Safety
Hydrogen Storage: Recent Improvements and Industrial Perspectives
Sep 2019
Publication
Efficient storage of hydrogen is crucial for the success of hydrogen energy markets (early markets as well as transportation market). Hydrogen can be stored either as a compressed gas a refrigerated liquefied gas a cryo-compressed gas or in hydrides. This paper gives an overview of hydrogen storage technologies and details the specific issues and constraints related to the materials behaviour in hydrogen and conditions representative of hydrogen energy uses. It is indeed essential for the development of applications requiring long-term performance to have good understanding of long-term behaviour of the materials of the storage device and its components under operational loads.
Risk Analysis on Mobile Hydrogen Refueling Stations in the World Expo Shanghai
Sep 2013
Publication
During the World Expo Shanghai there were one hundred fuel-cell sight-seeing cars in operation at the Expo Site. The sight-seeing cars were not allowed to drive out of the Expo Site and the stationary hydrogen refuelling station was not permitted to build at the Expo Site for the sake of safety. A flexible solution to refuel the cars was the application of mobile hydrogen refuelling stations. To better understand the hazards and risks associated with the mobile hydrogen refueling stations a risk analysis was preformed to improve the safety of the operations. The risks to the station personnel and to the public were discussed separately. Results show that the stationary risks of the mobile stations to the personnel and refueling customers are lower than the risk acceptance criteria over an order of magnitude so occupational risks and risks to customers are completely acceptable. The third party risks can be acceptable as long as the appropriate mitigation measures are implemented especially well designed parking area and operation time. Leak from boosters is the main risk contributor to the stationary risks because of its highest failure rates according to the generic data and its worst harm effects based on the consequence evaluations. As for the road risks of the mobile stations they can be acceptable as long as the appropriate mitigation measures are implemented especially well-designed moving path and transportation time.
Numerical Simulation of Homogenous/Inhomogeneous Hydrogen-air Explosion in a Rectangular Channel
Sep 2019
Publication
Hydrogen is one of the promising energy sources in the future because it has the advantages of clean combustion products high efficiency and renewable energy. However hydrogen has the characteristics of low ignition energy wide flammable range (4% -75%) and fast burning flame speed which can cause explosion hazards. Typically the accidental release of hydrogen into confined or semi confined enclosures can often lead to a flammable hydrogen-air mixture with concentration gradients and possible flame acceleration and deflagration-to-detonation transition (DDT). The present study aims to test the capability of our in-house density-based solver ExplosionEngFoam for flame acceleration (FA) and deflagration-to-detonation transition (DDT) in homogenous/inhomogeneous hydrogen-air mixtures. The solver is based on the open source computational fluid dynamics (CFD) platform OpenFOAM and uses the modified Weller et al.’s combustion model taking into account LD and RT instabilities turbulence and non-unity Lewis number etc. Numerical simulations were conducted for both homogeneous and inhomogeneous mixtures in a long enclosed channel with 5.4 m in length and 0.06 m in height. The predictions demonstrate good quantitative agreement with the experimental measurements in flame tip position speed and pressure profiles by Boeck et al. The flow characteristics such as flame fine structure wave evolution etc. were also discussed.
Vapour Cloud Explosions from the Ignition of Methane, Hydrogen, Air Mixtures in a Congested Region
Sep 2007
Publication
To facilitate the transition to the hydrogen economy the EU project NATURALHY is studying the potential for the existing natural gas pipeline networks to transport hydrogen together with natural gas to end-users. Hydrogen may then be extracted for hydrogen fuel-cell applications or the mixture used directly by consumers in existing gas-fired equipment with the benefit of lower carbon emissions. The existing gas pipeline networks are designed constructed and operated to safely transport natural gas mostly methane. However hydrogen has significantly different properties that may adversely affect both the integrity of the network and thereby increase the likelihood of an accidental leak and the consequences if the leak finds a source of ignition. Consequently a major part of the NATURALHY project is focused on assessing how much hydrogen could be introduced into the network without adversely impacting on the safety of the network and the risk to the public. Hydrogen is more reactive than natural gas so the severity of an explosion following an accidental leak may be increased. This paper describes field-scale experiments conducted to measure the overpressures generated by ignition of methane/hydrogen/air mixtures in a congested but unconfined region. Such regions may be found in the gas handling and metering stations of the pipeline networks. The 3 m x 3 m x 2 m high congested region studied contained layers of pipes. The composition of the methane/hydrogen mixture used was varied from 0% hydrogen to 100% hydrogen. On the basis of the experiments performed the maximum overpressures generated by methane/hydrogen mixtures with 25% (by volume) or less hydrogen content are not likely to be much more than those generated by methane alone. Greater percentages of hydrogen did significantly increase the explosion overpressure.
