022
Publication
The non-interconnected islands of Greece can benefit from the comprehensive use of RES to avoid water droughts and ensure energy autonomy. The present paper analyzes an HRES with two possible operating scenarios. Both of them include a wind park of 27.5 MW capacity an 1175 m3/day desalination plant and a 490000 m3/day water tank in Lemnos Greece. Regarding the wind power 70% is used in the HRES while the rest is channeled directly to the grid. The main difference comes down to how the wind energy is stored either in the form of hydraulic energy or in the form of hydrogen. The lifespan of the system is 25 years such as the produced stochastic series of rainfall temperature and wind of the area. Through the comparison of the operating scenarios the following results arise: (i) the water needs of the island are fully covered and the irrigation needs have a reliability of 66% in both scenarios. (ii) Considering the energy needs the pumping storage seems to be the most reliable solution. (iii) However depending on the amount of wind energy surplus the use of hydrogen could produce more energy than the hydroelectric plant.
CFD Modeling for Helium Releases in a Private Garage Without Forced Ventilation.
Sep 2005
Publication
In the course towards a safe future hydrogen based society one of the tasks to be considered is the investigation of the conditions under which the use or storage of hydrogen systems inside buildings becomes too dangerous to be accepted. One of the relevant scenarios which is expected to have a relatively high risk is a slow (and long lasting) hydrogen release from a vehicle stored in a closed private garage without any forced ventilation i.e. only with natural ventilation. This scenario has been earlier investigated experimentally (by M. Swain) using He (helium) to simulate the hydrogen behavior. In the present work the CFD code ADREA-HF is used to simulate three of the abovementioned experiments using the standard k- turbulence model. For each case modeled the predicted concentration (by vol.) time series are compared against the experimental at the given sensor locations. In addition the structure of the flow is investigated by presenting the helium concentration field.
Best Practice in Numerical Simulation and CFD Benchmarking. Results from the SUSANA Project
Sep 2017
Publication
Correct use of Computational Fluid Dynamics (CFD) tools is essential in order to have confidence in the results. A comprehensive set of Best Practice Guidelines (BPG) in numerical simulations for Fuel Cells and Hydrogen applications has been one of the main outputs of the SUSANA project. These BPG focus on the practical needs of engineers in consultancies and industry undertaking CFD simulations or evaluating CFD simulation results in support of hazard/risk assessments of hydrogen facilities as well as on the needs of regulatory authorities. This contribution presents a summary of the BPG document. All crucial aspects of numerical simulations are addressed such as selection of the physical models domain design meshing boundary conditions and selection of numerical parameters. BPG cover all hydrogen safety relative phenomena i.e. release and dispersion ignition jet fire deflagration and detonation. A series of CFD benchmarking exercises are also presented serving as examples of appropriate modelling strategies.
On the Use of Hydrogen in Confined Spaces: Results from the Internal Project InsHyde
Sep 2009
Publication
Alexandros G. Venetsanos,
Paul Adams,
Inaki Azkarate,
A. Bengaouer,
Marco Carcassi,
Angunn Engebø,
E. Gallego,
Olav Roald Hansen,
Stuart J. Hawksworth,
Thomas Jordan,
Armin Keßler,
Sanjay Kumar,
Vladimir V. Molkov,
Sandra Nilsen,
Ernst Arndt Reinecke,
M. Stöcklin,
Ulrich Schmidtchen,
Andrzej Teodorczyk,
D. Tigreat,
N. H. A. Versloot and
L. Boon-Brett
The paper presents an overview of the main achievements of the internal project InsHyde of the HySafe NoE. The scope of InsHyde was to investigate realistic small-medium indoor hydrogen leaks and provide recommendations for the safe use/storage of indoor hydrogen systems. Additionally InsHyde served to integrate proposals from HySafe work packages and existing external research projects towards a common effort. Following a state of the art review InsHyde activities expanded into experimental and simulation work. Dispersion experiments were performed using hydrogen and helium at the INERIS gallery facility to evaluate short and long term dispersion patterns in garage like settings. A new facility (GARAGE) was built at CEA and dispersion experiments were performed there using helium to evaluate hydrogen dispersion under highly controlled conditions. In parallel combustion experiments were performed by FZK to evaluate the maximum amount of hydrogen that could be safely ignited indoors. The combustion experiments were extended later on by KI at their test site by considering the ignition of larger amounts of hydrogen in obstructed environments outdoors. An evaluation of the performance of commercial hydrogen detectors as well as inter-lab calibration work was jointly performed by JRC INERIS and BAM. Simulation work was as intensive as the experimental work with participation from most of the partners. It included pre-test simulations validation of the available CFD codes against previously performed experiments with significant CFD code inter-comparisons as well as CFD application to investigate specific realistic scenarios. Additionally an evaluation of permeation issues was performed by VOLVO CEA NCSRD and UU by combining theoretical computational and experimental approaches with the results being presented to key automotive regulations and standards groups. Finally the InsHyde project concluded with a public document providing initial guidance on the use of hydrogen in confined spaces.
