Safety
The Possibility of an Accidental Scenario for Marine Transportation of Fuel Cell Vehicle-Hydrogen Releases from TPRD by Radiant Heat From Lower Deck
Oct 2015
Publication
In case fires break out on the lower deck of a car carrier ship or a ferry the fuel cell vehicles (FCVs) parked on the upper deck may be exposed to radiant heat from the lower deck. Assuming that the thermal pressure relief device (TPRD) of an FCV hydrogen cylinder is activated by the radiant heat without the presence of flames hydrogen gas will be released by TPRD to form combustible air-fuel mixtures in the vicinity. To investigate the possibility of this accident scenario the present study investigated the relationship between radiant heat and TPRD activation time and evaluated the possibility of radiant heat causing hydrogen releases by TPRD activation under the condition of deck temperature reaching the spontaneous ignition level of the tires and other automotive parts. It was found: a) the tires as well as polypropylene and other plastic parts underwent spontaneous ignition before TPRD was activated by radiant heat and b) when finally TPRD was activated the hydrogen releases were rapidly burned by the flames of the tires and plastic parts on fire. Consequently it was concluded that the explosion of air-fuel mixtures assumed in the accident scenario does not occur in the real world.
Flame Acceleration and Transition from Deflagration to Detonation in Hydrogen Explosions
Sep 2011
Publication
Computational Fluid Dynamics solvers are developed for explosion modelling and hazards analysis in Hydrogen air mixtures. The work is presented in two parts. These include firstly a numerical approach to simulate flame acceleration and deflagration to detonation transition (DDT) in hydrogen–air mixture and the second part presents comparisons between two approaches to detonation modelling. The detonation models are coded and the predictions in identical scenarios are compared. The DDT model which is presented here solves fully compressible multidimensional transient reactive Navier–Stokes equations with a chemical reaction mechanism for different stages of flame propagation and acceleration from a laminar flame to a highly turbulent flame and subsequent transition from deflagration to detonation. The model has been used to simulate flame acceleration (FA) and DDT in a 2-D symmetric rectangular channel with 0.04 m height and 1 m length which is filled with obstacles. Comparison has been made between the predictions using a 21-step detailed chemistry as well as a single step reaction mechanism. The effect of initial temperature on the run-up distances to DDT has also been investigated. Comparative study has also been carried out for two detonation solvers. one detonation solver is developed based on the solution of the reactive Euler equations while the other solver has a simpler approach based on Chapman–Jouguet model and the programmed CJ burn method. Comparison has shown that the relatively simple CJ burn approach is unable to capture some very important features of detonation when there are obstacles present in the cloud.
Experimental Study of Ignited Unsteady Hydrogen Releases from a High Pressure Reservoir
Sep 2011
Publication
In order to simulate an accidental hydrogen release from the high pressure pipe system of a hydrogen facility a systematic study on the nature of transient hydrogen jets into air and their combustion behavior was performed at the KIT hydrogen test site HYKA. Horizontal unsteady hydrogen jets from a reservoir of 0.37 dm3 with initial pressures of up to 200 bar have been investigated. The hydrogen jets released via round nozzles 3 4 and 10 mm were ignited with different ignition times and positions. The experiments provide new experimental data on pressure loads and heat releases resulting from the deflagration of hydrogen–air clouds formed by unsteady turbulent hydrogen jets released into a free environment. It is shown that the maximum pressure loads occur for ignition in a narrow position and time window. The possible hazard potential arising from an ignited free transient hydrogen jet is described.
Study of Potential Leakage on Several Stressed Fittings for Hydrogen Pressures Up To 700 Bar
Sep 2011
Publication
In order to improve risk analyses and influence the design of the future H2 systems an experimental study on “real” leaks qualification and quantification was performed. In H2 energy applications fittings appeared as a significant leakage potential and subsequently explosion and flame hazards. Thus as a part of the “Horizon Hydrogène Energie” French program four kinds of commercial fittings usually employed on H2 systems were tested thanks to a new high pressure test bench – designed setup and operated by INERIS – allowing experiments to be led for H2 pressures until 700 bar. The fittings underwent defined stresses representative of H2 systems lifetime and beyond. The associated leaks – when existing – are characterized in terms of flow rate.