Safe Operation of Natural Gas Appliances Fuelled with Hydrogen & Natural Gas Mixtures (Progress Obtained in the Naturalhy-Project)
Sep 2007
Publication
Considering the transition towards the hydrogen economy dependent on hydrogen penetration scenario the cost of a new hydrogen pipeline infrastructure in Europe may amount to several thousands of billions of EURO’s. Therefore the examination of the potential contribution of the existing natural gas assets is a practical and logical first step. As the physical and chemical properties of hydrogen differ significantly from those of natural gas it is not at all possible to simply exchange natural gas by hydrogen in the existing infrastructure. In this paper first a brief overview will be given of the NATURALHY-project. Further the focus will be on the impact of added hydrogen on the performance of existing natural gas domestic end user appliances which is related to the operation of the natural gas grid connecting the different types of appliance. The application of the fundamental insights and carefully designed experiments comparing the behaviour of gases using justified reference conditions have been shown to offer essential progress. The Wobbe index limits of the natural gas distributed pose a first limiting factor upon the maximum allowable hydrogen concentration. Constant-Wobbe index and decreasing-Wobbe index options of H2 admixture have been studied. Considering the appliance light back H2 limiting factor for domestic appliances fuel-rich appliances are the critical ones. Also taking into account stationary gas engines gas turbines industrial applications and natural gas grid management it is not yet justified to present statements on what level of hydrogen concentration could be safely allowed in which specific natural gas distribution region. But more clarity has been obtained on combustion safety aspects of existing domestic appliances on the connection with Wobbe distribution conditions and on the bottlenecks still to be handled.
Potential for Hydrogen Production from Biomass Residues in the Valencian Community
Sep 2007
Publication
The production of hydrogen from renewable sources is essential to develop the future hydrogen economy. Biomass is an abundant clean and renewable energy source and it can be important in the production of hydrogen. The Valencian Community due to its great agricultural and forestry activities generates an important quantity of biomass residues that can be used for energy generation approximately 778 kt of wet biomass residues per year. This great quantity of biomass can be transformed into a hydrogen-rich gas by different thermochemical conversion processes. In this article the potential of production of hydrogen-rich gas is analyzed considering several factors affecting the conversion yield of these processes. As a result of this analysis it could be possible to produce 1271 MNm3 of H2 per year considering the total biomass residues of the community and selecting the gasification processes.
Hydrogen Subsonic Upward Release and Dispersion Experiments in Closed Cylindrical Vessel
Sep 2007
Publication
Report presents the preliminary experimental results on hydrogen subsonic leakage in a closed vessel under the well-controlled boundary/initial conditions. Formation of hydrogen-air gas mixture cloud was studied for a transient (10 min) upward hydrogen leakage which was followed by subsequent evolution (15 min) of explosive cloud. Low-intensity ( 0.46⋅10−3 m3/sec) hydrogen release was performed via circular (diameter 0.014 m) orifice located in the bottom part of a horizontal cylindrical vessel ( ≈4 m3). A spatially distributed net of the 24 hydrogen sensors and 24 temperature sensors was used to permanently track the time dependence of the hydrogen concentration and temperature fields in vessel. Analysis of the simultaneous experimental records for the different spatial points permits to delineate the basic flow patterns and stages of hydrogen subsonic release in closed vessel in contrast to hydrogen jet release in open environment. The quantitative data were obtained for the averaged speeds of explosive cloud envelop (50% fraction of the Lower Flammability Limit (LFL)) propagation in the vertical and horizontal directions. The obtained data will be used as an experimental basis for development of the guidelines for an indoors allocation of the hydrogen sensors. Data can be also used as a new benchmark case for the reactive Computational Fluid Dynamics codes validation.
On the Use of Spray Systems- An Example of R&D Work in Hydrogen Safety for Nuclear Applications
Sep 2007
Publication
The aim of the present work is to investigate the interaction between a water spray and a laminar hydrogen-air flame in the case of steam inerted mixture. A first work is devoted to study the thermodynamics involved in the phenomena via a lumped parameter code. The flow is two- phase and reactive the gas is multi-component the water spray is polydisperse and the droplet size has certainly an influence on the flame propagation. The energy released by the reaction between hydrogen and oxygen vaporizes suspended droplets. The next step of this study will be to consider a drift-flux model for the droplets and air under hypotheses that the velocity and thermal disequilibria are weak. The multi-component feature of the gas will be further taken into account by studying a gas mixture containing hydrogen air and water vapor. A second study concerns an experimental investigation of the effect of droplets on the flame propagation using a spherical vessel. A Schlieren system is coupled to the spherical vessel in order to record the flame propagation on a digital high speed camera. Both studies will help improve our knowledge of safety relevant phenomena.
Fire Protection Strategy for Compressed Hydrogen-Powered Vehicles
Sep 2007
Publication
Virtually all major automotive companies are currently developing hydrogen-powered vehicles. The vast majority of them employ compressed hydrogen tanks and components as a means of storing the fuel onboard. Compressed hydrogen vehicle fuel systems are designed in the same way as compressed natural gas vehicles (NGV) i.e. the high pressure (up to 70 MPa) fuel is always contained within the system under all conditions with the exception of vehicular fire. In the event of a vehicle fire the fuel system is protected using a non-reclosing thermally activated pressure relief device (PRD) which safely vents the contents. Hydrogen fuel system PRDs are presently qualified to the performance requirements specified in draft hydrogen standards such ANSI/CSA HPRD 1 and EIHP Rev. 12b. They are also qualified with individual fuel tank designs in accordance with the engulfing bonfire requirements in various published/draft tank standards such as CSA B51 Part 2 JARI S001 SAE TIR J2579 ANSI/CSA HGV 2 ISO DIS 15869.2 and EIHP Rev. 12b. Since 2000 there have been over 20 documented NGV tank failures in service 11 of which have been attributed to vehicle fires. This paper will examine whether currently proposed hydrogen performance standards and installation requirements offer suitable fuel system protection in the event of vehicular fires. A number of alternative fire protection strategies will be discussed including:
- The requirement of an engulfing and/or localized fire test for individual tanks fuel systems and complete vehicles;
- The advantages/disadvantages of point source- surface area- and/or fuse-based PRDs
- The use of thermal insulating coatings/blankets for fire protection resulting in the NONventing of the fuel
- The specification of appropriate fuel system installation requirements to mitigate the effect of vehicular fires.
