France
Defect Assessment on Pipe Used For Transport of Mixture of Hydrogen and Natural Gas
Sep 2009
Publication
The present article indicates the change of mechanical properties of X52 gas pipe steel in presence of hydrogen and its consequence on defect assessment particularly on notch like defects. The purpose of this work is to determine if the transport of a mixture of natural gas and hydrogen in the actual existing European natural gas pipe network can be done with a reasonable low failure risk (i.e. a probability of failure less than 10-6). To evaluate this risk a deterministic defect assessment method has been established. This method is based on Failure Assessment Diagram and more precisely on a Modified Notch Failure Assessment Diagram (MNFAD) which has been proposed for this work. This MNFAD is coupled with the SINTAP failure curve and allows determining the safety factor associated with defect geometry loading conditions and material resistance. The work described in this paper was performed within the NATURALHY work package 3 on ’Durability of pipeline material’.
Hydrogen Effect on Fatigue and Fracture of Pipe Steels
Sep 2009
Publication
Transport by pipe is one the most usual way to carry liquid or gaseous energies from their extraction point until their final field sites. To limit explosion risk or escape to avoid pollution problems and human risks it is necessary to assess nocivity of defect promoting fracture. This need to know the mechanical properties of the pipes steels. Hydrogen is considered to day as a new energy vector and its transport in one of the key problems to extension of its use. Within the European project NATURALHY it has been proposed to transport a mixture of natural gas and hydrogen. 39 European partners have combined their efforts to assess the effects of hydrogen presence on the existing gas network. Key issues are durability of pipeline material integrity management safety aspects life cycle and socio-economic assessment and end-use. The work described in this paper was performed within the NATURALHY work package on ’Durability of pipeline material’. This study makes it possible to emphasize the hydrogen effect on mechanical properties of several pipe steels as X52 X70 or X100 in fatigue and fracture and in two different environments: air and hydrogen electrolytic.
CFD Benchmark Based on Experiments of Helium Dispersion in a 1m3 Enclosure–intercomparisons for Plumes
Sep 2013
Publication
In the context of the French DIMITRHY project ANR-08-PANH006 experiments have been carried out to measure helium injections in a cubic 1 m3 box - GAMELAN in a reproducible and quantitative manner. For the present work we limit ourselves to the unique configuration of a closed box with a small hole at its base to prevent overpressure. This case leads to enough difficulties of modelisations to deserve our attention. The box is initially filled with air and injections of helium through a tube of diameter 20 mm is operated. The box is instrumented with catharometres to measure the helium volume concentration within an accuracy better than 0.1%. We present the CFD (Fluent and CASTEM ANSYS-CFX and ADREA-HF) calculations results obtained by 5 different teams participating to the benchmark in the following situation: the case of a plume release of helium in a closed box (4NL/min). Parts of the CFD simulations were performed in the European co-funded project HyIndoor others were performed in the French ANR-08-PANH006 DimitrHy project.
Material Testing and Design Recommendations for Components Exposed to Hydrogen Enhanced Fatigue – the Mathryce Project
Sep 2013
Publication
The three years European MATHRYCE project dedicated to material testing and design recommendations for components exposed to hydrogen enhanced fatigue started in October 2012. Its main goal is to provide an “easy” to implement methodology based on lab-scale experimental tests under hydrogen gas to assess the service life of a real scale component taking into account fatigue loading under hydrogen gas. Dedicated experimental tests will be developed for this purpose. In the present paper the proposed approach is presented and compared to the methodologies currently developed elsewhere in the world.
Influence of the Location of a Buoyant Gas Release in Several Configurations Varying the Height of the Release and the Geometry of the Enclosure
Sep 2013
Publication
The present work proposes a parametric study on the influence of the height of the release source on the helium dispersion regimes inside a naturally ventilated enclosure. Several configurations were experimentally addressed in order to improve knowledge on dispersion considering conditions close to hydrogen energy systems in terms of operating characteristics and design. Thus the varying parameters of the study were mainly the height of the release and also the releasing flow rate the volume and the geometry of the enclosure. Experimental results were compared to existing analytical models and considered through model improvements allowing a better approach of these specific cases for hydrogen systems risk assessment.
Hydrogen Storage: Recent Improvements and Industrial Prospective
Oct 2015
Publication
Efficient storage of hydrogen is crucial for the success of hydrogen energy markets (early markets as well as transportation market). Hydrogen can be stored either as a compressed gas a refrigerated liquefied gas a cryo-compressed gas or in hydrides. This paper gives an overview of hydrogen storage technologies and details the specific issues and constraints related to the materials behaviour in hydrogen and conditions representative of hydrogen energy uses. It is indeed essential for the development of applications requiring long-term performance to have good understanding of long-term behaviour of the materials of the storage device and its components under operational loads.
European Hydrogen Safety Training Platform for First Responders- Hyresponse Project
Sep 2013
Publication
The paper presents HyResponse project i.e. a European Hydrogen Safety Training Platform that targets to train First responders to acquire professional knowledge and skills to contribute to FCH permitting process as approving authority. The threefold training program is described: educational training operational-level training on mock-up real scale transport and hydrogen stationary installations and innovative virtual training exercises reproducing entire accident scenarios. The paper highlights how the three pilot sessions for European First Responders in a face to face mode will be organized to get a feedback on the training program. The expected outputs are also presented i.e. the Emergency Response Guide and a public website including teaching material and online interactive virtual training.
