Safety
Large-Scale Hydrogen Deflagrations and Detonations
Sep 2005
Publication
Large-scale deflagration and detonation experiments of hydrogen and air mixtures provide fundamental data needed to address accident scenarios and to help in the evaluation and validation of numerical models. Several different experiments of this type were performed. Measurements included flame front time of arrival (TOA) using ionization probes blast pressure heat flux high-speed video standard video and infrared video. The large-scale open-space tests used a hemispherical 300-m3 facility that confined the mixture within a thin plastic tent that was cut prior to initiating a deflagration. Initial homogeneous hydrogen concentrations varied from 15% to 30%. An array of large cylindrical obstacles was placed within the mixture for some experiments to explore turbulent enhancement of the combustion. All tests were ignited at the bottom center of the facility using either a spark or in one case a small quantity of high explosive to generate a detonation. Spark-initiated deflagration tests were performed within the tunnel using homogeneous hydrogen mixtures. Several experiments were performed in which 0.1 kg and 2.2 kg of hydrogen were released into the tunnel with and without ventilation. For some tunnel tests obstacles representing vehicles were used to investigate turbulent enhancement. A test was performed to investigate any enhancement of the deflagration due to partial confinement produced by a narrow gap between aluminium plates. The attenuation of a blast wave was investigated using a 4-m-tall protective blast wall. Finally a large-scale hydrogen jet experiment was performed in which 27 kg of hydrogen was released vertically into the open atmosphere in a period of about 30 seconds. The hydrogen plume spontaneously ignited early in the release.
Spontaneous Ignition of Hydrogen Leaks, a Review of Postulated Mechanisms
Sep 2005
Publication
Over the last century there have been reports of high pressure hydrogen leaks igniting for no apparent reason and several ignition mechanisms have been proposed. Although many leaks have ignited there are also reported leaks where no ignition has occurred. Investigations of ignitions where no apparent ignition source was present have often been superficial with a mechanism postulated which whilst appearing to satisfy the conditions prevailing at the time of the release simply does not stand up to rigorous scientific analysis. Some of these proposed mechanisms have been simulated in a laboratory under superficially identical conditions and appear to be rigorous and scientific but the simulated conditions often do not have the same large release rates or quantities mainly because of physical constraints of a laboratory. Also some of the release scenarios carried out or simulated in laboratories are totally divorced from the realistic situation of most actual leaks. Clearly there are gaps in the knowledge of the exact ignition mechanism for releases of hydrogen particularly at the high pressures likely to be involved in future storage and use. Mechanisms which have been proposed in the past are the reverse Joule-Thomson effect; electrostatic charge generation; diffusion ignition; sudden adiabatic compression; and hot surface ignition. Of these some have been characterized by means of computer simulation rather than by actual experiment and hence are not validated. Consequently there are discrepancies between the theories releases known to have ignited and releases which are known to have not ignited. From this postulated ignition mechanisms which are worthy of further study have been identified and the gaps in information have been highlighted. As a result the direction for future research into the potential for ignition of hydrogen escapes has been identified.
Large Scale Experiments- Deflagration and Deflagration to Detonation within a Partial Confinement Similar to a Lane
Sep 2005
Publication
About 20 years ago Fraunhofer ICT has performed large scale experiments with premixed hydrogen air mixtures [1]. A special feature has been the investigation of the combustion of the mixture within a partial confinement simulating some sort of a “lane” which may exist in reality within a hydrogen production or storage plant for example. Essentially three different types of tests have been performed: combustion of quiescent mixtures combustion of mixtures with artificially generated turbulence by means of a fan and combustion of mixtures with high speed flame jet ignition. The observed phenomena will be discussed on the basis of measured turbulence levels flame speeds and overpressures. Conditions for DDT concerning critical turbulence levels and flame speeds as well as a scaling rule for DDT related to the detonation cell size of the mixture can be derived from the experiments for this special test setup. The relevance of the results with respect to safety aspects of future hydrogen technology is assessed. Combustion phenomena will be highlighted by the presentation of impressive high speed film videos.
Dynamic Crush Test on Hydrogen Pressurized Cylinder
Sep 2005
Publication
It is necessary to investigate cylinder crush behavior for improvement of fuel cell vehicle crash safety. However there have been few crushing behaviour investigations of high pressurized cylinders subjected to external force. We conducted a compression test of pressurized cylinders impacted by external force. We also investigated the cylinder strength and crushing behaviour of the cylinder. The following results were obtained.
- The crush force of high pressurized cylinders is different from the direction of external force. The lateral crush force of high pressurized cylinders is larger than the external axial crush force.
- Tensile stress occurs in the boundary area between the cylinder dome and central portion when the pressurized cylinder is subjected to axial compression force and the cylinder is destroyed.
- However the high pressurized cylinders tested had a high crush force which exceeded the assumed range of vehicle crash test procedures
Requirements for the Safety Assessment for the Approval of a Hydrogen Refueling Station
Sep 2007
Publication
The EC 6th framework research project HyApproval will draft a Handbook which will describe all relevant issues to get approval to construct and operate a Hydrogen Refuelling Station (HRS) for hydrogen vehicles. In WP3 of the HyApproval project it is under investigation which safety information competent authorities require to give a licence to construct an operate an HRS. The paper describes the applied methodology to collect the information from the authorities in 5 EC countries and the USA. The results of the interviews and recommendations for the information to include in the Handbook are presented.
Development of High-pressure Hydrogen Gas Barrier Materials
Oct 2015
Publication
We prepared several gas barrier resins based on amorphous PVA derivative that has the T1C (13C spin-lattice relaxation time) of a long time component in amorphous phase. We confirmed it was important to control state in amorphous phase of gas barrier resin in order to achieve both moldability and good gas barrier property. Polymer alloy was designed to improve flexibility. Polymer alloy made of amorphous PVA and elastomer resin showed good hydrogen resistance. Even after its polymer alloy were repeatedly exposed to 70MPa hydrogen gas the influence on higher-order structure in amorphous phase was in negligible level.
Hydrogen Onboard Storage: An Insertion of the Probabilistic Approach Into Standards & Regulations?
Sep 2005
Publication
The growing attention being paid by car manufacturers and the general public to hydrogen as a middle and long term energy carrier for automotive purpose is giving rise to lively discussions on the advantages and disadvantages of this technology – also with respect to safety. In this connection the focus is increasingly and justifiably so on the possibilities offered by a probabilistic approach to loads and component characteristics: a lower weight obliged with a higher safety level basics for an open minded risk communication the possibility of a provident risk management the conservation of resources and a better and not misleading understanding of deterministic results. But in the case of adequate measures of standards or regulations completion there is a high potential of additional degrees of freedom for the designers obliged with a further increasing safety level. For this purpose what follows deals briefly with the terminological basis and the aspects of acceptance control conservation of resources misinterpretation of deterministic results and the application of regulations/standards.<br/>This leads into the initial steps of standards improvement which can be taken with relatively simple means in the direction of comprehensively risk-oriented protection goal specifications. By this it’s not focused on to provide to much technical details. It’s focused on the context of different views on probabilistic risk assessment. As main result some aspects of the motivation and necessity for the currently running pre-normative research studies within the 6th frame-work program of the EU will be shown.