Assessing the Durability and Integrity of Natural Gas Infrastructures for Transporting and Distributing Mixtures of Hydrogen and Natural Gas
Sep 2005
Publication
Extensive infrastructure exists for the transport of natural gas and it is an obvious step to assess its use for the movement of hydrogen. The Naturalhy project’s objective is to prepare the European natural gas industry for the introduction of hydrogen by assessing the capability of the natural gas infrastructure to accept mixtures of hydrogen and natural gas. This paper presents the ongoing work within both Durability and Integrity Work Packages of the Naturalhy project. This work covers a gap in knowledge on risk assessment required for delivering H2+natural gas blends by means of the existing natural gas grids in safe operation.<br/>Experiments involving several parts of the existing infrastructure will be described that are being carried out to re-examine the major risks previously studied for natural gas including: effect of H2 on failure behaviour and corrosion of transmission pipes and their burst resistance (link to the Work Package Safety) on permeability and ageing of distribution pipes on reliability and ageing of domestic gas meters tightness to H2 of domestic appliances and their connexions. The information will be integrated into existing Durability assessment methodologies originally developed for natural gas.<br/>An Integrity Management Tool will be developed taking account of the effect of hydrogen on the materials properties. The tool should enable a cost effective selection of appropriate measures to control the structural integrity and maintaining equipment. The main measures considered are monitoring non destructive examination (pigging and non pigging) and repair strategies. The tool will cover a number of parameters e.g.: percentage of hydrogen in the gas mixture material of construction operating conditions and condition of cathodic protection. Thus the Integrity Management Tool will yield an inspection and maintenance plan based on the specific circumstances.
Molecular Transport Effects of Hydrocarbon Addition on Turbulent Hydrogen Flame Propagation
Sep 2007
Publication
We analytically investigated the influence of light hydrocarbons on turbulent premixed H2/air atmospheric flames under lean conditions in view of safe handling of H2 systems applications in H2 powered IC engines and gas turbines and also with an orientation towards modelling of H2 combustion. For this purpose an algebraic flame surface wrinkling model included with pressure and fuel type effects is used. The model predictions of turbulent premixed flames are compared with the set of corresponding experimental data of Kido et al. (Kido Nakahara et al. 2002). These expanding spherical flame data include H2–air mixtures doped with CH4 and C3H8 while the overall equivalence ratio of all the fuel/air mixtures is fixed at 0.8 for constant unstretched laminar flame speed of 25 cm/s by varying N2 composition. The model predictions show that there is little variation in turbulent flame speed ST for C3H8 additions up to 20-vol%. However for 50 vol% doping flame speed decreases by as much as 30 % from 250 cm/s that of pure H2–air mixtures for turbulence intensity of 200 cm/s. With respect to CH4 for 50 vol% doping ST reduces by only 6 % cf. pure H2/air mixture. In the first instance the substantial decrease of ST with C3H8 addition may be attributed to the increase in the Lewis number of the dual-fuel mixture and proportional restriction of molecular mobility of H2. That is this decrease in flame speed can be explained using the concept of leading edges of the turbulent flame brush (Lipatnikov and Chomiak 2005). As these leading edges have mostly positive curvature (convex to the unburned side) preferential-diffusive-thermal instabilities cause recognizable impact on flame speed at higher levels of turbulence with the effect being very strong for lean H2 mixtures. The lighter hydrocarbon substitutions tend to suppress the leading flame edges and possibly transition to detonation in confined structures and promote flame front stability of lean turbulent premixed flames. Thus there is a necessity to develop a predictive reaction model to quantitatively show the strong influence of molecular transport coefficients on ST.
Computational Modelling of Pressure Effects from Hydrogen Explosions
Sep 2007
Publication
The statement of the problem and algorithm of computational modelling of the processes of formation of the hydrogen-air mixture in the atmosphere its explosion (taking into account chemical interaction) and dispersion of the combustion materials in the open space with complex relief are presented. The finite-difference scheme was developed for the case of the three-dimensional system of gas dynamics equations complemented by the mass conservation laws of the gas admixture and combustion materials. The algorithm of the computation of thermal and physical parameters of the gas mixture appearing as a result of the instantaneous explosion taking into account chemical interaction was developed. The algorithm of computational solution of the difference scheme obtained on the basis of Godunov method was considered. The verification of the mathematical model showed its acceptable accuracy in comparison with known experimental data. It allows using the developed model for the modelling of pressure and thermal consequences of possible failures at the industrial enterprises which store and use hydrogen. The computational modelling of an explosion of the gas hydrogen cloud appearing as a result of instantaneous destruction of high pressure containers at the fuelling station was carried out. The analysis of different ways of protection of the surrounding buildings from destructive effects of the shock wave was conducted. The recommendations considering the choice of dimensions of the protection area around the fuelling station were worked out.