Probability of Occurrence of ISO 14687-2 Contaminants in Hydrogen: Principles and Examples from Steam Methane Reforming and Electrolysis (Water and Chlor-alkali) Production Processes Model
Apr 2018
Publication
According to European Directive 2014/94/EU hydrogen providers have the responsibility to prove that their hydrogen is of suitable quality for fuel cell vehicles. Contaminants may originate from hydrogen production transportation refuelling station or maintenance operation. This study investigated the probability of presence of the 13 gaseous contaminants (ISO 14687-2) in hydrogen on 3 production processes: steam methane reforming (SMR) process with pressure swing adsorption (PSA) chlor-alkali membrane electrolysis process and water proton exchange membrane electrolysis process with temperature swing adsorption. The rationale behind the probability of contaminant presence according to process knowledge and existing barriers is highlighted. No contaminant was identified as possible or frequent for the three production processes except oxygen (frequent for chlor-alkali membrane process) carbon monoxide (frequent) and nitrogen (possible) for SMR with PSA. Based on it a hydrogen quality assurance plan following ISO 19880-8 can be devised to support hydrogen providers in monitoring the relevant contaminants.
High Pressure Hydrogen Fires
Sep 2009
Publication
Within the scope of the French national project DRIVE and European project HyPER high pressure jet flames of hydrogen were produced and instrumented.<br/>The experimental technique and measurement strategy are presented. Many aspects are original developments like the direct measurement of the mass flow rate by weighing continuously the hydrogen container the image processing to extract the flame geometry the heat flux measurement device the thermocouples arrangement…<br/>Flames were observed from 900 bar down to 1 bar with orifices ranging from 1 to 3 mm. An original set of data is now available about the main flame characteristics and about some thermodynamic aspects of hydrogen releases under high pressure.<br/>A brief comparison of some available models is presented.
Data for the Evaluation of Hydrogen Risks Onboard Vehicles: Outcomes from the French Project Drive
Sep 2011
Publication
From 2006 to 2009 INERIS alongside with CEA PSA PEUGEOT CITROËN and IRPHE were involved in a project called DRIVE. Its objective was to provide data on the whole reaction chain leading to a hydrogen hazard onboard a vehicle. Out of the three types of leakage identified by the consortium (permeation chronic and accidental) the chronic leakage taking place within the engine was judged to be more problematic since it can feature a high probability of occurrence and a significant release flow rate (up to 100 NL/min). Ignition tests carried out within a real and dummy engine compartment showed that pressure effects due to an explosion will be relatively modest provided that the averaged hydrogen concentration in this area is limited to 10% vol/vol which would correspond to a maximum release flow of 10 NL/min. This maximum concentration could be used as a threshold value for detection or as a target while designing the vehicle. Jet fire experiments were also conducted in the frame of the DRIVE project. It was found that pressure-relief devices (PRDs) might be unsuited to protect humans from the explosion of a tank caused by a bonfire. Other solutions are proposed in this paper.
Syngas Explosion Reactivity in Steam Methane Reforming Process
Sep 2013
Publication
During the synthesis of hydrogen by methane steam reforming mixtures composed of H2 CH4 CO and CO2 are produced in the process. In this work the explosion reactivity of these mixtures on the basis of detonation cell size and laminar flame speed is calculated using a reactant assimilation simplification and a kinetic approach. The detonation cells width are calculated using the Cell_CH Kurchatov institute method and the laminar flame velocities are calculated with Chemkin Premix using different detailed chemical kinetic mechanisms. These calculations are used to define if these mixtures could be considered having a medium or a high reactivity for risk assessment in case of leak in the hydrogen plants.
Hydrogen Storage – Industrial Prospectives
Sep 2011
Publication
The topic of this paper is to give an historical and technical overview of hydrogen storage vessels and to detail the specific issues and constraints of hydrogen energy uses. Hydrogen as an industrial gas is stored either as a compressed or as a refrigerated liquefied gas. Since the beginning of the last century hydrogen is stored in seamless steel cylinders. At the end of the 60 s tubes also made of seamless steels were used; specific attention was paid to hydrogen embrittlement in the 70 s. Aluminum cylinders were also used for hydrogen storage since the end of the 60 s but their cost was higher compared to steel cylinders and smaller water capacity. To further increase the service pressure of hydrogen tanks or to slightly decrease the weight metallic cylinders can be hoop-wrapped. Then with specific developments for space or military applications fully-wrapped tanks started to be developed in the 80 s. Because of their low weight they started to be used in for portable applications: for vehicles (on-board storages of natural gas) for leisure applications (paint-ball) etc… These fully-wrapped composite tanks named types III and IV are now developed for hydrogen energy storage; the requested pressure is very high (from 700 to 850 bar) leads to specific issues which are discussed. Each technology is described in term of materials manufacturing technologies and approval tests. The specific issues due to very high pressure are depicted. Hydrogen can also be stored in liquid form (refrigerated liquefied gases). The first cryogenic vessels were used in the 60s. In the following the main characteristics of this type of storage will be indicated.
Experimental Determination of Minimum Ignition Current (MIC) for Hydrogen & Methane Mixtures for the Determination of the Explosion Group Corresponding to IEC 60079-20-1
Sep 2017
Publication
Power to gas could get an important issue in future permitting the valorisation of green electric excess energy by producing hydrogen mixing it with natural gas (NG) and use the NG grid as temporary storage. NG grid stakeholders expect that blends up to 20% seem to be a realistic scenario. The knowledge of the explosion group for these hydrogen/NG (H2NG) mixtures is a necessary information for the choice of equipment and protective systems intended for the use in potentially explosive atmospheres of these mixtures. Therefore we determined experimentally the minimum ignition current (MIC) the MIC ratios referenced on MIC of pure methane corresponding to IEC 60079-20-1 standard. The results are compared to those obtained by maximum experimental safe gap (MESG) the second standardized method. The tested gas mixtures started from 2 vol.% volume admixture in methane rising in 2% steps up to 20 vol.% of hydrogen. The interpretation of these results could conduct to consider methane/hydrogen mixtures containing more than 14 vol.% of hydrogen as Group IIB gases.