H2 High Pressure On-board Storage Considering Safety Issues
Sep 2007
Publication
The present paper reviews the state-of-the-art of integrated structural integrity monitoring systems applicable to hydrogen on-board applications. Storage safety and costs are key issues for the success of the hydrogen technology considered for replacing the conventional fuel systems in transport applications. An in-service health monitoring procedure for high pressure vessels would contribute to minimize the risks associated to high pressure hydrogen storage and to improve the public acceptance. Such monitoring system would also enable a reduction on design burst criteria enabling savings in material costs and weight. This paper reviews safety and maintenance requirements based on present standards for high pressure vessels. A state-of-the-art of storage media and materials for onboard storage tank is presented as well as of current European programmes on hydrogen storage technologies for transport applications including design safety and system reliability. A technological road map is proposed for the development and validation of a prototype within the framework of the Portuguese EDEN project. To ensure safety an exhaustive test procedure is proposed. Furthermore requirements of a safety on-board monitoring system is defined for filament wound hydrogen tanks.
Evaluation of Safety Distances Related to Unconfined Hydrogen Explosions
Sep 2005
Publication
A simple approximate method for evaluation of blast effects and safety distances for unconfined hydrogen explosions is presented. The method includes models for flame speeds hydrogen distribution blast parameters and blast damage criteria. An example of the application of this methodology for hydrogen releases in three hypothetical obstructed areas with different levels of congestion is presented. The severity of the blast effect of unconfined hydrogen explosions is shown to depend strongly on the level of congestion for relatively small releases. Extremely large releases of hydrogen are predicted to be less sensitive to the congestion level.
Hydrogen Flames in Tubes- Critical Run-up Distances
Sep 2007
Publication
The hazard associated with flame acceleration to supersonic speeds in hydrogen mixtures is discussed. A set of approximate models for evaluation of the run-up distances to supersonic flames in relatively smooth tubes and tubes with obstacles is presented. The model for smooth tubes is based on general relationships between the flame area turbulent burning velocity and the flame speed combined with an approximate description for the boundary layer thickness ahead of an accelerated flame. The unknown constants of the model are evaluated using experimental data. This model is then supplemented with the model for the minimum run-up distance for FA in tubes with obstacles developed earlier. On the basis of these two models solutions for the determination of the critical runup distances for FA and deflagration to detonation transition in tubes and channels for various hydrogen mixtures initial temperature and pressure tube size and tube roughness are presented.
Dispersion Tests on Concentration and its Fluctuations for 40MPa Pressurized Hydrogen
Sep 2007
Publication
Hydrogen is one of the important alternative fuels for future transportation. At the present stage research into hydrogen safety and designing risk mitigation measures are significant task. For compact storage of hydrogen in fuel cell vehicles storage of hydrogen under high pressure up to 40 MPa at refuelling stations is planned and safety in handling such high-pressure hydrogen is essential. This paper describes our experimental investigation into dispersion of high-pressure hydrogen gas which leaks through pinholes in the piping to the atmosphere. First in order to comprehend the basic behaviour of the steady dispersion of high-pressure hydrogen gas from the pinholes the time-averaged concentrations were measured. In our experiments initial release pressures of hydrogen gas were set at 20 MPa or 40 MPa and release diameters were in the range from 0.25 mm to 2 mm. The experimental results show that the hydrogen concentration along the axis of the dispersion plume can be expressed as a simple formula which is a function of the downwind distance X and the equivalent release diameter. This formula enables us to easily estimate the axial concentration (maximum concentration) at each downstream distance. However in order for the safety of flammable gas dispersion to be analyzed comparisons between time-averaged concentrations evaluated as above and lower flammable limit are insufficient. This is because even if time-averaged concentration is lower than the flammability limit instantaneous concentrations fluctuate and a higher instantaneous concentration occasionally appears due to turbulence. Therefore the time-averaged concentration value which can be used as a threshold for assessing safety must be determined considering concentration fluctuations. Once the threshold value is determined the safe distance from the leakage point can be evaluated by the above-mentioned simple formula. To clarify the phenomenon of concentration fluctuations instantaneous concentrations were measured with the fast-response flame ionization detector. A small amount of methane gas was mixed into the hydrogen as a tracer gas for this measurement. The relationship between the time-mean concentration and the occurrence probability of flammable concentration was analyzed. Under the same conditions spark-ignition experiments were also conducted and the relationship between the occurrence probability of flammable concentration and actual ignition probabilities were also investigated. The experimental results show that there is a clear correlation between the time-mean concentration the occurrence probability of flammable concentration flame length and occurrence probability of hydrogen flame.
Physics of Spontaneous Ignition of High-Pressure Hydrogen Release and Transition to Jet Fire
Sep 2009
Publication
The main objective of this study is an insight into physical phenomena underlying spontaneous ignition of hydrogen at sudden release from high pressure storage and its transition into the sustained jet fire. This paper describes modelling and large eddy simulation (LES) of spontaneous ignition dynamics in a tube with a rupture disk separating high pressure hydrogen storage and the atmosphere. Numerical experiments carried out by a LES model have provided an insight into the physics of the spontaneous ignition phenomenon. It is demonstrated that a chemical reaction commences in a boundary layer within the tube and propagates throughout the tube cross-section after that. Simulated by the LES model dynamics of flame formation outside the tube has reproduced experimental observation of combustion by high-speed photography including vortex induced “flame separation". It is concluded that the model developed can be applied for hydrogen safety engineering in particular for development of innovative pressure relief devices.
Risk Analysis of the Storage Unit in Hydrogen Refuelling Station
Sep 2007
Publication
Nowadays consumer demand for local and global environmental quality in terms of air pollution and in particular greenhouse gas emissions reduction may help to drive to the introduction of zero emission vehicles. At this regard the hydrogen technology appears to have future market valuablepotential. On the other hand the use of hydrogen vehicles which requires appropriate infrastructures for production storage and refuelling stages presents a lot of safety problems due to the peculiar chemicophysical hydrogen characteristics. Therefore safe at the most practices are essential for the successful proliferation of hydrogen vehicles. Indeed to avoid limit hazards it is necessary to implement practices that if early adopted in the development of a fuelling station project can allow very low environmental impact safety being incorporated in the project itself. Such practices generally consist in the integrated use of Failure Mode and Effect Analysis (FMEA) HAZard OPerability (HAZOP) and Fault Tree Analysis (FTA) which constitute well established standards in reliability engineering. At this regard however a drawback is the lack of experience and the scarcity of the relevant data collection. In this work we present the results obtained by the integrated use of FMEA HAZOP and FTA analyses relevant for the moment the high-pressure storage equipment in a hydrogen gas refuelling station. The study that is intended to obtain elements for improving safety of the system can constitute a basis for further more refined works.