Simulator Development of Virtual Experience and Accident Scenarios of Hydrogen Stations for Safety
Sep 2007
Publication
Nowadays 4 type hydrogen stations have been demonstrated in Korea for preparing hydrogen economy. This simulator is consists of virtual experience modules and virtual accident scenarios of 4 type hydrogen stations. Virtual experience modules show the performance properties through a movie or a virtual reality technology. Also they provide an explanation of hydrogen station equipment and a guide for operators immediately after the accident. Virtual accident scenario modules show accident simulations based on modelling equations as 3D virtual reality. These modules could choose the sham accident for every kind of a station after categorizing all possible accidents in a station A Commercialized CFD program based on hydrogen dispersion model theory shows a movie of accident simulations. The result of a simulator has been developed as web applications. And will be applied to training materials and public relations for a user concerned about hydrogen stations.
Assessment and Evaluation of 3rd Party Risk for Planned Hydrogen Demonstration Facility
Sep 2007
Publication
Potential risk exposure of 3rd parties i.e. people not involved in the actual operation of a plant is often a critical factor to gain authority approval and public acceptance for a development project. This is also highly relevant for development of demonstration facilities for hydrogen production and refuelling infrastructure. This paper presents and discusses results for risk exposure of 3rd parties based on risk assessment studies performed for the planned Hydrogen Technology Research Centre Hytrec in Trondheim. The methodology applied is outlined. Key assumptions and study uncertainties are identified and how these might affect the results are discussed.<br/>The purpose of Hytrec is to build a centre for research development and demonstration of hydrogen as an energy carrier. Hydrogen will be produced both by reforming of natural gas with CO2 capture and by electrolysis of water. The plant also includes a SOFC that will run on natural gas or hydrogen and produce heat and electricity for the Hytrec visitor centre. Hytrec will be located in a populated area without access control. Most of the units will be located within cabinets and modules.<br/>The authors acknowledge the Hytrec project and the Hytrec project partners Statoil Statkraft and DNV for their support and for allowing utilisation of results from the Hytrec QRA in this paper.
Gas Build-up in a Domestic Property Following Releases of Methane/Hydrogen Mixtures
Sep 2007
Publication
The EC funded Naturalhy project is investigating the possibility of promoting the swift introduction of hydrogen as a fuel by mixing hydrogen with natural gas and transporting this mixture by means of the existing natural gas pipeline system to end-users. Hydrogen may then be extracted for use in hydrogen fuel cell applications or the mixture may be used directly in conventional gas-fired equipment. This means that domestic customers would receive a natural gas (methane)/hydrogen mixture delivered to the home. As the characteristics of hydrogen are different from natural gas there may be an increased risk to end-users in the event of an accidental release of gas from internal pipe work or appliances. Consequently part of the Naturalhy project is aimed at assessing the potential implications on the safety of the public which includes end-users in their homes. In order to understand the nature of any gas accumulation which may form and identify the controlling parameters a series of large scale experiments have been performed to study gas accumulations within a 3 m by 3 m by 2.3 m ventilated enclosure representing a domestic room. Gas was released vertically upwards at a pressure typical of that experienced in a domestic environment from hole sizes representative of leaks and breaks in pipe work. The released gas composition was varied and included methane and a range of methane/hydrogen mixtures containing up to 50% hydrogen. During the experiments gas concentrations throughout the enclosure and the external wind conditions were monitored with time. The experimental data is presented. Analysis of the data and predictions using a model developed to interpret the experimental data show that both buoyancy and wind driven ventilation are important.
Hydrogen Related Risks Within a Private Garage: Concentration Measurements in a Realistic Full Scale Experimental Facility
Sep 2007
Publication
Next generation of hydrogen energy based vehicles is expected to come into widespread use in the near future. Various topics related to hydrogen including production storage and application of hydrogen as an energy carrier have become subjects of discussion in the framework of various European and International projects. Safety information is vital to support the successful introduction into mainstream and public acceptance of hydrogen as an energy carrier. One of such issues which is seeking major attention is related to hydrogen powered vehicles parked inside a confined area (such as in a private garage). It is of utmost importance to predict if uncontrolled release of hydrogen from a vehicle parked inside a confined area can create an explosive atmosphere. Subsequently how the preventive measures can be implied to control these explosive atmospheres if present inside a confined area? There is a little guidance currently developed for confined areas accommodating hydrogen fuelled vehicles. It is essential that mitigation measures for such conditions become established.<br/>Characterization of different scenarios those may arise in a real situation from hydrogen fuelled vehicle parked inside a garage and furthermore the investigation of an optimal ventilation rate for hydrogen risk mitigation are some of the main objectives described in the framework of the present study. This work is an effort to provide detail experimental information’s in view of establishing guidelines for hydrogen powered vehicles parked inside a private garage. The present work is developed in the framework of a European Network of Excellence HySafe and French project DRIVE. Present paper describes a purpose built realistic Garage test facility at CEA to study the dispersion of hydrogen leakage. The studied test cases evaluate the influence of injected volumes of hydrogen and the initial conditions at the leakage source on the dispersion and mixing characteristics inside the free volume of the unventilated garage. The mixing process and build-up of hydrogen concentration is measured for the duration of 24 hours. Due to safety reasons helium gas is used to simulate the hydrogen dispersion characteristics.