Determination of Characteristic Parameters for the Thermal Decomposition of Epoxy Resin/carbon Fibre Composites in Cone Calorimeter
Sep 2011
Publication
The thermal degradation of two epoxy resin/carbon fiber composites which differ by their volume fractions in carbon fiber (56 and 59 vol%.) was investigated in cone calorimeter under air atmosphere with a piloted ignition. The external heat flux of cone calorimeter was varied up to 75 kW.m-2 to study the influence of the carbon fiber amount on the thermal decomposition of those composites. Thus main parameters of the thermal decomposition of two different composites were determined such as: mass loss mass loss rate ignition time thermal response parameter ignition temperature critical heat flux thermal inertia and heat of gasification. As a result all the parameters that characterize the thermal resistance of composites are decreased when the carbon fiber volume fraction is increased.
Comparison of NFPA and ISO Approaches for Evaluating Separation Distances
Sep 2011
Publication
The development of a set of safety codes and standards for hydrogen facilities is necessary to ensure they are designed and operated safely. To help ensure that a hydrogen facility meets an acceptable level of risk code and standard development organizations (SDOs) are utilizing risk-informed concepts in developing hydrogen codes and standards. Two SDOs the National Fire Protection Association (NFPA) and the International Organization for Standardization (ISO) through its Technical Committee (TC) 197 on hydrogen technologies have been developing standards for gaseous hydrogen facilities that specify the facilities have certain safety features use equipment made of material suitable for a hydrogen environment and have specified separation distances. Under Department of Energy funding Sandia National Laboratories (SNL) has been supporting efforts by both of these SDOs to develop the separation distances included in their respective standards. Important goals in these efforts are to use a defensible science-based approach to establish these requirements and to the extent possible harmonize the requirements. International harmonization of regulations codes and standards is critical for enabling global market penetration of hydrogen and fuel cell technologies.
New China National Standard on Safety of Hydrogen Systems- Keys for Understanding and Use
Sep 2011
Publication
Development of regulations codes and standards on hydrogen safety is a primary ingredient in overcoming barriers to widespread use of hydrogen energy. Key points of the new China National Standard Essential safety requirements for hydrogen systems metal hydrogen compatibility and risk control of flammability and explosion are discussed. Features of the new standard such as safety requirements for slush hydrogen systems and solid state hydrogen storage systems and introductions for hydrogen production by renewable energy are analyzed in this paper.
Hydrogen Ventilation Test Facility or Underground Mining and Tunneling
Sep 2019
Publication
One of the focus areas in the heavy-duty transport industry globally is de-carbonization of trucks dozers shovels semi-trucks buses etc. Hydrogen fuel cells (FCs) technology is one considered solution for the industry due to its zero-emissions its MW scalability and capacity to store large amounts of energy for long duration continuous power operation. Underground deep mines is another option for deployment and operation of hydrogen FCs. Benefits include lower emissions improved health comfort and safety as well as reduced operating costs. Underground mining trucks loaders and other machines have power ratings up to 750 kW which proves difficult for battery and tethered electric energy. Hydrogen FCs have the ability to overcome these power and energy storage limitations. The risks and technologies associated with delivering storing and using hydrogen underground first need to be investigated and proven safe. This work presents the design construction and operation of a mining ventilation test facility (VTF) at the North-West University in South Africa that aims to quantify the risk of hydrogen in confined ventilated environments. Initial work has been conducted on measuring concentrations of hydrogen released in the temporary ventilation site and is discussed.
CFD Simulations of the Effect of Ventilation on Hydrogen Release Behavior and Combustion in an Underground Mining Environment
Sep 2013
Publication
CFD simulations investigating the effect of ventilation airflow on hydrogen release behaviour in an underground mining tunnel were performed using FLACS hydrogen. Both dispersion and combustion scenarios of a hydrogen release coming from a severed distribution pipeline were investigated. Effects on the hydrogen dispersion such as ventilation strength and the mechanism of air flow supply (a pull or push fan) and mine opening surface roughness surface cavities and obstructions were explored. Results showing the effect of changing the position of the leak adding a cavity on the ceiling of the tunnel and changing the roughness of the walls are given. Overpressure sensitivity to the ignition delay was also considered. From the results for the varied ventilation regimes and spatial scenarios it is difficult to identify the optimal ventilation strategy giving the safest conditions for hydrogen distribution and refuelling in an underground mine.