Comparison of Convective Schemes in Hydrogen Impinging Jet CFD Simulation
Oct 2015
Publication
Hydrogen impinging jets can be formed in the case of an accidental release indoors or outdoors. The CFD simulation of hydrogen impinging jets suffers from numerical errors resulting in a non-physical velocity and hydrogen concentration field with a butterfly like structure. In order to minimize the numerical errors and to avoid the butterfly effect high order schemes need to be used. The aim of this work is to give best practices guidelines for hydrogen impinging jet simulations. A number of different numerical schemes is evaluated. The number of cells which discretize the source is also examined.
Hysafe SBEP-V20: Numerical Predictions of Release Experiments Inside a Residential Garage With Passive Ventilation
Sep 2009
Publication
This work presents the results of the Standard Benchmark Exercise Problem (SBEP) V20 of Work Package 6 (WP6) of HySafe Network of Excellence (NoE) co-funded by the European Commission in the frame of evaluating the quality and suitability of codes models and user practices by comparative assessments of code results. The benchmark problem SBEP-V20 covers release scenarios that were experimentally investigated in the past using helium as a substitute to hydrogen. The aim of the experimental investigations was to determine the ventilation requirements for parking hydrogen fuelled vehicles in residential garages. Helium was released under the vehicle for 2 h with 7.200 l/h flow rate. The leak rate corresponded to a 20% drop of the peak power of a 50 kW fuel cell vehicle. Three double vent garage door geometries are considered in this numerical investigation. In each case the vents are located at the top and bottom of the garage door. The vents vary only in height. In the first case the height of the vents is 0.063 m in the second 0.241 m and in the third 0.495 m. Four HySafe partners participated in this benchmark. The following CFD packages with the respective models were applied to simulate the experiments: ADREA-HF using k–ɛ model by partner NCSRD FLACS using k–ɛ model by partner DNV FLUENT using k–ɛ model by partner UPM and CFX using laminar and the low-Re number SST model by partner JRC. This study compares the results predicted by the partners to the experimental measurements at four sensor locations inside the garage with an attempt to assess and validate the performance of the different numerical approaches.
Estimation of an Allowable Hydrogen Permeation Rate From Road Vehicle Compressed Gaseous H2 Storage Systems In Typical Garages, Part 2: CFC Dispersion Calculations Using the ADREA-HF Code and Experimental Validation Using Helium Tests at the Garage Facility
Sep 2009
Publication
The time and space evolution of the distribution of hydrogen in confined settings was investigated computationally and experimentally for permeation from typical compressed gaseous hydrogen storage systems for buses or cars. The work was performed within the framework of the InsHyde internal project of the HySafe NoE funded by EC. The main goal was to examine whether hydrogen is distributed homogeneously within a garage like facility or whether stratified conditions are developed under certain conditions. The nominal hydrogen flow rate considered was 1.087 NL/min based on the then current SAE standard for composite hydrogen containers with a non-metallic liner (type 4) at simulated end of life and maximum material temperature in a bus facility with a volume of 681m3. The release was assumed to be directed upwards from a 0.15m diameter hole located at the middle part of the bus cylinders casing. Ventilation rates up to 0.03 ACH were considered. Simulated time periods extended up to 20 days. The CFD simulations performed with the ADREA-HF code showed that fully homogeneous conditions exist for low ventilation rates while stratified conditions prevail for higher ventilation rates. Regarding flow structure it was found that the vertical concentration profiles can be considered as the superposition of the concentration at the floor (driven by laminar diffusion) plus a concentration difference between floor and ceiling (driven by buoyancy forces). In all cases considered this concentration difference was found to be less than 0.5%. The dispersion experiments were performed at the GARAGE facility using Helium. Comparison between CFD simulations and experiments showed that the predicted concentrations were in good agreement with the experimental data. Finally simulations were performed using two integral models: the fully homogeneous model and the two-layer model proposed by Lowesmith et al. (ICHS-2 2007) and the results were compared both against CFD and the experimental data.