Hydrogen Ironmaking: How It Works
Jul 2020
Publication
A new route for making steel from iron ore based on the use of hydrogen to reduce iron oxides is presented detailed and analyzed. The main advantage of this steelmaking route is the dramatic reduction (90% off) in CO2 emissions compared to those of the current standard blast-furnace route. The first process of the route is the production of hydrogen by water electrolysis using CO2-lean electricity. The challenge is to achieve massive production of H2 in acceptable economic conditions. The second process is the direct reduction of iron ore in a shaft furnace operated with hydrogen only. The third process is the melting of the carbon-free direct reduced iron in an electric arc furnace to produce steel. From mathematical modeling of the direct reduction furnace we show that complete metallization can be achieved in a reactor smaller than the current shaft furnaces that use syngas made from natural gas. The reduction processes at the scale of the ore pellets are described and modeled using a specific structural kinetic pellet model. Finally the differences between the reduction by hydrogen and by carbon monoxide are discussed from the grain scale to the reactor scale. Regarding the kinetics reduction with hydrogen is definitely faster. Several research and development and innovation projects have very recently been launched that should confirm the viability and performance of this breakthrough and environmentally friendly ironmaking process.
Effects of Oxidants on Hydrogen Spontaneous Ignition: Experiments and Modelling
Sep 2017
Publication
Experiments were performed on the influence of oxidants (air pure oxygen O2 and pure nitrous oxide N2O at atmospheric pressure) in the straight expansion tube after the burst disk on the hydrogen spontaneous ignition. The lowest pressure at which the spontaneous ignition is observed has been researched for a 4 mm diameter tube with a length of 10 cm for the two oxidant gases. The ignition phenomenon is observed with a high speed camera and the external overpressures are measured. Numerical simulations have also been conducted with the high resolution CFD approach detailed chemistry formerly developed by Wen and co-workers. Comparison is made between the predictions and the experimental data.
Experimental Study of the Concentration Build-Up Regimes in an Enclosure Without Ventilation
Sep 2011
Publication
We present an experimental investigation of the different concentration build-up regimes encountered during a release of helium/air mixture in an empty enclosure without ventilation. The release is a vertical jet issuing from a nozzle located near the floor. The nozzle diameter the flow rate and the composition of the injected mixture have been varied such that the injection Richardson number ranges from 6 × 10−6 to 190. The volume Richardson number which gives the ability of the release to mix the enclosure content ranges from 2 × 10−3 to 2 × 104. This wide range allowed reaching three distinct regimes: stratified stratified with a homogeneous upper layer and homogenous.
Safety of Hydrogen and Natural Gas Mixtures by Pipelines- ANR French Project Hydromel
Sep 2011
Publication
In order to gain a better understanding of hazards linked with Hydrogen/Natural gas mixtures transport by pipeline the National Institute of Industrial Environment and Risks (INERIS) alongside with the Atomic Energy Commission (CEA) the industrial companies Air Liquide and GDF SUEZ and the French Research Institutes ICARE and PPRIME (CNRS) have been involved in a project called HYDROMEL. This project was partially funded by the French National Research Agency (ANR) in the framework of its PAN-H program aimed at promoting the R&D activities related to the hydrogen deployment. Firstly the project partners investigated how a NG/H2 mixture may influence the modelling of a hazard scenario i.e. how the addition of a quantity of hydrogen in natural gas can increase the potential of danger. Therefore it was necessary to build an experimental database of physics properties for mixtures. Secondly effect distances in accidental scenarios that could happen on pipelines have been calculated with existing models adapted to the mixtures. This part was preceded by a benchmark exercise between all partners models and experimental results found in the literature. Finally the consortium wrote a good practice guideline for modelling the effects related to the release of natural gas /hydrogen mixture?. The selected models and their comparison with data collected in the literature as well as the experimental results of this project and the main conclusions of the guidelines are presented in this paper.
Influence of Initial Pressure in Hydrogen/Air flame Acceleration During Severe Accident in Nuclear Power Plant
Sep 2017
Publication
Flame acceleration (FA) and explosion of hydrogen/air mixtures remain key issues for severe accident management in nuclear power plants. Empirical criteria were developed in the early 2000s by Dorofeev and colleagues providing effective tools to discern possible FA or DDT (Deflagration-to-Detonation Transition) scenarios. A large experimental database composed mainly of middle-scale experiments in obstacle-laden ducts at atmospheric pressure condition has been used to validate these criteria. However during a severe accident the high release rate of steam and non-condensable gases into the containment can result in pressure increase up to 5 bar abs. In the present work the influence of the unburnt gas initial pressure on flame propagation mechanisms was experimentally investigated. Premixed hydrogen/air mixtures with hydrogen concentration close to 11% and 15% were considered. From the literature we know that these flames are supposed to accelerate up to Chapman-Jouguet deflagration velocity in long obstacle-laden tubes at initial atmospheric conditions. Varying the pressure in the fresh gas in the range 0.6–4 bar no effects on the flame acceleration phase were observed. However as the initial pressure was increased we observed a decrease in the flame velocity close to the end of the tube. The pressure increase due to the combustion reaction was found to be proportional to the initial pressure according to adiabatic isochoric complete combustion.
Turbulent Flame Propagation in Large Unconfined H2/O2/N2 Clouds
Oct 2015
Publication
Turbulence is a key aspect in hydrogen explosions. Unfortunately only limited experimental data is available and the current understanding of flame turbulence interactions is too limited to permit safe predictions. New experimental data are presented in which the flame trajectory and pressure history are interpreted for unconfined explosions of H2/O2/N2 clouds of 7 m3. The intensity of the turbulence is varied between 0 and 5 m/s and the integral scale of the turbulence is on the order of 10 cm which is at least an order of magnitude larger than lab scale.