The Structure and Flame Propagation Regimes in Turbulent Hydrogen Jets
Sep 2009
Publication
Experiments on flame propagation regimes in a turbulent hydrogen jet with velocity and hydrogen concentration gradients have been performed at the FZK hydrogen test site HYKA. Horizontal stationary hydrogen jets released at normal and cryogenic temperatures of 290K and 80 and 35K with different nozzle diameters and mass flow rates in the range from 0.3 to 6.5 g/s have been investigated. Sampling probe method and laser PIV technique have been used to evaluate distribution of hydrogen concentration and flow velocity along and across the jet axis. High-speed photography (1000 fps) combined with a Background Oriented Schlieren (BOS) system was used for the visual observation of the turbulent flame propagation. In order to investigate different flame propagation regimes the ignition position was changed along the jet axis. It was found that the maximum flame velocity and pressure loads can only occur if the hydrogen concentration at the ignition point exceeds 11% of hydrogen in air. In this case the flame propagates in both directions up- and downstream the jet flow whereas in the opposite case the flame propagates only downstream. Such a behavior is consistent with previous experiments according to that the flame is able to accelerate effectively only if the expansion rate σ of the H2-air mixture is higher than a critical value σ* = 3.75 (like for the 11% hydrogen-air mixture). The measured data allow conservative estimates of the safety distance and risk assessment for realistic hydrogen leaks.
Complex Hydrides as Solid Storage Materials- First Safety Tests
Sep 2007
Publication
Hydrogen technology requires efficient and safe hydrogen storage systems. For this purpose storage in solid materials such as high capacity complex hydrides is studied intensely. Independent from the actual material to be used eventually any tank design will combine nanoscale powders of highly reactive material with pressurized hydrogen gas and so far little is known about the behaviour of these mixtures in case of incidents. For a first evaluation of a complex hydride in case of a tank failure NaAlH4 (doped with Ti) was investigated in a small scale tank failure tests. 80-100 ml of the material were filled into a heat exchanger tube and sealed under argon atmosphere with a burst disk. Subsequently the NaAlH4 was partially desorbed by heating. When the powder temperature reached 130 °C and the burst disk ruptured at 9 bar hydrogen overpressure the behaviour of the expelled powder was monitored using a high speed camera an IR camera as well as sound level meters. Expulsion of the hydrogen storage material into (dry) ambient atmosphere yields a dust cloud of finely dispersed powder which does not ignite spontaneously. Similar experiments including an external source of ignition (spark / water reacting with NaAlH4) yield a flame of reacting powder. The intensity will be compared to the reaction of an equivalent amount of pure hydrogen.
Polymer Composites for Tribological Applications in Hydrogen Environment
Sep 2007
Publication
In the development of hydrogen technology special attention is paid to the technical problems of hydrogen storage. One possible way is cryogenic storage in liquid form. Generally cryo-technical machines need components with interacting surfaces in relative motion such as bearings seals or valves which are subjected to extreme conditions. Materials of such systems have to be resistant to friction-caused mechanical deformation at the surface low temperatures and hydrogen environment. Since materials failure can cause uncontrolled escape of hydrogen new material requirements are involved for these tribo-systems in particular regarding operability and reliability. In the past few years several projects dealing with the influence of hydrogen on the tribological properties of friction couples were conducted at the Federal Institute for Materials Research and Testing (BAM) Berlin. This paper reports some investigations carried out with polymer composites. Friction and wear were measured for continuous sliding and analyses of the worn surfaces were performed after the experiments. Tests were performed at room temperature in hydrogen as well as in liquid hydrogen.
An Intercomparison Exercise on the Capabilities of CFD Models to Predict Deflagration of a Large-Scale H2-Air Mixture in Open Atmosphere
Sep 2005
Publication
This paper presents a compilation of the results supplied by HySafe partners participating in the Standard Benchmark Exercise Problem (SBEP) V2 which is based on an experiment on hydrogen combustion that is first described. A list of the results requested from participants is also included. The main characteristics of the models used for the calculations are compared in a very succinct way by using tables. The comparison between results together with the experimental data when available is made through a series of graphs. The results show quite good agreement with the experimental data. The calculations have demonstrated to be sensitive to computational domain size and far field boundary condition.
Thermal Loading Cases of Hydrogen High Pressure Storage Cylinders
Sep 2007
Publication
Composite cylinders with metal liner are used for the storage of compressed hydrogen in automotive application. These hybrid pressure cylinders are designed for a nominal working pressure of up to 70 MPa. They also have to withstand a temperature range between -40°C and +85°C according GRPE draft [1] and for short periods up to a maximum temperature of 140°C during filling (fast filling) [2]. In order to exploit the material properties efficiently with a high degree of lightweight optimization and a high level of safety on the same time a better understanding of the structural behavior of hybrid designs is necessary. Work on this topic has been carried out in the frame of a work package on safety aspects and regulation (Subproject SAR) of the European IP StorHy (www.storhy.net). The temperature influence on the composite layers is distinctive due to there typical polymer material behavior. The stiffness of the composite layer is a function of temperature which influences global strains and stress levels (residual stresses) in operation. In order to do an accurate fatigue assessment of composite hybrid cylinders a realistic modeling of a representative temperature load is needed. For this climate data has been evaluated which were collected in Europe over a period of 30 years [3]. Assuming that the temperature follows a Gaussian (normal) distribution within the assessed period of 30 years it is possible to generate a frequency distribution for different temperature classes for the cold extreme and the hot extreme. Combining these distributions leads to the overall temperature range distribution (frequency over temperature classes). The climatic temperature influence the filling temperature and the pressure load have to be considered in combination with the operation profile of the storage cylinder to derive a complete load vector for an accurate assessment of the lifetime and safety level.
Optimization of a Solar Hydrogen Storage System: Safety Considerations
Sep 2007
Publication
Hydrogen has been extensively used in many industrial applications for more than 100 years including production storage transport delivery and final use. Nevertheless the goal of the hydrogen energy system implies the use of hydrogen as an energy carrier in a more wide scale and for a public not familiarised with hydrogen technologies and properties.<br/>The road to the hydrogen economy passes by the development of safe practices in the production storage distribution and use of hydrogen. These issues are essential for hydrogen insurability. We have to bear in mind that a catastrophic failure in any hydrogen project could damage the insurance public perception of hydrogen technologies at this early step of development of hydrogen infrastructures.<br/>Safety is a key issue for the development of hydrogen economy and a great international effort is being done by different stakeholders for the development of suitable codes and standards concerning safety for hydrogen technologies [1 2]. Additionally to codes and standards different studies have been done regarding safety aspects of particular hydrogen energy projects during the last years [3 4]. Most of such have been focused on hydrogen production and storage in large facilities transport delivery in hydrogen refuelling stations and utilization mainly on fuel cells for mobile and stationary applications. In comparison safety considerations for hydrogen storage in small or medium scale facilities as usual in hydrogen production plants from renewable energies have received relatively less attention.<br/>After a brief introduction to risk assessment for hydrogen facilities this paper reports an example of risk assessment of a small solar hydrogen storage system applied to the INTA Solar Hydrogen Production and Storage facility as particular case and considers a top level Preliminary Failure Modes and Effects Analysis (FMEA) for the identification of hazard associated to the specific characteristics of the facility.
A Rural Hydrogen Transportation Test Bed
Sep 2007
Publication
The University of Missouri-Rolla (UMR) through a hydrogen internal combustion engine vehicle evaluation participation agreement with the Ford Motor Company will establish a commuter bus service and hydrogen refueling at a station in rural Missouri near Ft. Leonard Wood (FLW). Initiated by a request from the U.S. Army Maneuver Support Center at FLW UMR is leading the effort to launch the commuter service between FLW and the neighboring towns of Rolla and Lebanon Missouri each of which are located approximately 40 km from the military base on Interstate-44 highway. The broad research training and education agenda for the rural hydrogen transportation test bed is to develop demonstrate evaluate and promote safe hydrogen-based technologies in a real world environment. With funds provided by the Defense Logistics Agency through the Air Force Research Laboratory this hydrogen initiative will build and operate a hydrogen fueling facility that includes on-site generation of hydrogen through electrolysis as well as selling a range of other traditional and alternative fuels.