A Reappraisal of Containment Safety Under Hydrogen Detonation
Sep 2005
Publication
The response of a typical steel-lined reinforced concrete nuclear reactor containment to postulated internal hydrogen detonations is investigated by detailed axisymetric non-linear dynamic finite element analysis. The wall pressure histories are calculated for hydrogen detonations using a technique that reproduces the sharp discontinuity at the shock front. The pressure results can be applied to geometrically similar vessels. The analysis indicates that the response is more sensitive to the point of initiation than to the strength of the detonation. Approximate solutions based on a pure impulse assumption where the containment is modelled as a single-degree-of freedom (SDOF) system may be seriously unconservative. This work becomes relevant because new nuclear reactors are foreseen as a primary of source of hydrogen supply.<br/><br/>
Consequence Assessment of the BBC Hydrogen Refuelling Station, Using The Adrea-Hf Code
Sep 2009
Publication
Within the framework of the internal project HyQRA of the HYSAFE Network of Excellence (NoE) funded by the European Commission (EC) the participating partners were requested to apply their Quantitative Risk Assessment (QRA) methodologies on a predefined hypothetical gaseous H2 refuelling station named BBC (Benchmark Base Case). The overall aim of the HyQRA project was to perform an inter-comparison of the various QRA approaches and to identify the knowledge gaps on data and information needed in the QRA steps specifically related to H2. Partners NCSRD and UNIPI collaborated on a common QRA. UNIPI identified the hazards on site selected the most critical ones defined the events that could be the primary cause of an accident and provided to NCSRD the scenarios listed in risk order for the evaluation of the consequences. NCSRD performed the quantitative analysis using the ADREA-HF CFD code. The predicted risk assessment parameters (flammable H2 mass and volume time histories and maximum horizontal and vertical distances of the LFL from the source) were provided to UNIPI to analyze the consequences and to evaluate the risk and distances of damage. In total 15 scenarios were simulated. Five of them were H2 releases in confined ventilated spaces (inside the compression and the purification/drying buildings). The remaining 10 scenarios were releases in open/semi-confined spaces (in the storage cabinet storage bank and refuelling hose of one dispenser). This paper presents the CFD methodology applied for the quantitative analysis of the common UNIPI/NCSRD QRA and discusses the results obtained from the performed calculations.
The Effect of Cold Rolling on the Hydrogen Susceptibility of 5083 Aluminium Alloy
Oct 2017
Publication
This work focuses in investigating the effect of cold deformation on the cathodic hydrogen charging of 5083 aluminum alloy. The aluminium alloy was submitted to a cold rolling process until the average thickness of the specimens was reduced by 7% and 15% respectively. A study of the structure microhardness and tensile properties of the hydrogen charged aluminium specimens with and without cold rolling indicated that the cold deformation process led to an increase of hydrogen susceptibility of this aluminum alloy.
Numerical Simulation of Tensile Behavior of Corroded Aluminum Alloy 2024 T3 Considering the Hydrogen Embrittlement
Jan 2018
Publication
A multi-scale modeling approach for simulating the tensile behavior of the corroded aluminum alloy 2024 T3 was developed accounting for both the geometrical features of corrosion damage and the effect of corrosion-induced hydrogen embrittlement (HE). The approach combines two Finite Element (FE) models: a model of a three-dimensional Representative Unit Cell (RUC) representing an exfoliated area and its correspondent hydrogen embrittled zone (HEZ) and a model of the tensile specimen. The models lie at the micro- and macro-scales respectively. The characteristics of the HEZ are determined from measurements of nanoindentation hardness conducted on pre-corroded specimens. Using the model of the RUC the local homogenized mechanical behavior of the corroded material is simulated. Then the behavior of the exfoliated areas is assigned into different areas (elements) of the tensile specimen and final analyses are performed to simulate the tensile behavior of the corroded material. The approach was applied to model specimens after 8 16 and 24 h exposure periods of the Exfoliation Corrosion (EXCO) test. For validation of the approach tensile tests were used. The numerical results show that this approach is suitable for accurately simulating the tensile behavior of pre-corroded experimental specimens accounting for both geometrical features of corrosion damage and corrosion-induced HE.
Exergetic Aspects of Hydrogen Energy Systems—The Case Study of a Fuel Cell Bus
Feb 2017
Publication
Electrifying transportation is a promising approach to alleviate climate change issues arising from increased emissions. This study examines a system for the production of hydrogen using renewable energy sources as well as its use in buses. The electricity requirements for the production of hydrogen through the electrolysis of water are covered by renewable energy sources. Fuel cells are being used to utilize hydrogen to power the bus. Exergy analysis for the system is carried out. Based on a steady-state model of the processes exergy efficiencies are calculated for all subsystems. The subsystems with the highest proportion of irreversibility are identified and compared. It is shown that PV panel has exergetic efficiency of 12.74% wind turbine of 45% electrolysis of 67% and fuel cells of 40%.
Editorial—Special Issue “Catalysis for Energy Production”
Jun 2021
Publication
The rapid increase in anthropogenic greenhouse gas concentrations in the last several decades means that the effects of climate change are fast becoming the familiar horsemen of a planetary apocalypse. Catalysis one of the pillars of the chemical and petrochemical industries will play a critical role in the effort to reduce the flow of greenhouse gases into the atmosphere. This Special Issue is timely as it provides a collection of high-quality manuscripts in a diverse range of topics which include the production of green hydrogen via water electrolysis the steam reforming of ethanol propane or glycerol the dry reforming of methane and the autothermal reforming of diesel surrogate fuel. The topic of the transformation of biomass waste to chemicals is also well represented as is the tackling of CO2 emissions via novel utilization technologies. The Editors are grateful to all authors for their valuable contributions and confident that this Special Issue will prove valuable to scholars university professors and students alike.
No more items...