Comparative Study of Regulations, Codes and Standards and Practices on Hydrogen Fuelling Stations
Oct 2015
Publication
This work deals with a comparative study of regulations codes and standards for hydrogen fuelling station dedicated for light duty land vehicles in the following countries: United States (California) United Kingdom Italy Germany Canada Sweden Norway Denmark and Spain.<br/>The following technical components of a hydrogen fuelling station are included in the scope of the study: the hydrogen storage systems (cryogenic or compressed gases) and buffer storage the compressor stations the high pressure buffer storage the cooling systems for hydrogen the dispensing equipments and the dispensing area. The hydride storage the pipelines on site production and the hydrogen vehicle have been excluded.<br/>The analysis performed in September 2014 in a report from INERIS DRA-14-141532-06227C BENCHMARK STATIONS-SERVICE HYDROGENE is based on documents collected by bibliographic review and information obtained through a questionnaire sent to authorities and IA HySafe members in the above mentioned countries.<br/>This paper gives a synthesis of the regulations and on permitting process in the different studied countries (including the new European Directive on the deployment of alternative fuels infrastructure in Europe) it develops the required safety barriers in the different parts of a fuelling station and specially for the dispensing area gives an overview of the different approaches for safety distances and processes to obtain licences to operate.
Numerical Simulation of the Helium Dispersion in a Semi-confined Air-filled Cavity
Sep 2013
Publication
This paper deals with the build-up of concentration when a continuous source of helium is supplied in an air-filled enclosure. Our aim is to reproduce the results of a small-scale experimental study. To begin with the size of the experiment is reduced from 1/10 to 3/5 for the present analysis. Hypotheses are made in order to reduce the dimension of the real problem. Numerical simulations are carried out on fine grids without any turbulence modelling. The flow structure and the concentration profile of the resulting flow are analyzed and compared with theoretical results.
Experimental Results on The Dispersion of Buoyant Gas in a Full Scale Garage from a Complex Source
Sep 2009
Publication
The lack of experimental data on hydrogen dispersion led to the experimental project DRIVE (Experimental Data for Hydrogen Automotive Risks Assessment for the validation of numerical tools and for the Edition of guidelines) that involves the CEA (French Atomic Energy Commission) the National Institute of Industrial Environment and Risks (INERIS) the French car manufacturer PSA PEUGEOT CITROËN and the Research Institute on Out of Equilibrium Phenomena (IRPHE). The CEA has developed an experimental setup named GARAGE in order to analyze the condition of formation of an explosive atmosphere in an enclosure. This is a full scale facility in which a real car can be parked. Hydrogen releases were simulated with helium which volume fraction was measured with mini-katharometers. These thermal conductivity probes allow spatial and time volume fraction variations measurements. We present experimental results on the dispersion of helium in the enclosure due to releases in a typical car. The tested parameters are the location of the source (engine bottom of the car storage) and the flow rate. Emphasis is put on the influence of these parameters on the time evolution of the volume fraction in the enclosure as well as on the vertical distribution of helium.
Study of Potential Leakage on Several Stressed Fittings for Hydrogen Pressures Up To 700 Bar
Sep 2011
Publication
In order to improve risk analyses and influence the design of the future H2 systems an experimental study on “real” leaks qualification and quantification was performed. In H2 energy applications fittings appeared as a significant leakage potential and subsequently explosion and flame hazards. Thus as a part of the “Horizon Hydrogène Energie” French program four kinds of commercial fittings usually employed on H2 systems were tested thanks to a new high pressure test bench – designed setup and operated by INERIS – allowing experiments to be led for H2 pressures until 700 bar. The fittings underwent defined stresses representative of H2 systems lifetime and beyond. The associated leaks – when existing – are characterized in terms of flow rate.
Numerical Investigation of a Mechanical Device Subjected to a Deflagration-to-detonation Transition
Sep 2011
Publication
In this work we evaluate the consequences of the combustion of a stoichiometric mixture of hydrogen-air on a mechanical device which can be considered as a long tube. In order to choose the most dangerous combustion regime for the mechanical device we devote a particular attention to the investigation of the 1D deflagration-to-detonation transition. Then once established the most dangerous combustion regime we compute the reacting flow and the stress and strain in the mechanical device. Analyses are performed using both semi-analytical solutions and Europlexus a computer program for the simulation of fluid-structure systems under transient dynamic loading.
Isotopic Tracing of Hydrogen Transport and Trapping in Nuclear Materials
Jun 2017
Publication
Some illustrations of the use of deuterium or tritium for isotopic tracing of hydrogen absorption transport and trapping in nuclear materials are presented. Isotopic tracing of hydrogen has been shown to be successful for the determination of the boundaries conditions for hydrogen desorption or absorption in a material exposed to a hydrogen source. Also the unique capabilities of isotopic tracing and related techniques to characterize H interactions with point defects and dislocations acting as moving traps has been demonstrated. Such transport mechanisms are considered to play a major role in some stress corrosion cracking and hydrogen embrittlement mechanisms.
Link to document download on Royal Society Website
Link to document download on Royal Society Website
Numerical Study of the Near-field of Highly Under-expanded Turbulent Gas Jets
Sep 2011
Publication
For safety issues related to the storage of hydrogen under high pressure it is necessary to determine how the gas is released in the case of failure. In particular there exist limited quantitative information on the near-field properties of the gas jets which are important for establishing proper decay laws in the far-field. This paper reports recent CFD results for air and helium obtained in the near-field of the highly under-expanded jets. The gas jets are released from a 30-bar tank with the same opening (orifice). The Reynolds number based on the diameter of the orifice and corresponding gas conditions at the exit was well beyond 106 . The 3D Compressible Multi-Component Navier-Stokes equations were solved directly without relying on the compressibility-corrected turbulence models. The numerical model was initially tested on a one-component (air-air) case where a few aerospace-driven data sets are available for validation. The shock geometry is characterized through the Mach disk position and diameter. These are compared to the results known from the literature and to the scaling laws developed based on the dimensional analysis. In the second two-component (helium-air) jet scenario the density field was validated and examined together with other fields in the attempt to suggest potential initial conditions for the forthcoming far-field simulations.