Effect of the Position and the Area of the Vent on the Hydrogen Dispersion in a Naturally Ventilated Cubiod Space with One Vent on the Side Wall
Dec 2021
Publication
The design of ventilation system has implications for the safety of life and property and the development of regulations and standards in the space with the hydrogen storage equipment. The impact of both the position and the area of a single vent on the dispersion of hydrogen in a cuboid space (with dimensions L x W x H ¼ 2.90 0.74 1.22 m) is investigated with Computational Fluid Dynamics (CFD) in this study. Nine positions of the vent were compared for the leakage taking place at the floor to understand the gas dispersion. It was shown a cloud of 1% mole fraction has been formed near the ceiling of the space in less than 40 s for different positions of the vent which can activate hydrogen sensors. The models show that the hydrogen is removed more effectively when the vent is closer to the leakage position in the horizontal direction. The study demonstrates that the vent height of 1.00 m is safer for the particular scenario considered. The area of the vent has little effect on the hydrogen concentration for all vent positions when the area of the vent is less than 0.045 m2 and the height of the vent is less than 0.61 m.
Hydrogen Storage: Recent Improvements and Industrial Perspectives
Sep 2019
Publication
Efficient storage of hydrogen is crucial for the success of hydrogen energy markets (early markets as well as transportation market). Hydrogen can be stored either as a compressed gas a refrigerated liquefied gas a cryo-compressed gas or in hydrides. This paper gives an overview of hydrogen storage technologies and details the specific issues and constraints related to the materials behaviour in hydrogen and conditions representative of hydrogen energy uses. It is indeed essential for the development of applications requiring long-term performance to have good understanding of long-term behaviour of the materials of the storage device and its components under operational loads.
Risk Analysis on Mobile Hydrogen Refueling Stations in the World Expo Shanghai
Sep 2013
Publication
During the World Expo Shanghai there were one hundred fuel-cell sight-seeing cars in operation at the Expo Site. The sight-seeing cars were not allowed to drive out of the Expo Site and the stationary hydrogen refuelling station was not permitted to build at the Expo Site for the sake of safety. A flexible solution to refuel the cars was the application of mobile hydrogen refuelling stations. To better understand the hazards and risks associated with the mobile hydrogen refueling stations a risk analysis was preformed to improve the safety of the operations. The risks to the station personnel and to the public were discussed separately. Results show that the stationary risks of the mobile stations to the personnel and refueling customers are lower than the risk acceptance criteria over an order of magnitude so occupational risks and risks to customers are completely acceptable. The third party risks can be acceptable as long as the appropriate mitigation measures are implemented especially well designed parking area and operation time. Leak from boosters is the main risk contributor to the stationary risks because of its highest failure rates according to the generic data and its worst harm effects based on the consequence evaluations. As for the road risks of the mobile stations they can be acceptable as long as the appropriate mitigation measures are implemented especially well-designed moving path and transportation time.
Numerical Simulation of Homogenous/Inhomogeneous Hydrogen-air Explosion in a Rectangular Channel
Sep 2019
Publication
Hydrogen is one of the promising energy sources in the future because it has the advantages of clean combustion products high efficiency and renewable energy. However hydrogen has the characteristics of low ignition energy wide flammable range (4% -75%) and fast burning flame speed which can cause explosion hazards. Typically the accidental release of hydrogen into confined or semi confined enclosures can often lead to a flammable hydrogen-air mixture with concentration gradients and possible flame acceleration and deflagration-to-detonation transition (DDT). The present study aims to test the capability of our in-house density-based solver ExplosionEngFoam for flame acceleration (FA) and deflagration-to-detonation transition (DDT) in homogenous/inhomogeneous hydrogen-air mixtures. The solver is based on the open source computational fluid dynamics (CFD) platform OpenFOAM and uses the modified Weller et al.’s combustion model taking into account LD and RT instabilities turbulence and non-unity Lewis number etc. Numerical simulations were conducted for both homogeneous and inhomogeneous mixtures in a long enclosed channel with 5.4 m in length and 0.06 m in height. The predictions demonstrate good quantitative agreement with the experimental measurements in flame tip position speed and pressure profiles by Boeck et al. The flow characteristics such as flame fine structure wave evolution etc. were also discussed.