Hydrogen–methane Mixtures: Dispersion and Stratification Studies
Sep 2011
Publication
The study of hydrogen as an alternative fuel clean and “environment friendly” has been in the last years and continues to be object of many studies international projects and standard development. Hydrogen is a fundamental energy carrier to be developed together with other renewable resources for the transition to a sustainable energy system.<br/>But experience has shown how often the introduction and establishment of a new technology does not necessarily pass through radical changes but can be stimulated by slight modifications to the “present situation”.<br/>So the worldwide experience with natural gas as industrial automotive and domestic fuel has been the incentive to the present interest towards hydrogen–methane mixtures. The possible use of existing pipeline networks for mixtures of natural gas and hydrogen offers a unique and cost-effective opportunity to initiate the progressive introduction of hydrogen as part of the development of a full hydrogen system.<br/>The aim of the work presented in this paper is the investigation of the dispersion and stratification properties of hydrogen and methane mixtures. Experimental activities have been carried out in a large scale closed apparatus characterized by a volume of about 25 m3 both with and without natural ventilation. Mixtures of 10%vol. hydrogen – 90%vol. methane and 30%vol. hydrogen – 70%vol. methane have been studied with the help of oxygen sensors and gas chromatography.
Experimental Releases of Liquid Hydrogen
Sep 2011
Publication
If the hydrogen economy is to progress more hydrogen refuelling stations are required. In the short term in the absence of a hydrogen distribution network the most likely means of supplying the refuelling stations will be by liquid hydrogen road tanker. This development will clearly increase the number of tanker offloading operations significantly and these may need to be performed in more challenging environments with close proximity to the general public. The work described in this paper was commissioned in order to determine the hazards associated with liquid hydrogen spills onto the ground at rates typical for a tanker hose failure during offloading.
Experiments have been performed to investigate spills of liquid hydrogen at a rate of 60 litres per minute. Measurements were made on both unignited and ignited releases.
These include:
Experiments have been performed to investigate spills of liquid hydrogen at a rate of 60 litres per minute. Measurements were made on both unignited and ignited releases.
These include:
- Concentration of hydrogen in air thermal gradient in the concrete substrate liquid pool formation and temperatures within the pool
- Flame velocity within the cloud thermal radiation IR and visible spectrum video records.
- Sound pressure measurements
- An estimation of the extent of the flammable cloud was made from visual observation video IR camera footage and use of a variable position ignition source.
Numerical Studies of Dispersion and Flammable Volume of Hydrogen in Enclosures
Sep 2007
Publication
Hydrogen dispersion in an enclosure is numerically studied using simple analytical solutions and a large-eddy-simulation based CFD code. In simple calculations the interface height and temperature rise of the upper layer are obtained based on mass and energy conservation and the centreline hydrogen volume fraction is derived from similarity solutions of buoyant jets. The calculated centreline hydrogen volume fraction using the two methods agree with each other; however discrepancies are found for the calculated total flammable volume as a result of the inability of simple calculations in taking into account local mixing and diffusion. The CFD model in contrast is found to be capable of correctly reproducing the diffusion and stratification phenomena during the mixing stage.
Hydrogen Safety- New Challenges Based on BMW Hydrogen 7
Sep 2007
Publication
The BMW Hydrogen 7 is the world’s first premium sedan with a bi-fuelled internal combustion engine concept that has undergone the series development process. This car also displays the BMW typical driving pleasure. During development the features of the hydrogen energy source were emphasized. Engine tank system and vehicle electronics were especially developed as integral parts of the vehicle for use with hydrogen. The safety-oriented development process established additional strict hydrogen-specific standards for the Hydrogen 7. The fulfilment of these standards were demonstrated in a comprehensive experimentation and testing program which included all required tests and a large number of additional hydrogen-specific crash tests such as side impacts to the tank coupling system or rear impacts. Furthermore the behaviour of the hydrogen tank was tested under extreme conditions for instance in flames and after strong degradation of the insulation. Testing included over 1.7 million km of driving; and all tests were passed successfully proving the intrinsic safety of the vehicle and also confirming the success of the safety-oriented development process which is to be continued during future vehicle development. A safety concept for future hydrogen vehicles poses new challenges for vehicles and infrastructure. One goal is to develop a car fuelled by hydrogen only while simultaneously optimizing the safety concept. Another important goal is removal of (self-imposed) restrictions for parking in enclosed spaces such as garages. We present a vision of safety standards requirements and a program for fulfilling them.
Study of Hydrogen Diffusion and Deflagration in a Closed System
Sep 2007
Publication
A total of 12 ventilation experiments with various combinations of hydrogen release rates and ventilation speeds were performed in order to study how ventilation speed and release rate effect the hydrogen concentration in a closed system. The experiential facility was constructed out of steel plates and beams in the shape of a rectangular enclosure. The volume of the test facility was about 60m3. The front face of the enclosure was covered by a plastic film in order to allow visible and infrared cameras to capture images of the flame. The inlet and outlet vents were located on the lower front face and the upper backside panel respectively. Hydrogen gas was released toward the ceiling from the center of the floor. The hydrogen gas was released at constant rate in each test. The hydrogen release rate ranged from 0.002 m3/s to 0.02 m3/s. Ventilation speeds were 0.1 0.2 and 0.4 m3/s respectively. Ignition was attempted at the end of the hydrogen release by using multiple continuous spark ignition modules on the ceiling and next to the release point. Time evolution of hydrogen concentration was measured using evacuated sample bottles. Overpressure and impulse inside and outside the facility were also measured. The mixture was ignited by a spark ignition module mounted on the ceiling in eight of eleven tests. In the other three tests the mixture was ignited by spark ignition modules mounted next to the nozzle. Overpressures generated by the hydrogen deflagration in most of these tests were low and represented a small risk to people or property. The primary risk associated with the hydrogen deflagrations studied in these tests was from the fire. The maximum concentration is proportional to the ratio of the hydrogen release rate to the ventilation speed within the range of parameters tested. Therefore a required ventilation speed can be estimated from the assumed hydrogen leak rate within the experimental conditions described in this paper.