Prevention of Hydrogen Accumulation Inside the Vacuum Vessel Pressure Suppression System of the ITER Facility by Means of Passive Auto-catalytic Recombiners
Sep 2017
Publication
Hydrogen safety is a relevant topic for both nuclear fission and fusion power plants. Hydrogen generated in the course of a severe accident may endanger the integrity of safety barriers and may result in radioactive releases. In the case of the ITER fusion facility accident scenarios with water ingress consider the release of hydrogen into the suppression tank (ST) of the vacuum vessel pressure suppression system (VVPSS). Under the assumption of additional air ingress the formation of flammable gas mixtures may lead to explosions and safety component failure.<br/>The installation of passive auto-catalytic recombiners (PARs) inside the ST which are presently used as safety devices inside the containments of nuclear fission reactors is one option under consideration to mitigate such a scenario. PARs convert hydrogen into water vapor by means of passive mechanisms and have been qualified for operation under the conditions of a nuclear power plant accident since the 1990s.<br/>In order to support on-going hydrogen safety considerations simulations of accident scenarios using the CFD code ANSYS-CFX are foreseen. In this context the in-house code REKO-DIREKT is coupled to CFX to simulate PAR operation. However the operational boundary conditions for hydrogen recombination (e.g. temperature pressure gas mixture) of a fusion reactor scenario differ significantly from those of a fission reactor. In order to enhance the code towards realistic PAR operation a series of experiments has been performed in the REKO-4 facility with specific focus on ITER conditions. These specifically include operation under sub-atmospheric pressure (0.2–1.0 bar) gas compositions ranging from lean to rich H2/O2 mixtures and superposed flow conditions.<br/>The paper gives an overview of the experimental program presents results achieved and gives an outlook on the modelling approach towards accident scenario simulation.
Risk Assessment of Hydrogen Explosion for Private Car with Hydrogen-driven Engine
Sep 2009
Publication
The aim of the study is to identify and quantify the additional risks related to hydrogen explosions during the operation of a hydrogen-driven car. In a first attempt the accidents or failures of a simple one-tank hydrogen storage system have been studied as a main source of risk. Three types of initiators are taken into account: crash accidents fire accidents without crash (no other cars are involved) and hydrogen leakages in normal situation with following ignition. The consequences of hydrogen ignition and/or explosion depend strongly on environmental conditions (geometry wind etc.) therefore the different configurations of operational and environmental conditions are specified.<br/>Then Event Tree/Fault Tree methods are applied for the risk assessment.<br/>The results of quantification permit to draw conclusions about the overall added risk of hydrogen technology as well as about the main contributors to the risk. Results of this work will eventually contribute to the on-going pre-normative research in the field of hydrogen safety.
Determination of Characteristic Parameters for the Thermal Decomposition of Epoxy Resin/carbon Fibre Composites in Cone Calorimeter
Sep 2011
Publication
The thermal degradation of two epoxy resin/carbon fiber composites which differ by their volume fractions in carbon fiber (56 and 59 vol%.) was investigated in cone calorimeter under air atmosphere with a piloted ignition. The external heat flux of cone calorimeter was varied up to 75 kW.m-2 to study the influence of the carbon fiber amount on the thermal decomposition of those composites. Thus main parameters of the thermal decomposition of two different composites were determined such as: mass loss mass loss rate ignition time thermal response parameter ignition temperature critical heat flux thermal inertia and heat of gasification. As a result all the parameters that characterize the thermal resistance of composites are decreased when the carbon fiber volume fraction is increased.
Status of the Pre-normative Research Project PRESLHY for the Safe Use of LH2
Sep 2019
Publication
Liquid hydrogen (LH2) compared to compressed gaseous hydrogen offers advantages for large scale transport and storage of hydrogen with higher densities and potentially better safety performance. Although the gas industry has good experience with LH2 only little experience is available for the new applications of LH2 as an energy carrier. Therefore the European FCH JU funded project PRESLHY conducts pre-normative research for the safe use of cryogenic LH2 in non-industrial settings. The work program consists of a preparatory phase where the state of the art before the project has been summarized and where the experimental planning was adjusted to the outcome of a research priorities workshop. The central part of the project consists of 3 phenomena oriented work packages addressing Release Ignition and Combustion with analytical approaches experiments and simulations. The results shall improve the general understanding of the behavior of LH2 in accidents and thereby enhance the state-of-the-art what will be reflected in appropriate recommendations for development or revision of specific international standards. The paper presents the status of the project at the middle of its terms.
Dynamics of Vented Hydrogen-air Deflagrations
Sep 2011
Publication
The use of hydrogen as an energy carrier is a real perspective for Europe since a number of breakthroughs now enable to envision a deployment at the industrial scale. However some safety issues need to be further addressed but experimental data are still lacking especially about the explosion dynamics in realistic dimensions. A set of hydrogen-air vented explosions were thus performed in two medium scale chambers (1 m3 and 10 m3). Homogeneous mixtures were used (10% to 30% vol.). The explosion overpressure was measured inside the chamber and outside on the axis of the discharge from the vent. The incidence of the external explosion is clearly seen. All the results in this paper and the predictions from the standards differ greatly meaning that a significant effort is still required. It is the purpose of the French project DIMITRHY to help progressing.
European Hydrogen Safety Training Programme for First Responders: Hyresponse Outcomes and Perspectives
Sep 2017
Publication
The paper presents the outcomes of the HyResponse project i.e. the European Hydrogen Safety Training Programme for first responders. The threefold training is described: the content of the educational training is presented the operational training platform and its mock-up real scale transport and hydrogen stationary installations are detailed and the innovative virtual tools and training exercises are highlighted. The paper underlines the outcomes the three pilot sessions as well as the Emergency Response Guide available on the HyResponse’s public website. The next steps for widespread dissemination into the community are discussed.