Hydrogen Releases Ignited in a Simulated Vehicle Refuelling Environment
Sep 2007
Publication
If the general public is to use hydrogen as a vehicle fuel customers must be able to handle hydrogen with the same degree of confidence and with comparable risk as conventional liquid and gaseous fuels. The hazards associated with jet releases from leaks in a vehicle-refuelling environment must be considered if hydrogen is stored and used as a high-pressure gas since a jet release in a confined or congested area could result in an explosion. As there was insufficient knowledge of the explosion hazards a study was initiated to gain a better understanding of the potential explosion hazard consequences associated with high-pressure leaks from refuelling systems. This paper describes two experiments with a dummy vehicle and dispenser units to represent refuelling station congestion. The first represents a ‘worst-case’ scenario where the vehicle and dispensers are enveloped by a 5.4 m x 6.0 m x 2.5 m high pre-mixed hydrogen-air cloud. The second is an actual high-pressure leak from storage at 40 MPa (400 bar) representing an uncontrolled full-bore failure of a vehicle refuelling hose. In both cases an electric spark ignited the flammable cloud. Measurements were made of the explosion overpressure generated its evolution with time and its decay with distance. The results reported provide a direct demonstration of the explosion hazard from an uncontrolled leak; they will also be valuable for validating explosion models that will be needed to assess configurations and conditions beyond those studied experimentally.
Validation of CFD Calculations Against Ignited Impinging Jet Experiments
Sep 2007
Publication
Computational Fluid Dynamics (CFD) tools have been increasingly employed for carrying out quantitative risk assessment (QRA) calculations in the process industry. However these tools must be validated against representative experimental data in order to have a real predictive capability. As any typical accident scenario is quite complex it is important that the CFD tool is able to predict combined release and ignition scenarios reasonably well. However this kind of validation is not performed frequently primarily due to absence of good quality data. For that reason the recent experiments performed by FZK under the HySafe internal project InsHyde (http://www.hysafe.org) are important. These involved vertically upwards hydrogen releases with different release rates and velocities impinging on a plate in two different geometrical configurations. The dispersed cloud was subsequently ignited and pressures recorded. These experiments are important not only for corroborating the underlying physics of any large-scale safety study but also for validating the important assumptions used in QRA. Blind CFD simulations of the release and ignition scenarios were carried out prior to the experiments to predict the results (and possibly assist in planning) of the experiments. The simulated dispersion results are found to correlate reasonably well with experimental data in terms of the gas concentrations. The overpressures subsequent to ignition obtained in the blind predictions could not be compared directly with the experiments as the ignition points were somewhat different but the pressure levels were found to be similar. Simulations carried out after the experiments with the same ignition position as those in the experiments compared reasonably well with the measurements in terms of the pressure level. This agreement points to the ability of the CFD tool FLACS to model such complex scenarios well. Nevertheless the experimental set-up can be considered to be small-scale and less severe than many accidents and real-life situations. Future large-scale data of this type will be valuable to confirm ability to predict large-scale accident scenarios.
Characterization of Materials in Pressurized Hydrogen Under Cyclic Loading at Service Conditions in Hydrogen Powered Engines
Sep 2005
Publication
A new testing device for cyclic loading of specimens with a novel shape design is presented. The device was applied for investigations of fatigue of metallic specimens under pressurized hydrogen up to 300 bar at temperatures up to 200 °C. Main advantage of the specimen design is the very small amount of medium here hydrogen used for testing. This allows experiments with hazardous substances at lower safety level. Additionally no gasket for the load transmission is required. Woehler curves which show the influence of hydrogen on the fatigue behaviour of austenitic steel specimens at relevant service conditions in hydrogen powered engines are presented. Material and test conditions are in agreement with the cooperating industry.
Fast Turbulent Deflagration and DDT of Hydrogen-Air Mixtures in Small Obstructed Channel
Sep 2007
Publication
An experimental study of flame propagation acceleration and transition to detonation in hydrogen-air mixture in 2 m long rectangular cross section channel filled with obstacles located at the bottom wall was performed. The initial conditions of the hydrogen-air mixture were 0.1 MPa and 293 K. Three different cases of obstacle height (blockage ratio 0.25 0.5 and 0.75) and four cases of obstacle density were studied with the channel height equal to 0.08 m. The channel width was 0.11 m in all experiments. The propagation of flame and pressure waves was monitored by four pressure transducers and four in house ion probes. The pairs of transducers and probes were placed at various locations along the channel in order to get information about the progress of the phenomena along the channel. To examine the influence of mixture composition on flame propagation and DDT the experiments were performed for the compositions of 20% 25% and 29.6% of H2 in air by volume. As a result of the experiments the deflagration and detonation regimes and velocities of flame propagation in the obstructed channel were determined.
Identification and Monitoring of a PEM Electrolyser Based on Dynamical Modelling
Sep 2007
Publication
Hydrogen from water electrolysis associated with renewable energies is one of the most attractive solutions for the green energy storage. To improve the efficiency and the safety of such stations some technological studies are still under investigation both on methods and materials. As methods control monitoring and diagnosis algorithms are relevant tools. These methods are efficient when they use an accurate mathematical model representing the real behaviour of hydrogen production system. This work focuses on the dynamical modelling and the monitoring of Proton Exchange Membrane (PEM) electrolyser. Our contribution consists in three parts: to develop an analytical dynamical PEM electrolyser model dedicated to the control and the monitoring; to identify the model parameters and to propose adequate monitoring tools. The proposed model is deduced from physical laws and electrochemical equations and consists in a steady-state electric model coupled with a dynamical thermal model. The estimation of the model parameters is achieved using identification and data fitting techniques based on experimental measurements. Taking into account the information given by the proposed analytical model and the experimentation data (temperature T voltage U and current I) given by a PEM electrolyser composed of seven cells the model parameters are identified. After estimating the dynamical model model based diagnosis approach is used in order to monitoring the PEM electrolyser and to ensure its safety. We illustrate how our algorithm can detect and isolate faults on actuators on sensors or on electrolyser system.<br/><br/>
Methodology of CFD Safety Analysis for Large-Scale Industrial Structures
Sep 2005
Publication
The current work is devoted to problems connected with application of CFD tools for safety analysis of large-scale industrial structures. With the aim to preserve conservatism of overall process of multistage procedure of such analysis special efforts are required. A strategy which has to lead to obtaining of reliable results in CFD analysis is discussed. Different aspects of proposed strategy including: adequate choice of physical and numerical models procedure of validation simulations and problem of ‘under-resolved’ simulations are considered. For physical phenomena which could cause significant uncertainties in the course of scenario simulation an approach which complements CFD simulations by application of auxiliary criteria is presented. Physical basis and applicability of strong flame acceleration and detonation-to-deflagration transition criteria are discussed. In concluding part two examples of application of presented approach for nuclear power plant and workshop cell for hydrogen driven vehicles are presented.