Large-scale Hydrogen Release in an Isothermal Confined Area
Sep 2007
Publication
INERIS has set up large-scale fully instrumented experiments to study the formation of flammable clouds resulting from a finite duration spillage of hydrogen in a quiescent room (80 m3 chamber). Concentration temperature and mass flow measurements were monitored during the release period and several hours after. Experiments were carried out for mass flow rates ranging from 02 g/s to 1 g/s. The instrumentation allowed the observation and quantification of rich hydrogen layers stratification effects. This paper presents both the experimental facility and the test results. These experimental results can be used to assess and benchmark CFD tools capabilities.
Quantification of the Uncertainty of the Peak Pressure Value in the Vented Deflagrations of Air-Hydrogen Mixtures
Sep 2007
Publication
In the problem of the protection by the consequences of an explosion is actual for many industrial application involving storage of gas like methane or hydrogen refuelling stations and so on. A simple and economic way to reduce the peak pressure associated to a deflagration is to supply to the confined environment an opportune surface substantially less resistant then the protected structure typically in stoichiometric conditions the peak pressure reduction is around the 8 bars for a generic hydrocarbon combustion in an adiabatic system lacking of whichever mitigation system. In general the problem is the forecast of the peak pressure value (PMAX) of the explosion. This problem is faced using CFD codes modelling the structure in which the explosion is located and setting the main parameters like concentration of the gas in the mixture the volume available the size of vent area and obstacles (if included) and so on. In this work the idea is to start from empirical data to train a Neural Network (NN) in order to find the correlation among the parameters regulating the phenomenon. Associated to this prediction a fuzzy model will provide to quantify the uncertainty of the predicted value.
Safety of Laboratories for New Hydrogen Techniques
Sep 2007
Publication
In this paper a case of hydrogen release in a typical research laboratory for the characterisation of hydrogen solid-state storage materials has been considered. The laboratory is equipped with various testing equipments for the assessment of hydrogen capacity in materials typically in the 1 to 200 bar pressure range and temperatures up to 500°C. Hydrogen is delivered at 200 bar by a 50 l gas bottle and a compressor located outside the laboratory. The safety measures directly related to hydrogen hazard consist in a distributed ventilation of the laboratory and air extraction fume hoods located on top of each instrument. Goal of this work is the modelling of hydrogen accidental release in a real laboratory case in order to provide a more fundamental basis for the laboratory safety design and assist the decision on the number and position of the safety sensors. The computational fluid dynamics code (CFD) ANSYS-CFX has been selected in order to perform the numerical investigations. Two basic accidental release scenarios have been assumed both at 200 bar: a major leak corresponding to a guillotine breaking of the hydrogen distribution line and a smaller leak typical for a not properly tight junction.
The Interaction of Hydrogen Jet Releases With Walls and Barriers
Sep 2009
Publication
It has been suggested that separation or safety distances for pressurised hydrogen storage can be reduced by the inclusion of walls or barriers between the hydrogen storage and vulnerable plant or other items. Various NFPA codes (1) suggest the use of 60° inclined fire barriers for protection against jet flames in preference to vertical ones.<br/>This paper describes a series of experiments performed in order to compare the performance of 60° barriers with that of 90° barriers. Their relative efficiency at protecting from thermal radiation and blast overpressure was measured together with the propensity for the thermal radiation and blast overpressure to be reflected back to the source of the leak. The work was primarily focused on compressed H2 storage for stationary fuel cell systems which may be physically separated from a fuel cell system or could be on board such a system. Different orifice sizes were used to simulate different size leaks and all releases were made were from storage at 200 bar.<br/>Overall conclusions on barrier performance were made based on the recorded measurements.
Materials Considerations in Hydrogen Production
Sep 2007
Publication
Correct selection and application of materials is essential to ensure safety and economy in production transportation and storage of hydrogen. There are several sources of materials challenges related to hydrogen. Established component producers may have limited experience in this specific field. Process developments may involve new process conditions with new demands on the materials. Further new materials will be added to the engineering toolbox to be used. The behaviour of these materials for hydrogen service may need additional documentation. Finally focus on hydrogen susceptibility and hydrogen damages alone may take away awareness of other subjects as trace elements by-products and change in raw materials which may be of as high importance for safety and quality. This overview of challenges and recommendations is made with emphasis on water electrolysis.
Heat Radiation of Burning Hydrogen Air Mixtures Impurified by Organic Vapour and Particles
Sep 2007
Publication
Experiments were performed to investigate the radiative heat emission of small scale hydrogen/air explosions also impurified by minor amounts of inert particles and organic fuels. A volume of 1.5 dm3 hydrogen was injected into ambient air as free-jet and ignited. In further experiments simultaneously inert Aerosil and combustible fuels were injected into the blasting hydrogen/air gas cloud. Fuels were a spray of a solvent (Dipropyleneglycol-methylether) and dispersed particles (milk powder). The combustion was observed with a DV camcorder an IR camera and two different fast scanning spectrometers in NIR and IR range using a sampling rate of 100 spectra/s. The intensity calibrated spectra were analyzed using ICT-BaM code to evaluate emission temperature and intensity of H2O CO2 CO NO and soot emission. Using the same code combined with the experimental results total heat emission of such explosions was estimated.