Validation and Recommendations for CFD and Engineering Modeling of Hydrogen Vented Explosions: Effects of Concentration, Stratification, Obstruction and Vent Area
Oct 2015
Publication
Explosion venting is commonly used in the process industry as a prevention solution to protect equipment or buildings against excessive internal pressure caused by an explosion. This article is dedicated to the validation of FLACS CFD code for the modelling of vented explosions. Analytical engineering models fail when complex cases are considered for instance in the presence of obstacles or H2 stratified mixtures. CFD is an alternative solution but has to be carefully validated. In this study FLACS simulations are compared to published experimental results and recommendations are suggested for their application.
Experiments on the Distribution of Concentration Due to Buoyant Gas Low Flow Rate Release in an Enclosure.
Sep 2009
Publication
Hydrogen energy based vehicles or power generators are expected to come into widespread use in the near future. Safety information is of major importance to support the successful public acceptance of hydrogen as an energy carrier. One of the most important issues in terms of safety is the use of such system in closed area such as a private garage in which a fuel cell car may be parked. This kind of situation leads to the fundamental problem of the dispersion of hydrogen due to a simple vertical source in an enclosure. Many numerical and experimental studies have already been conducted on this problem showing the formation of a stably stratified distribution of concentration. Most of them consider the cases of accidental situation in which the flow rate is relatively important (of the order of 10Nl/min to 100Nl/min). We present a set of experiments conducted on a full scale facility of the size of a typical private garage with helium as a model gas for hydrogen. In this study we focus on the low flow rates that can be characteristic of chronic leaks that may not be detected by security devices of the system (of the order of 0.1Nl/min to 10Nl/min). The facility allows changing natural ventilation conditions and experiments have been conducted from the tightest which is less than 0.01ACH to that typical of a real garage say of the order of 0.1ACH.
Engineering Safety in Hydrogen-Energy Applications
Oct 2015
Publication
Since a few years hydrogen appears as a practical energy vector and some hydrogen applications are already on the market. However these applications are still considered dangerous hazardous events like explosion could occur and some accidents like the Hindenburg disaster are still in the mind. Objectively hydrogen ignites easily and explodes violently. Safety engineering has to be particularly strong and demonstrative; a method of precise identification of accidental scenarios (“probabilities”; “severity”) is developed in this article. This method derived from ARAMIS method permits to identify and to estimate the most relevant safety barriers and therefore helps future users choose appropriate safety strategies.
Cylinders and Tubes Used as Buffers in Filling Stations
Oct 2015
Publication
Buffers are key components for hydrogen filling stations that are currently being developed. Type 1 or composite cylinders are used for this application. The type used depends on many parameters including pressure level cost and space available for the filling station. No international standards exist for such high pressure vessels whereas many standards exist covering Types 123 and 4 used for transport of gas or on-board fuel tanks. It is suggested to use the cylinders approved for transport or on-board applications as buffers. This solution appears to be safe if at least one issue is solved. The main difference is that transport or on-board cylinders are cycled from a low pressure to a high pressure during service whereas buffers are cycled from a relatively high pressure (corresponding to the vehicle’s filling pressure) to the MAWP. Another difference is that buffers are cycled many times per day. For standards developers requesting to systematically verify that buffers pass millions of cycles at low pressure amplitude would be impractical. Several standards and codes give formulae to estimate the number of shallow cycles when number of deep cycles are known. In this paper we describe tests performed on all types of composite cylinders to verify or determine the appropriate formulae.
Vented Hydrogen-air Deflagration in a Small Enclosed Volume
Sep 2013
Publication
Since the rapid development of hydrogen stationary and vehicle fuel cells the last decade it is of importance to improve the prediction of overpressure generated during an accidental explosion which could occur in a confined part of the system. To this end small-scale vented hydrogen–air explosions were performed in a transparent cubic enclosure with a volume of 3375 cm3. The flame propagation was followed with a high speed camera and the overpressure inside the enclosure was recorded using high frequency piezoelectric transmitters. The effects of vent area and ignition location on the amplitude of pressure peaks in the enclosed volume were investigated. Indeed vented deflagration generates several pressures peaks according to the configuration and each peak can be the dominating pressure. The parametric study concerned three ignition locations and five square vent sizes.
Review of Methods For Estimating the Overpressure and Impulse Resulting From a Hydrogen Explosion in a Confined/Obstructed Volume
Sep 2009
Publication
This study deals with the TNO Multi-Energy and Baker-Strehlow-Tang (BST) methods for estimating the positive overpressures and positive impulses resulting from hydrogen-air explosions. With these two methods positive overpressure and positive impulse results depend greatly on the choice of the class number for the TNO Multi-Energy method or the Mach number for the BST methods. These two factors permit the user to read the reduced parameters of the blast wave from the appropriate monographs for each of these methods i.e. positive overpressure and positive duration phase for the TNO Multi-Energy method and positive overpressure and positive impulse for the BST methods. However for the TNO Multi-Energy method the determination of the class number is not objective because it is the user who makes the final decision in choosing the class number whereas with the BST methods the user is strongly guided in their choice of an appropriate Mach number. These differences in the choice of these factors can lead to very different results in terms of positive overpressure and positive impulse. Therefore the objective of this work was to compare the positive overpressures and positive impulses predicted with the TNO Multi-Energy and BST methods with data available from large-scale experiments.