Hydrogen Safety- From Policies to Plans to Practices
Sep 2005
Publication
Safety is an essential element for realizing the “hydrogen economy” – safe operation in all of its aspects from hydrogen production through storage distribution and use; from research development and demonstration to commercialization. As such safety is given paramount importance in all facets of the research development and demonstration of the U.S Department of Energy’s (DOE) Hydrogen Fuel Cells and Infrastructure Technologies (HFCIT) Program Office. The diversity of the DOE project portfolio is self-evident. Projects are performed by large companies small businesses DOE National Laboratories academic institutions and numerous partnerships involving the same. Projects range from research exploring advances in novel hydrogen storage materials to demonstrations of hydrogen refuelling stations and vehicles. Recognizing the nature of its program and the importance of safety planning DOE has undertaken a number of initiatives to encourage and shape safety awareness. The DOE Hydrogen Safety Review Panel was formed to bring a broad cross-section of expertise from the industrial government and academic sectors to help ensure the success of the program as a whole. The Panel provides guidance on safety-related issues and needs reviews individual DOE-supported projects and their safety plans and explores ways to bring learnings to broadly benefit the DOE program. This paper explores the approaches used for providing safety planning guidance to contractors in the context of their own (and varied) policies procedures and practices. The essential elements that should be included in safety plans are described as well as the process for reviewing project safety plans. Discussion of safety planning during the conduct of safety review site visits is also shared. Safety planning-related learnings gathered from project safety reviews and the Panel’s experience in reviewing safety plans are discussed.
Numerical Simulation of Hydrogen Explosion Tests with a Barrier Wall for Blast Mitigation
Sep 2005
Publication
We have investigated hydrogen explosion risk and its mitigation focusing on compact hydrogen refuelling stations in urban areas. In this study numerical analyses were performed of hydrogen blast propagation and the structural behaviour of barrier walls. Parametric numerical simulations of explosions were carried out to discover effective shapes for blast-mitigating barrier walls. The explosive source was a prismatic 5.27 m3 volume that contained 30% hydrogen and 70% air. A reinforced concrete wall 2 m tall by 10 m wide and 0.15 m thick was set 2 or 4 m away from the front surface of the source. The source was ignited at the bottom centre by a spark for the deflagration case and 10 g of C-4 high explosive for two detonation cases. Each of the tests measured overpressures on the surfaces of the wall and on the ground displacements of the wall and strains of the rebar inside the wall. The blast simulations were carried out with an in-house CFD code based on the compressive Euler equation. The initial energy estimated from the volume of hydrogen was a time-dependent function for the deflagration and was released instantaneously for the detonations. The simulated overpressures were in good agreement with test results for all three test cases. DIANA a finite element analysis code released by TNO was used for the structural simulations of the barrier wall. The overpressures obtained by the blast simulations were used as external forces. The analyses simulated the displacements well but not the rebar strains. The many shrinkage cracks that were observed on the walls some of which penetrated the wall could make it difficult to simulate the local behaviour of a wall with high accuracy and could cause strain gages to provide low-accuracy data. A parametric study of the blast simulation was conducted with several cross-sectional shapes of barrier wall. A T-shape and a Y-shape were found to be more effective in mitigating the blast.
Canadian Hydrogen Safety Program.
Sep 2005
Publication
This paper discusses the rationale structure and contents of the Canadian Hydrogen Safety Program developed by the Codes & Standards Working Group of the Canadian Transportation Fuel Cell Alliance consisting of representatives from industry academia government and regulators. The overall program objective is to facilitate acceptance of the products services and systems of the Canadian Hydrogen Industry by the Canadian Hydrogen Stakeholder Community to facilitate trade ensure fair insurance policies and rates ensure effective and efficient regulatory approval procedures and to ensure that the interests of the general public are accommodated. The Program consists of four projects including Comparative Quantitative Risk Assessment of Hydrogen and Compressed Natural Gas (CNG) Refuelling Stations; Computational Fluid Dynamics (CFD) Modelling Validation Calibration and Enhancement; Enhancement of Frequency and Probability Analysis and Consequence Analysis of Key Component Failures of Hydrogen Systems; and Fuel Cell Oxidant Outlet Hydrogen Sensor Project. The Program projects are tightly linked with the content of the IEA Task 19 Hydrogen Safety. The Program also includes extensive (destructive and non-destructive) testing of hydrogen components.
Sensitivity to Detonation and Detonation Cellular Structure of H2-O2-AIr-H2O2 Gas Mixtures
Sep 2005
Publication
Today it is not known – neither qualitatively not quantitatively - how large the impact can be of the promoters on sensitivity to hydrogen-air detonation in hypothetical accidents at hydrogen-containing installations transport or storage facilities. Report goal is to estimate theoretically an effect of hydrogen-peroxide (as representative promoter) on sensitivity to detonation of the stoichiometric hydrogen-oxygen gas mixtures. The classical H2-O2-Ar (2:1:7) gas mixture was chosen as reference system with the well established and unambiguously interpreted experimental data. In kinetic simulations it was found that the ignition delay time is sensitive to H2O2addition for small initial H2O2concentrations and is nearly constant for the large ones. Parametric reactive CFD studies of two dimensional cellular structure of 2H2-O2-7Ar-H2O2 detonations with variable hydrogen peroxide concentration (up to 10 vol.%) were also performed. Two un-expected results were obtained. First result: detonation cell size is practically independent upon variation of initial hydrogen peroxide concentration. For practical applications it means that presence of hydrogen-peroxide did not change drastically sensitivity of the stoichiometric hydrogen-oxygen gas mixtures. These theoretical speculations require an experimental verification. Second result: for large enough initial H2O2concentrations (> 1 vol.% at least) a new element of cellular structure of steady detonation wave was revealed. It is a system of multiple secondary longitudinal shock waves (SLSW) which propagates in the direction opposite to that of the leading shock wave. Detailed mechanism of SLSW formation is proposed.
An Intercomparison Exercise on the Capabilities of CFD Models to Predict Distribution and Mixing of H2 in a Closed Vessel.
Sep 2005
Publication
This paper presents a compilation and discussion of the results supplied by HySafe partners participating in the Standard Benchmark Exercise Problem (SBEP) V1 which is based on an experiment on hydrogen release mixing and distribution inside a vessel. Each partner has his own point of view of the problem and uses a different approach to the solution. The main characteristics of the models employed for the calculations are compared. The comparison between results together with the experimental data when available is made. Relative deviations of each model from the experimental values are also included. Explanations and interpretations of the results are presented together with some useful conclusions for future work.
Numerical Study of a Highly Under-Expanded Hydrogen Jet
Sep 2005
Publication
Numerical simulations are carried out for a highly under-expanded hydrogen jet resulting from an accidental release of high-pressure hydrogen into the atmospheric environment. The predictions are made using two independent CFD codes namely CFX and KIVA. The KIVA code has been substantially modified by the present authors to enable large eddy simulation (LES). It employs a oneequation sub-grid scale (SGS) turbulence model which solves the SGS kinetic energy equation to allow for more relaxed equilibrium requirement and to facilitate high fidelity LES calculations with relatively coarser grids. Instead of using the widely accepted pseudo-source approach the complex shock structures resulting from the high under-expansion is numerically resolved in a small computational domain above the jet exit. The computed results are used as initial conditions for the subsequent hydrogen jet simulation. The predictions provide insight into the shock structure and the subsequent jet development. Such knowledge is valuable for studying the ignition characteristics of high-pressure hydrogen jets in the safety context.