Predictions of Solid-State Hydrogen Storage System Contamination Processes
Sep 2009
Publication
Solid state materials such as metal and chemical hydrides have been proposed and developed for high energy density automotive hydrogen storage applications. As these materials are implemented into hydrogen storage systems developers must understand their behavior during accident scenarios or contaminated refueling events. An ability to predict thermal and chemical processes during contamination allows for the design of safe and effective hydrogen storage systems along with the development of appropriate codes and standards. A model for the transport of gases within an arbitrary-geometry reactive metal hydride bed (alane -AlH3) is presented in this paper. We have coupled appropriate Knudsen-regime permeability models for flow through packed beds with the fundamental heat transfer and chemical kinetic processes occurring at the particle level. Using experimental measurement to determine and validate model parameters we have developed a robust numerical model that can be utilized to predict processes in arbitrary scaled-up geometries during scenarios such as breach-in-tank or contaminated refueling. Results are presented that indicate the progression of a reaction front through a compacted alane bed as a result of a leaky fitting. The rate of this progression can be limited by; 1) restricting the flow of reactants into the bed through densification and 2) maximizing the rate of heat removal from the bed.
Risk-Informed Separation Distances For Hydrogen Refuelling Stations
Sep 2007
Publication
The development of an infrastructure for the future hydrogen economy will require the simultaneous development of a set of codes and standards. As part of the U.S. Department of Energy Hydrogen Fuel Cells & Infrastructure Technologies Program Sandia National Laboratories is developing the technical basis for assessing the safety of hydrogen-based systems for use in the development/modification of relevant codes and standards. This work includes experimentation and modelling to understand the fluid mechanics and dispersion of hydrogen for different release scenarios including investigations of hydrogen combustion and subsequent heat transfer from hydrogen flames. The resulting technical information is incorporated into engineering models that are used for assessment of different hydrogen release scenarios and for input into quantitative risk assessments (QRA) of hydrogen facilities. The QRAs are used to identify and quantify scenarios for the unintended release of hydrogen and to identify the significant risk contributors at different types of hydrogen facilities. The results of the QRAs are one input into a risk-informed codes and standards development process that can also include other considerations by the code and standard developers. This paper describes an application of QRA methods to help establish one key code requirement: the minimum separation distances between a hydrogen refuelling station and other facilities and the public at large. An example application of the risk-informed approach has been performed to illustrate its utility and to identify key parameters that can influence the resulting selection of separation distances. Important parameters that were identified include the selected consequence measures and risk criteria facility operating parameters (e.g. pressure and volume) and the availability of mitigation features (e.g. automatic leak detection and isolation). The results also indicate the sensitivity of the results to key modelling assumptions and the component leakage rates used in the QRA models.
Predicting the Probability of Failure of Gas Pipelines Including Inspection and Repair Procedures
Sep 2007
Publication
This paper is concerned with predicting the impact on the probability of failure of adding hydrogen to the natural gas distribution network. Hydrogen has been demonstrated to change the behaviour of crack like defects which may affect the safety of pipeline or make it more expensive to operate. A tool has been developed based on a stochastic approach to assess the failure probability of the gas pipeline due to the existence of crack-lie defects including the operational aspects of the pipeline such as inspection and repair procedures. With various parameters such as crack sizes material properties internal pressure modelled as uncertainties a reliability analysis based on failure assessment diagram is performed through direct Monte Carlo simulation. Inspection and repair procedures are included in the simulation to enable realistic pipeline maintenance scenarios to be simulated. In the data preparation process the accuracy of the probabilistic definition of the uncertainties is crucial as the results are very sensitive to certain variables such as the crack depth length and crack growth rate. The failure probabilities of each defect and the whole pipeline system can be obtained during simulation. Different inspection and repair criteria are available in the Monte Carlo simulation whereby an optimal maintenance strategy can be obtained by comparing different combinations of inspection and repair procedures. The simulation provides not only data on the probability of failure but also the predicted number of repairs required over the pipeline life thus providing data suitable for economic models of the pipeline management. This tool can be also used to satisfy certain target reliability requirement. An example is presented comparing a natural gas pipeline with a pipeline containing hydrogen.
Natural and Forced Ventilation Study In An Enclosure Hosting a Fuel Cell
Sep 2009
Publication
The purpose of the experimental work is to determine the conditions for which an enclosure can guest a fuel cell for civil use. Concerning the installation permitting guide this study allows the safe use of the fuel cell in case of small not catastrophic leakages. In fact the correct plan of the vents in the enclosure guarantees the low concentration of hydrogen (H2) below the LFL.
Safety Aspects of Land-Use Planning Scenarios for a Future Infrastructure with Hydrogen Re-Fuelling Stations
Sep 2005
Publication
Hydrogen is currently gaining much attention as a possible future substitute for oil in the transport sector. Hydrogen is not a primary energy source but can be produced from other sources of energy. A future hydrogen economy will need the establishment of new infrastructures for producing storing distributing dispensing and using hydrogen. Hydrogen can be produced in large-scale centralized facilities or in smaller scale on-site systems. Large-scale production requires distribution in pipelines or trucks. A major challenge is to plan the new infrastructures to approach an even safer society regarding safe use of hydrogen. The paper will on the basis of some scenarios for hydrogen deployment highlight and evaluate safety aspects related to future hydrogen economy infrastructures.