Gaseous Hydrogen Refueling Stations: Selection Of Materials For High Pressure Hydrogen Fueling Connectors
Sep 2005
Publication
Design of hydrogen fueling components is critical for safety and reliability. Intensive usage of such components in urban public environment is expected in the near future. Any leakage of gas or failure of equipment will create potential hazards. Materials for such category of equipment must have specific mechanical characteristics including hardness (influence on the durability of the equipment and on the resistance to hydrogen) and be easy to machine. Air Liquide has developed a test program for qualifying equipment representing the present state of the art. Studies on the susceptibility of various steels to hydrogen embrittlement have been done. Test specimens were exposed to static and cyclic loads with hydrogen and an inert gas the inert gas representing a reference. Various tests are described here. As a result the importance of further development in the design and selection of appropriate materials for critical hydrogen components is required. Various options are presented and discussed.
Explosion and Fire Risk Analyses of Maritime Fuel Cell Rooms with Hydrogen
Sep 2017
Publication
A methodology for explosion and fire risk analyses in enclosed rooms is presented. The objectives of this analysis are to accurately predict the risks associated with hydrogen leaks in maritime applications and to use the approach to provide decision support regarding design and risk-prevention and risk mitigating measures. The methodology uses CFD tools and simpler consequence models for ventilation dispersion and explosion scenarios as well as updated frequency for leaks and ignition. Risk is then efficiently calculated with a Monte Carlo routine capturing the transient behavior of the leak. This makes it possible to efficiently obtain effects of sensitivities and design options maintaining safety and reducing costs.
Unsteady Lumped-Parameter Modelling Of Hydrogen Combustion in The Presence of a Water Spray
Sep 2009
Publication
In case of severe accidents in Pressurized Water Reactors a great amount of hydrogen can be released the resulting heterogeneous gaseous mixture (hydrogen-air-steam) can be flammable or inert and the pressure effects could alter the confinement of the reactor. Water spray systems have been designed in order to reduce overpressures in the containment but the presence of water droplets could enhance flame propagation through turbulence or generate flammable mixtures since the steam present in the vessel could condense on the droplets and could not inert the mixture anymore. However beneficial effects would be heat sinks and homogenization of mixtures. On-going work is devoted to the modelling of the interaction between fine water droplets and a hydrogen-air flame. We present in this paper an unsteady Lumped Parameter model in detail with a special focus on hydrogen-air flame propagation in the presence of water droplets. The effects of the initial concentration of droplets steam and hydrogen concentrations on flame propagation are discussed in the paper and a comparison between this model and our previous steady Lumped-Parameter model highlights the features of the unsteady approach. This physical model can serve as a validation tool for a CFD modelling. The results will be further validated against experimental data.
High-pressure PEM Water Electrolysis and Corresponding Safety Issues
Sep 2009
Publication
In this paper safety considerations related to the operation of proton-exchange membrane (PEM) water electrolysers (hydrogen production capacity up to 1 Nm3/h and operating pressure up to 130 bars) are presented. These results were obtained in the course of the GenHyPEM project a research program on high-pressure PEM water electrolysis supported by the European Commission. Experiments were made using a high-pressure electrolysis stack designed for operation in the 0–130 bars pressure range at temperatures up to 90 °C. Besides hazards related to the pressure itself hydrogen concentration in the oxygen gas production and vice-versa (resulting from membrane crossover permeation effects) have been identified as the most significant risks. Results show that the oxygen concentration in hydrogen at 130 bars can be as high as 2.66 vol %. This is a value still outside the flammability limit for hydrogen–oxygen mixtures (3.9–95.8 vol %) but safety measures are required to prevent explosion hazards. A simple model based on the diffusion of dissolved gases is proposed to account for gas cross-permeation effects. To reduce contamination levels different solutions are proposed. First thicker membranes can be used. Second modified or composite membranes with lower gas permeabilities can be used. Third as reported earlier external catalytic gas recombiners can be used to promote H2/O2 recombination and reduce contamination levels in the gas production. Finally other considerations related to cell and stack design are also discussed to further reduce operation risks.
Safety Cost of a Large Scale Hydrogen System for Photovoltaic Energy Regulation
Sep 2011
Publication
Hydrogen can be used as a buffer for storing intermittent electricity produced by solar plants and/or wind farms. The MYRTE project in Corsica France aims to operate and test a large scale hydrogen facility for regulating the electricity produced by a 560 kWp photovoltaic plant.
Due to the large quantity of hydrogen and oxygen produced and stored (respectively 333 kg and 2654 kg) this installation faces safety issues and safety regulations constraints that can lead to extra costs. These extra costs may concern detectors monitoring barrier equipments that have to be taken into account for evaluating the system‘s total cost.
Relying on the MYRTE example that is an R&D platform the present work consists in listing the whole environmental and safety regulations to be applied in France on both Hydrogen and Oxygen production and storage. A methodology has been developed [1] [2] for evaluating safety extra costs. This methodology takes into account various hydrogen storage technologies (gaseous and solid state) and is applicable to other ways of storage (batteries etc.) to compare them. Results of this work based on a forecast of the operating platform over 20 years can be used to extrapolate and/or optimize future safety costs of next large scale hydrogen systems for further PV or wind energy storage applications.
Due to the large quantity of hydrogen and oxygen produced and stored (respectively 333 kg and 2654 kg) this installation faces safety issues and safety regulations constraints that can lead to extra costs. These extra costs may concern detectors monitoring barrier equipments that have to be taken into account for evaluating the system‘s total cost.
Relying on the MYRTE example that is an R&D platform the present work consists in listing the whole environmental and safety regulations to be applied in France on both Hydrogen and Oxygen production and storage. A methodology has been developed [1] [2] for evaluating safety extra costs. This methodology takes into account various hydrogen storage technologies (gaseous and solid state) and is applicable to other ways of storage (batteries etc.) to compare them. Results of this work based on a forecast of the operating platform over 20 years can be used to extrapolate and/or optimize future safety costs of next large scale hydrogen systems for further PV or wind energy storage applications.