CFD Simulation on Diffusion of Leaked Hydrogen Caused by Vehicle Accident in Tunnels
Sep 2005
Publication
Hydrogen fuel cell vehicles are expected to come into widespread use in the near future. Accordingly many hydrogen carrying vehicles will begin to pass through tunnels. It is therefore important to predict whether risk from leaked hydrogen accidents in tunnels can be avoided. CFD simulation was carried out on diffusion of leaked hydrogen in tunnels. Three areas of tunnels were chosen for study. One is the typical longitudinal and lateral areas of tunnels and the others are underground ventilation facilities and electrostatic dust collectors which were simulated with an actual tunnel. The amount of hydrogen leaked was 60m3 (approximately 5.08 kg) which corresponds to the amount necessary for future fuel cell vehicles to achieve their desired running distance. Analytical periods were the time after leaks began until regions of hydrogen above the low flammability limit had almost disappeared or thirty minutes. We found that leaked hydrogen is immediately carried away from leaking area under existing ventilation conditions. We also obtained basic data on behaviour of leaked hydrogen.
Experimental Study on Hydrogen Explosions in a Full-scale Hydrogen Filling Station Model
Sep 2005
Publication
In order for fuel cell vehicles to develop a widespread role in society it is essential that hydrogen refuelling stations become established. For this to happen there is a need to demonstrate the safety of the refuelling stations. The work described in this paper was carried out to provide experimental information on hydrogen outflow dispersion and explosion behaviour. In the first phase homogeneous hydrogen-air-mixtures of a known concentration were introduced into an explosion chamber and the resulting flame speed and overpressures were measured. Hydrogen concentration was the dominant factor influencing the flame speed and overpressure. Secondly high-pressure hydrogen releases were initiated in a storage room to study the accumulation of hydrogen. For a steady release with a constant driving pressure the hydrogen concentration varied as the inlet airflow changed depending on the ventilation area of the room the external wind conditions and also the buoyancy induced flows generated by the accumulating hydrogen. Having obtained this basic data the realistic dispersion and explosion experiments were executed at full-scale in the hydrogen station model. High-pressure hydrogen was released from 0.8-8.0mm nozzle at the dispenser position and inside the storage room in the full-scale model of the refuelling station. Also the hydrogen releases were ignited to study the overpressures that can be generated by such releases. The results showed that overpressures that were generated following releases at the dispenser location had a clear correlation with the time of ignition distance from ignition point.
Simulation of Flame Acceleration and DDT in H2-air Mixture with a Flux Limiter Centred Method
Sep 2005
Publication
Flame acceleration and deflagration to detonation transition (DDT) is simulated with a numerical code based on a flux limiter centred method for hyperbolic differential equations. The energy source term is calculated by a Riemann solver for the in homogeneous Euler equations for the turbulent combustion and a two-step reaction model for hydrogen-air. The transport equations are filtered for large eddy simulation (LES) and the sub filter turbulence is modelled by a transport equation for the the turbulent kinetic energy. The flame tracking is handled by the G-equation for turbulent flames. Numerical results are compared to pressure histories from physical experiments. These experiments are performed in a closed circular 4m long tube with inner diameter of 0.107m. The tube is filled with hydrogen-air mixture at 1atm which is at rest when ignited. The ignition is located at one end of the tube. The tube is fitted with an obstruction with circular opening 1m down the tube from the ignition point. The obstruction has a blockage ratio of 0.92 and a thickness of 0.01m. The obstruction creates high pressures in the ignition end of the tube and very high gas velocities in and behind the obstruction opening. The flame experiences a detonation to deflagration transition (DDT) in the super sonic jet created by the obstruction. Pressure build-up in the ignition end of the tube is simulated with some discrepancies. The DDT in the supersonic jet is simulated but the position of the DDT is strongly dependent on the simulated pressure in the ignition end.
Modelling of H2 Dispersion and Combustion Phenomena Using CFD Codes
Sep 2005
Publication
Computational Fluid Dynamics codes are increasingly being considered for safety assessment demonstrations in many industrial fields as tools to model accidental phenomena and to design mitigation (risk reducing) systems. Thus they naturally complement experimental programmes which may be expensive to run or difficult to set up. However to trust numerical simulations the validity of the codes must be firmly established and a certain number of error sources (user effect modelling errors discretization errors etc) reduced to the minimum. Code validation and establishment of “best practice guidelines” in the application of simulation tools to hydrogen safety assessment are some of the objectives pursued by the HYSAFE Network of Excellence. This paper will contribute to these goals by describing some of the validation efforts that CEA is making in the areas of release dispersion combustion and mitigation thereby proposing the outline of a validation matrix for hydrogen safety problems.
Numerical Modelling of Hydrogen Release, Mixture and Dispersion in Atmosphere.
Sep 2005
Publication
The method of the numerical solution of a three-dimensional problem of atmospheric release dispersion and explosion of gaseous admixtures is presented. It can be equally applied for gases of different densities including hydrogen. The system of simplified Navie-Stocks equations received by truncation of viscous members (Euler equations with source members) is used to obtain a numerical solution. The algorithm is based on explicit finite-difference Godunov scheme of arbitrary parameters breakup disintegration. To verify the developed model and computer system comparisons of numerical calculations with the published experimental data on the dispersion of methane and hydrocarbons explosions have been carried out. Computational experiments on evaporation and dispersion of spilled liquid hydrogen and released gaseous hydrogen at different wind speeds have been conducted. The largest mass concentrations of hydrogen between the bottom and top limits of flame propagation and cloud borders have been determined. The problem of the explosion of a hydrogen-air cloud of the complex form generated by large-scale spillage of liquid hydrogen and instant release of gaseous hydrogen has been numerically solved at low wind speed. Shock-wave loadings affecting the buildings located on a distance of 52 m from a hydrogen release place have been shown.
A Temperature Controlled Mechanical Test Facility to Ensure Safe Materials Performance in Hydrogen at 1000 Bar
Sep 2007
Publication
Increasingly car manufacturers are turning to high pressure hydrogen storage for on-board power applications. Many prototypes use costly materials and fabrication methods such as Type 316L austenitic stainless steel and processes such as TIG (GTA) welding. There is a need to move to less expensive options without compromising safety to assist in developing economic vehicles. It is important that the behaviour of new/modified materials and joints (including those fabricated by new technologies) is understood at anticipated service temperatures and hydrogen pressure as the consequences of poor material choice could be severe. The greatest detrimental effect of gaseous hydrogen on the mechanical properties of metallic materials is commonly observed under conditions of dynamic plastic strain. Under such conditions an atomically clean surface is produced where hydrogen molecules will dissociate and penetrate the material. Thus static load test methods with hydrogen charging are not reliable for engineering data generation. To meet the need for dynamically straining material in a pressurised hydrogen environment TWI has developed a facility to load specimens in a high pressure environment for tensile toughness and fatigue testing. The design of this has involved a number of innovative steps. This paper outlines the requirements and the design and construction issues that were encountered when installing a facility which can not only perform tests at up to 1000bar (100MPa) but also for temperatures between –150°C to +85°C.