Vapour Cloud Explosions from the Ignition of Methane, Hydrogen, Air Mixtures in a Congested Region
Sep 2007
Publication
To facilitate the transition to the hydrogen economy the EU project NATURALHY is studying the potential for the existing natural gas pipeline networks to transport hydrogen together with natural gas to end-users. Hydrogen may then be extracted for hydrogen fuel-cell applications or the mixture used directly by consumers in existing gas-fired equipment with the benefit of lower carbon emissions. The existing gas pipeline networks are designed constructed and operated to safely transport natural gas mostly methane. However hydrogen has significantly different properties that may adversely affect both the integrity of the network and thereby increase the likelihood of an accidental leak and the consequences if the leak finds a source of ignition. Consequently a major part of the NATURALHY project is focused on assessing how much hydrogen could be introduced into the network without adversely impacting on the safety of the network and the risk to the public. Hydrogen is more reactive than natural gas so the severity of an explosion following an accidental leak may be increased. This paper describes field-scale experiments conducted to measure the overpressures generated by ignition of methane/hydrogen/air mixtures in a congested but unconfined region. Such regions may be found in the gas handling and metering stations of the pipeline networks. The 3 m x 3 m x 2 m high congested region studied contained layers of pipes. The composition of the methane/hydrogen mixture used was varied from 0% hydrogen to 100% hydrogen. On the basis of the experiments performed the maximum overpressures generated by methane/hydrogen mixtures with 25% (by volume) or less hydrogen content are not likely to be much more than those generated by methane alone. Greater percentages of hydrogen did significantly increase the explosion overpressure.
Safe Operation of Natural Gas Appliances Fuelled with Hydrogen & Natural Gas Mixtures (Progress Obtained in the Naturalhy-Project)
Sep 2007
Publication
Considering the transition towards the hydrogen economy dependent on hydrogen penetration scenario the cost of a new hydrogen pipeline infrastructure in Europe may amount to several thousands of billions of EURO’s. Therefore the examination of the potential contribution of the existing natural gas assets is a practical and logical first step. As the physical and chemical properties of hydrogen differ significantly from those of natural gas it is not at all possible to simply exchange natural gas by hydrogen in the existing infrastructure. In this paper first a brief overview will be given of the NATURALHY-project. Further the focus will be on the impact of added hydrogen on the performance of existing natural gas domestic end user appliances which is related to the operation of the natural gas grid connecting the different types of appliance. The application of the fundamental insights and carefully designed experiments comparing the behaviour of gases using justified reference conditions have been shown to offer essential progress. The Wobbe index limits of the natural gas distributed pose a first limiting factor upon the maximum allowable hydrogen concentration. Constant-Wobbe index and decreasing-Wobbe index options of H2 admixture have been studied. Considering the appliance light back H2 limiting factor for domestic appliances fuel-rich appliances are the critical ones. Also taking into account stationary gas engines gas turbines industrial applications and natural gas grid management it is not yet justified to present statements on what level of hydrogen concentration could be safely allowed in which specific natural gas distribution region. But more clarity has been obtained on combustion safety aspects of existing domestic appliances on the connection with Wobbe distribution conditions and on the bottlenecks still to be handled.
Potential for Hydrogen Production from Biomass Residues in the Valencian Community
Sep 2007
Publication
The production of hydrogen from renewable sources is essential to develop the future hydrogen economy. Biomass is an abundant clean and renewable energy source and it can be important in the production of hydrogen. The Valencian Community due to its great agricultural and forestry activities generates an important quantity of biomass residues that can be used for energy generation approximately 778 kt of wet biomass residues per year. This great quantity of biomass can be transformed into a hydrogen-rich gas by different thermochemical conversion processes. In this article the potential of production of hydrogen-rich gas is analyzed considering several factors affecting the conversion yield of these processes. As a result of this analysis it could be possible to produce 1271 MNm3 of H2 per year considering the total biomass residues of the community and selecting the gasification processes.
Hydrogen Subsonic Upward Release and Dispersion Experiments in Closed Cylindrical Vessel
Sep 2007
Publication
Report presents the preliminary experimental results on hydrogen subsonic leakage in a closed vessel under the well-controlled boundary/initial conditions. Formation of hydrogen-air gas mixture cloud was studied for a transient (10 min) upward hydrogen leakage which was followed by subsequent evolution (15 min) of explosive cloud. Low-intensity ( 0.46⋅10−3 m3/sec) hydrogen release was performed via circular (diameter 0.014 m) orifice located in the bottom part of a horizontal cylindrical vessel ( ≈4 m3). A spatially distributed net of the 24 hydrogen sensors and 24 temperature sensors was used to permanently track the time dependence of the hydrogen concentration and temperature fields in vessel. Analysis of the simultaneous experimental records for the different spatial points permits to delineate the basic flow patterns and stages of hydrogen subsonic release in closed vessel in contrast to hydrogen jet release in open environment. The quantitative data were obtained for the averaged speeds of explosive cloud envelop (50% fraction of the Lower Flammability Limit (LFL)) propagation in the vertical and horizontal directions. The obtained data will be used as an experimental basis for development of the guidelines for an indoors allocation of the hydrogen sensors. Data can be also used as a new benchmark case for the reactive Computational Fluid Dynamics codes validation.