An Experimental Study Dedicated to Wind Influence on Helium Build-up and Concentration Distribution Inside a 1 m 3 Semi-confined Enclosure Considering Hydrogen Energy Applications Conditions of Use
Oct 2015
Publication
Hydrogen energy applications can be used outdoor and thus exposed to environmental varying conditions like wind. In several applications natural ventilation is the first mitigation means studied to limit hydrogen build-up inside a confined area. This study aims at observing and understanding the influence of wind on light gas build-up in addition. Experiments were performed with helium as releasing gas in a 1-m 3 enclosure equipped with ventilation openings varying wind conditions openings location release flow rate; obstructions in front of the openings to limit effects of wind were studied as well. Experimental results were compared together and with the available analytical models.
Safety Strategy for the First Deployment of a Hydrogen- Based Green Public Building in France
Sep 2011
Publication
HELION a subsidiary of AREVA in charge of the business unit Hydrogen and energy storage is deploying for the first time in a French public building a hydrogen-based energy storage system the Greenergy Box™. The 50 kWe system is coupled with a photovoltaic farm to ensure up to 45% electrical autonomy and power backup to the building. The safety system and siting measures of the complete hydrogen chain are described. The paper also highlights the work accomplished with Fire Authorities and Public to gain the acceptance of the project and allow the deployment of four other hydrogen-based green buildings.
Hazard Distance Nomograms for a Blast Wave from a Compressed Hydrogen Tank Rupture in a Fire
Sep 2017
Publication
Nomograms for assessment of hazard distances from a blast wave generated by a catastrophic rupture of stand-alone (stationary) and onboard compressed hydrogen cylinder in a fire are presented. The nomograms are easy to use hydrogen safety engineering tools. They were built using the validated and recently published analytical model. Two types of nomograms were developed – one for use by first responders and another for hydrogen safety engineers. The paper underlines the importance of an international effort to unify harm and damage criteria across different countries as the discrepancies identified by the authors gave the expected results of different hazard distances for different criteria.
Delayed Explosion of Hydrogen High Pressure Jets: An Inter Comparison Benchmark Study
Sep 2017
Publication
Delayed explosions of accidental high pressure hydrogen releases are an important risk scenario for safety studies of production plants transportation pipelines and fuel cell vehicles charging stations. As a consequence the assessment of the associated consequences requires accurate and validated prediction based on modelling and experimental approaches. In the frame of the French working group dedicated to the evaluation of computational fluid dynamics (CFD) codes for the modelling of explosion phenomena this study is dedicated to delayed explosions of high pressure releases. Two participants using two different codes have evaluated the capacity of CFD codes to reproduce explosions of high pressure hydrogen releases. In the first step the jet dispersion is modelled and simulation results are compared with experimental data in terms of axial and radial concentration dilution velocity decay and turbulent characteristics of jets. In the second step a delayed explosion is modelled and compared to experimental data in terms of overpressure at different monitor points. Based on this investigation several recommendations for CFD modelling of high pressure jets explosions are suggested.
Failure of PEM Water Electrolysis Cells: Case Study Involving Anode Dissolution and Membrane Thinning
Sep 2013
Publication
Polymer electrolyte membrane (PEM) water electrolysis is an efficient and environmental friendly method that can be used for the production of molecular hydrogen of electrolytic grade using zero-carbon power sources such as renewable and nuclear. However market applications are asking for cost reduction and performances improvement. This can be achieved by increasing operating current density and lifetime of operation. Concerning performance safety reliability and durability issues the membrane-electrode assembly (MEA) is the weakest cell component. Most performance losses and most accidents occurring during PEM water electrolysis are usually due to the MEA. The purpose of this communication is to report on some specific degradation mechanisms that have been identified as a potential source of performance loss and membrane failure. An accelerated degradation test has been performed on a MEA by applying galvanostatic pulses. Platinum has been used as electrocatalyst at both anode and cathode in order to accelerate degradation rate by maintaining higher cell voltage and higher anodic potential that otherwise would have occurred if conventional Ir/IrOx catalysts had been used. Experimental evidence of degradation mechanisms have been obtained by post-mortem analysis of the MEA using microscopy and chemical analysis. Details of these degradation processes are presented and discussed.
Feasibility of Hydrogen Detection by the Use of Uncoated Silicon Microcantilever-based Sensors
Sep 2013
Publication
Hydrogen is a key parameter to monitor radioactive disposal facility such as the envisioned French geological repository for nuclear wastes. The use of microcantilevers as chemical sensors usually involves a sensitive layer whose purpose is to selectively sorb the analyte of interest. The sorbed substance can then be detected by monitoring either the resonant frequency shift (dynamic mode) or the quasi-static deflection (static mode). The objective of this paper is to demonstrate the feasibility of eliminating the need for the sensitive layer in the dynamic mode thereby increasing the long-term reliability. The microcantilever resonant frequency allows probing the mechanical properties (mass density and viscosity) of the surrounding fluid and thus to determine the concentration of a species in a binary gaseous. Promising preliminary work has allowed detecting concentration of 200 ppm of hydrogen in air with non-optimized geometry of silicon microcantilever with integrated actuation and read-out.
Simulations of Hydrogen Releases from a Storage Tanks- Dispersion and Consequences of Ignition
Sep 2005
Publication
We present results from hydrogen dispersion simulations from a pressurized reservoir at constant flow rate in the presence and absence of a wall. The dispersion simulations are performed using a commercial finite volume solver. Validation of the approach is discussed. Constant concentration envelopes corresponding to the 2% 4% and 15% hydrogen concentration in air are calculated for a subcritical vertical jet and for an equivalent subcritical horizontal jet from a high pressure reservoir. The consequences of ignition and the resulting overpressure are calculated for subcritical horizontal and vertical hydrogen jets and in the latter case compared to available experimental data.
No more items...