Safety Distances- Definition and Values
Sep 2005
Publication
In order to facilitate the introduction of a new technology as it is the utilization of hydrogen as an energy carrier development of safety codes and standards besides the conduction of demonstrative projects becomes a very important action to be realized. Useful tools of work could be the existing gaseous fuel codes (natural gas and propane) regulating the stationary and automotive applications. Some safety codes have been updated to include hydrogen but they have been based on criteria and/or data applicable for large industrial facilities making the realization of public hydrogen infrastructures prohibitive in terms of space. In order to solve the above mentioned problems others questions come out: how these safety distances have been defined? Which hazard events have been taken as reference for calculation? Is it possible to reduce the safety distances through an appropriate design of systems and components or through the predisposition of adequate mitigation measures? This paper presents an analysis of the definitions of “safety distances” and “hazardous locations” as well as a synoptic analysis of the different values in force in several States for hydrogen and natural gas. The above mentioned synoptic table will highlight the lacks and so some fields that need to be investigated in order to produce a suitable hydrogen standard.
Pool Spreading and Vaporization of Liquid Hydrogen
Sep 2005
Publication
An essential part of a safety analysis to evaluate the risks of a liquid hydrogen (LH2) containing system is the understanding of cryogenic pool spreading and its vaporization. It represents the initial step in an accident sequence with the inadvertent spillage of LH2 e.g. after failure of a transport container tank or the rupture of a pipeline. This stage of an accident scenario provides pertinent information as a source term for the subsequent analysis steps of atmospheric dispersion and at presence of an ignition source the combustion of the hydrogen-air vapor cloud. A computer model LAUV has been developed at the Research Center Juelich which is able to simulate the spreading and vaporization of a cryogenic liquid under various conditions such as different grounds (solid water). It is based on the so-called shallow-layer differential equations taking into account physical phenomena such as ice formation if the cryogen is spilled on a water surface. The presentation will give a description of the computer model and its validation against existing experimental data. Furthermore calculational results will be analyzed describing the prediction and quantification of the consequences of an LH2 spill for different cases. They also include the comparison of an LH2 spillage versus the corresponding release of other cryogens such as liquid natural gas liquid oxygen and liquid nitrogen.
Risk Assessment for Hydrogen Codes and Standards
Sep 2005
Publication
The development and promulgation of codes and standards are essential to establish a market-receptive environment for commercial hydrogen-based products and systems. The focus of the U.S. Department of Energy (DOE) is to conduct the research and development (R&D) needed to strengthen the scientific basis for technical requirements incorporated in national and international standards codes and regulations. In the U.S. the DOE and its industry partners have formed a Codes and Standards Tech Team (CSTT) to help guide the R&D. The CSTT has adopted an R&D Roadmap to achieve a substantial and verified database of the properties and behaviour of hydrogen and the performance characteristics of emerging hydrogen technology applications sufficient to enable the development of effective codes and standards for these applications. However to develop a more structured approach to the R&D described above the CSTT conducted a workshop on Risk Assessment for Hydrogen Codes and Standards in March 2005. The purpose of the workshop was to attain a consensus among invited experts on the protocols and data needed to address the development of risk-informed standards codes and regulations for hydrogen used as an energy carrier by consumers. Participants at the workshop identified and assessed requirements methodologies and applicability of risk assessment (RA) tools to develop a framework to conduct RA activities to address for example hydrogen fuel distribution delivery on-site storage and dispensing and hydrogen vehicle servicing and parking. The CSTT was particularly interested in obtaining the advice of RA experts and representatives of standards and model code developing organizations and industry on how data generated by R&D can be turned into information that is suitable for hydrogen codes and standards development. The paper reports on the results of the workshop and the RA activities that the DOE’s program on hydrogen safety codes and standards will undertake. These RA activities will help structure a comprehensive R&D effort that the DOE and its industry partners are undertaking to obtain the data and conduct the analysis and testing needed to establish a scientific and technical basis for hydrogen standards codes and regulations.
Effect of Carbon Dioxide, Argon and Hydrocarbon Fuels on the Stability of Hydrogen Jet Flames
Sep 2005
Publication
Experimental studies were carried out to examine the lift-off and blow-out stability of H2/CO2 H2/Ar H2/C3H8 and H2/CH4 jet flames. The experiments were carried out using a burner with a 2mm inner diameter. The flame structures were recorded by direct filming and also by a schlieren apparatus. The experiments showed that the four gases affected the lift-off and blow-out stability of the hydrogen differently. The experiments showed that propane addition to an initially attached flame always produced lifted flame and the flame was blown out at higher jet velocity. The blow-out velocity decreased as the increasing in propane concentration. Direct blow-off of hydrogen/propane was never observed. Methane addition resulted in a relatively stable flame comparing with the carbon dioxide and propane addition. Comparisons of the stability of H2/C3H8 H2/CH4 and H2/CO2 flames showed that H2/C3H8 produced the highest lift-off height. Propane is much more effective in lift-off and blow out hydrogen flames. The study carried out a chemical kinetic analysis of H2/CO2 H2/Ar H2/C3H8 and H2/CH4 flames for a comparison of effect of chemical kinetics on flame stability.
Testing of Hydrogen Safety Sensors in Service Simulated Conditions
Sep 2005
Publication
Reliable and effective sensors for the accurate detection of hydrogen concentrations in air are essential for the safe operation of fuel cells hydrogen fuelled systems (e.g. vehicles) and hydrogen production distribution and storage facilities. The present paper describes the activity on-going at JRC for the establishment of a facility that can be used for testing and validating the performance of hydrogen sensors under a range of conditions representative of those to be encountered in service. Potential aspects to be investigated in relation to the sensors performances are the influence of temperature humidity and pressure (simulating variations in altitude) the sensitivity to target gas and the cross sensitivity to other gases/vapours the reaction and recovery time and the sensors’ lifetime. The facility set up at JRC for the execution of these tests is described including the program for its commissioning. The results of a preliminary test are presented and discussed as an example.
A Safety Assessment of Hydrogen Supply Piping System by Use of FDS
Sep 2017
Publication
At least once air filling a piping from main hydrogen pipe line to an individual home end should be replaced with hydrogen gas to use the gas in the home. Special attention is required to complete the replacing operation safely because air and supplied hydrogen may generate flammable/explosive gas mixture in the piping. The most probable method to fulfill the task is that at first an inert gas is used to purge air from the piping and then hydrogen will be supplied into the piping. It is easily understood that the amount of the inert gas consumed by this method is much to purge whole air especially in long piping system. Hence to achieve more economical efficiency an alternative method was considered. In this method previously injected nitrogen between air and hydrogen prevents them from mixing. The key point is that how much nitrogen is required to prevent the dangerous mixing and keep the condition in the piping safe. The authors investigated to find the minimum amount of nitrogen required to keep the replacing operation safe. The main objective of this study is to assess the effect of nitrogen and estimate a pipe length that the safety is maintained under various conditions by using computational fluid dynamic (CFD). The effects of the amount of injected nitrogen hydrogen-supply conditions and the structure of piping system are discussed.