On the Use of Spray Systems- An Example of R&D Work in Hydrogen Safety for Nuclear Applications
Sep 2007
Publication
The aim of the present work is to investigate the interaction between a water spray and a laminar hydrogen-air flame in the case of steam inerted mixture. A first work is devoted to study the thermodynamics involved in the phenomena via a lumped parameter code. The flow is two- phase and reactive the gas is multi-component the water spray is polydisperse and the droplet size has certainly an influence on the flame propagation. The energy released by the reaction between hydrogen and oxygen vaporizes suspended droplets. The next step of this study will be to consider a drift-flux model for the droplets and air under hypotheses that the velocity and thermal disequilibria are weak. The multi-component feature of the gas will be further taken into account by studying a gas mixture containing hydrogen air and water vapor. A second study concerns an experimental investigation of the effect of droplets on the flame propagation using a spherical vessel. A Schlieren system is coupled to the spherical vessel in order to record the flame propagation on a digital high speed camera. Both studies will help improve our knowledge of safety relevant phenomena.
Fire Protection Strategy for Compressed Hydrogen-Powered Vehicles
Sep 2007
Publication
Virtually all major automotive companies are currently developing hydrogen-powered vehicles. The vast majority of them employ compressed hydrogen tanks and components as a means of storing the fuel onboard. Compressed hydrogen vehicle fuel systems are designed in the same way as compressed natural gas vehicles (NGV) i.e. the high pressure (up to 70 MPa) fuel is always contained within the system under all conditions with the exception of vehicular fire. In the event of a vehicle fire the fuel system is protected using a non-reclosing thermally activated pressure relief device (PRD) which safely vents the contents. Hydrogen fuel system PRDs are presently qualified to the performance requirements specified in draft hydrogen standards such ANSI/CSA HPRD 1 and EIHP Rev. 12b. They are also qualified with individual fuel tank designs in accordance with the engulfing bonfire requirements in various published/draft tank standards such as CSA B51 Part 2 JARI S001 SAE TIR J2579 ANSI/CSA HGV 2 ISO DIS 15869.2 and EIHP Rev. 12b. Since 2000 there have been over 20 documented NGV tank failures in service 11 of which have been attributed to vehicle fires. This paper will examine whether currently proposed hydrogen performance standards and installation requirements offer suitable fuel system protection in the event of vehicular fires. A number of alternative fire protection strategies will be discussed including:
- The requirement of an engulfing and/or localized fire test for individual tanks fuel systems and complete vehicles;
- The advantages/disadvantages of point source- surface area- and/or fuse-based PRDs
- The use of thermal insulating coatings/blankets for fire protection resulting in the NONventing of the fuel
- The specification of appropriate fuel system installation requirements to mitigate the effect of vehicular fires.
Assessing the Durability and Integrity of Natural Gas Infrastructures for Transporting and Distributing Mixtures of Hydrogen and Natural Gas
Sep 2005
Publication
Extensive infrastructure exists for the transport of natural gas and it is an obvious step to assess its use for the movement of hydrogen. The Naturalhy project’s objective is to prepare the European natural gas industry for the introduction of hydrogen by assessing the capability of the natural gas infrastructure to accept mixtures of hydrogen and natural gas. This paper presents the ongoing work within both Durability and Integrity Work Packages of the Naturalhy project. This work covers a gap in knowledge on risk assessment required for delivering H2+natural gas blends by means of the existing natural gas grids in safe operation.<br/>Experiments involving several parts of the existing infrastructure will be described that are being carried out to re-examine the major risks previously studied for natural gas including: effect of H2 on failure behaviour and corrosion of transmission pipes and their burst resistance (link to the Work Package Safety) on permeability and ageing of distribution pipes on reliability and ageing of domestic gas meters tightness to H2 of domestic appliances and their connexions. The information will be integrated into existing Durability assessment methodologies originally developed for natural gas.<br/>An Integrity Management Tool will be developed taking account of the effect of hydrogen on the materials properties. The tool should enable a cost effective selection of appropriate measures to control the structural integrity and maintaining equipment. The main measures considered are monitoring non destructive examination (pigging and non pigging) and repair strategies. The tool will cover a number of parameters e.g.: percentage of hydrogen in the gas mixture material of construction operating conditions and condition of cathodic protection. Thus the Integrity Management Tool will yield an inspection and maintenance plan based on the specific circumstances.