Defining Hazardous Zones – Electrical Classification Distances
Sep 2005
Publication
This paper presents an analysis of computational fluid dynamic models of compressed hydrogen gas leaks into the air under different conditions to determine the volume of the hydrogen/air mixture and the extents of the lower flammable limit. The necessary hole size was calculated to determine a reasonably expected hydrogen leak rate from a valve or a fitting of 5 and 20 cfm under 400 bars resulting in a 0.1 and 0.2 mm effective diameter hole respectively. The results were compared to calculated hypothetical volumes from IEC 60079-10 for the same mass flowrate and in most cases the CFD results produced significantly smaller hydrogen/air volumes than the IEC standard. Prescriptive electrical classification distances in existing standards for hydrogen and compressed natural gas were examined but they do not consider storage pressure and there appears to be no scientific basis for the distance determination. A proposed table of electrical classification distances incorporating hydrogen storage volume and pressure was produced based on the hydrogen LFL extents from a 0.2 mm diameter hole and the requirements of existing standards. The PHOENICS CFD software package was used to solve the continuity momentum and concentration equations with the appropriate boundary conditions buoyancy model and turbulence models. Numerical results on hydrogen concentration predictions were obtained in the real industrial environment typical for a hydrogen refuelling or energy station.<br/><br/>
Innovative Passive Protection Systems For Hydrogen Production Plants
Sep 2005
Publication
As a part of a broader project on hydrogen production by reforming of methane in a membrane catalytic reactor this paper outlines the research activity performed at the University of Pisa Department of Chemical Engineering aimed at developing and testing composite panels that can operate as thermal protective shields against hydrogen jet fires. The shield design criterion that appears to give a more practical and convenient solution for the type of installation to be protected is the one that suggest to realize composite panels. Composite material are made of two elements fiber and matrix. In this study composite panels will be realized with basalt fabric as fiber and epoxy-phenolic resins as matrix. Therefore following the indications given by norms as UNI 9174 and ASTM E 1321-93 a test method has been studied to obtain temperature data from a specimen impinged by an hydrogen flame. Thanks to thermocouples applied on backside of the sample and an infrared video camera to realize thermal images of specimen surface impinged by flame this type of test try to characterize the behaviour of composite materials under the action of hydrogen flame simulating in a simple way the action of hydrogen jet fires.
On Numerical Simulation of Liquefied and Gaseous Hydrogen Releases at Large Scales
Sep 2005
Publication
The large eddy simulation (LES) model developed at the University of Ulster has been applied to simulate releases of 5.11 m3 liquefied hydrogen (LH2) in open atmosphere and gaseous hydrogen (GH2) in 20-m3 closed vessel. The simulations of a spill of liquefied hydrogen confirmed the advantage of LES application to reproduce experimentally observed eddy structure of hydrogen-air cloud. The inclination angle of simulated cloud is close to experimentally reported 300. The processes of two phase hydrogen release and heat transfer were simplified by inflow of gaseous hydrogen with temperature 20 K equal to boiling point. It is shown that difference in inflow conditions geometry and grid resolution affects simulation results. It is suggested that phenomenon of air condensationevaporation in the cloud in temperature range 20-90 K should be accounted for in future. The simulations reproduced well experimental data on GH2 release and transport in 20-m3 vessel during 250 min including a phenomenon of hydrogen concentration growth at the bottom of the vessel. Higher experimental hydrogen concentration at the bottom is assumed to be due to non-uniformity of temperature of vessel walls generating additional convection. The comparison of convective and diffusion terms in Navie-Stokes equations has revealed that a value of convective term is more than order of magnitude prevail over a value of turbulent diffusion term. It is assumed that the hydrogen transport to the bottom of the vessel is driven by the remaining chaotic flow velocities superimposed on stratified hydrogen concentration field. Further experiments and simulations with higher accuracy have to be performed to confirm this phenomenon. It has been demonstrated that hydrogen-air mixture became stratified in about 1 min after release was completed. However one-dimensional models are seen not capable to reproduce slow transport of hydrogen during long period of time characteristic for scenarios such as leakage in a garage.
Gaseous Hydrogen Refueling Stations: Selection Of Materials For High Pressure Hydrogen Fueling Connectors
Sep 2005
Publication
Design of hydrogen fueling components is critical for safety and reliability. Intensive usage of such components in urban public environment is expected in the near future. Any leakage of gas or failure of equipment will create potential hazards. Materials for such category of equipment must have specific mechanical characteristics including hardness (influence on the durability of the equipment and on the resistance to hydrogen) and be easy to machine. Air Liquide has developed a test program for qualifying equipment representing the present state of the art. Studies on the susceptibility of various steels to hydrogen embrittlement have been done. Test specimens were exposed to static and cyclic loads with hydrogen and an inert gas the inert gas representing a reference. Various tests are described here. As a result the importance of further development in the design and selection of appropriate materials for critical hydrogen components is required. Various options are presented and discussed.
Validation of Flacs-Hydrogen CFD Consequence Prediction Model Against Large Scale H2 Explosion Experiments in the Flame Facility
Sep 2005
Publication
The FLACS CFD-tool for consequence prediction has been developed continuously since 1980. The initial focus was explosion safety on offshore oil platforms in recent years the tool is also applied to study dispersion hydrogen safety dust explosions and more. A development project sponsored by Norsk Hydro Statoil and Ishikawajima Heavy Industries (IHI) was carried out to improve the modelling and validation of hydrogen dispersion and explosions. In this project GexCon carried out 200 small-scale experiments on dispersion and explosion with H2 and mixtures with H2 and CO or N2. Experiments with varying confinement congestion concentration and ignition location were performed. Since the main purpose of the tests was to produce good validation data all tests were simulated with the FLACS-HYDROGEN tool. The simulations confirmed the ability to predict explosions effects for the wide range of scenarios studied. A few examples of comparisons will be shown. To build confidence in a consequence prediction model it is important that the scales used for validation are as close as possible to reality. Since the hazard to people and facilities and the risk will generally increase with scale validation against large-scale experiments is important. In the 1980s a series of large-scale explosion experiments with H2 was carried out in the Sandia FLAME facility and sponsored by the US Nuclear Regulatory Commission. The FLAME facility is a 30.5m x 1.83m x 2.44m channel tests were performed with H2 concentrations from 7% to 30% with varying degree of top venting (0% 13% and 50%) and congestion (with or without baffles blocking 33% of the channel cross-section). A wide range of flame speeds and overpressures were observed. Comparisons are made between FLACS simulations and FLAME tests. The main conclusion from this validation study is that the precision when predicting H2 explosion consequences with FLACS has been improved to a very acceptable level
Novel Safe Method Of Manufacturing Hydrogen Metallic Hydrides
Sep 2005
Publication
The present work proposes a novel safe method for obtaining metallic hydrides. The method is called SHS (Self-Propagating High temperature synthesis). A novel high pressure gas reactor governed by an electromechanical control device has been designed and built up in order to synthesise metallic hydrides. This system is provided with a control system that allows calculating the amount of gas coming into the reaction vessel at every stage of the process. The main feature of this method is that metallic hydrides can be safely synthesised using low gas reaction pressures. In order to validate the assessing system the main kinetic regularities of SHS in Ti-H2 system were studied. In addition phase analysis (by means of X ray diffraction) as well as chemical analysis have been performed.
No more items...