Initial Assessment of the Impact of Jet Flame Hazard from Hydrogen Cars in Road Tunnels and the Implication on Hydrogen Car Design
Sep 2007
Publication
Underground or partial underground tunnels form a very important part of modern road transportation systems. As the development of hydrogen cars advancing into the markets it is unavoidable in the near future that hydrogen cars would become the users of ordinary road tunnels. This paper discusses potential fire scenarios and fire hazards of hydrogen cars in road tunnels and implications on the fire safety measures and ventilation systems in existing tunnels. The information needed for carry out risk assessment of hydrogen cars in road tunnels are discussed. hydrogen has a low ignition energy and wide flammable range suggesting that leaks have a high probability of ignition and result hydrogen flame. CFD simulations of hydrogen fires in a full scale 5m by 5m square cross-section tunnel were carried out. The effect of the ventilation on controlling the back-layering and the downstream flame are discussed.
Guidelines for Fire Corps Standard Operating Procedures in the Event of Hydrogen Releases
Sep 2007
Publication
This paper presents a study on the Standard Operating Procedures (P.O.S.s) for the operation of the Fire Corps squads in the event of accidents with a hydrogen release fire or explosion. This study has been carried out by the Italian Working Group on the fire prevention safety issues as one of its main objectives. The Standard Operating Procedures proved to be a basic tool in order to improve the effectiveness of the Fire Corps rescue activity. The unique physical and chemical properties of the hydrogen its use without odorization and its almost invisible flame require a review of the already codified approaches to the rescue operations where conventional gases are involved. However this is only the first step; a Standard Operating Procedure puts together both the theoretical and practical experience achieved on the management of the rescue operations; therefore its arrangement is a cyclic process by nature always under continuous revision updating and improvement.
A Numerical Simulation on the Leakage Event of a High-Pressure Hydrogen Dispenser
Dec 2021
Publication
For the sake of the increasing demand of hydrogen fuel cell vehicles there are more concerns on the safety of hydrogen refueling stations. As one of the key pieces of equipment the hydrogen dispenser has drawn attention on this aspect since it involves massive manual operations and may be bothered by a high probability of failure. In this paper a numerical study is conducted to simulate the possible leakage events of the hydrogen dispenser based on a prototype in China whose working pressure is 70 MPa. The leakage accident is analyzed with respect to leakage sizes leak directions and the time to stop the leakage. It is found that due to the large mass flow rate under such high pressure the leak direction and the layout of the components inside the dispenser become insignificant and the ignitable clouds will form inside the dispenser in less than 1 s if there is a leakage of 1% size of the main tube. The ignitable clouds will form near the vent holes outside the dispenser which may dissipate quickly if the leakage is stopped. On the other hand the gas inside the dispenser will remain ignitable for a long time which asks for a design with no possible ignition source inside. The results can be useful in optimizing the design of the dispenser regarding the reaction time and sensitivity requirements of the leakage detector the size and amount of vent holes etc.
Let’s Go Green With Hydrogen! The General Public’s Perspective
Sep 2011
Publication
It is well known in socio-economics that the success of an innovation process depends to a great extent on public acceptance. The German HyTrust project analyzes the current state of public acceptance in hydrogen technology in the mobility sector. This paper focuses on cutting-edge results of interviews focus groups and a representative survey. Based on these results almost 80% of the Germans are in favor of introducing hydrogen vehicles. But from the perspective of the general public it is important that hydrogen is produced in an environmentally friendly way. HyTrust is the socio-scientific research project that accompanies the German Federal Government's National Innovation Programme.
Simulation of Shock-Initiated Ignition
Sep 2009
Publication
The scenario of detonative ignition in shocked mixture is significant because it is a contributor to deflagration to detonation transition for example following shock reflections. However even in one dimension simulation of ignition between a contact surface or a flame and a shock moving into a combustible mixture is difficult because of the singular nature of the initial conditions. Initially as the shock starts moving into reactive mixture the region filled with reactive mixture has zero thickness. On a fixed grid the number of grid points between the shock and the contact surface increases as the shock moves away from the latter. Due to initial lack of resolution in the region of interest staircasing may occur whereby the resulting plots consist of jumps between few values a few grid points and these numerical artifacts are amplified by the chemistry which is very sensitive to temperature leading to unreliable results. The formulation is transformed replacing time and space by time and space over time as the independent variables. This frame of reference corresponds to the self-similar formulation in which the non-reactive problem remains stationary and the initial conditions are well-resolved. Additionally a solution obtained from short time perturbation is used as initial condition at a time still short enough for the perturbation to be very accurate but long enough so that there is sufficient resolution. The numerical solution to the transformed problem is obtained using an essentially non-oscillatory algorithm which is adequate not only for the early part of the process but also for the latter part when chemistry leads to appearance of a shock and eventually a detonation wave is formed. A validation study was performed and the results were compared with the literature for single step Arrhenius chemistry. The method and its implementation were found to be effective. Results are presented for values of activation energy ranging from mild to stiff.
Health & Safety Laboratory - Gas Detection for Hydrogen Enriched Gas Distribution Networks
Jul 2019
Publication
The UK has committed to significantly reduce greenhouse gas emissions by 2050 to help address climate change. Decarbonising heating is a key part of this and using hydrogen (H2) as a replacement to natural gas (NG) can help in achieving this. The objective of current research including HyDeploy is to demonstrate that NG containing levels of H2 beyond those currently allowed of 0.1 vol% (1000 ppm) [1] can be distributed and utilised safely and efficiently. Initial projects such as HyDeploy are studying the effects of introducing up to 20 vol% H2 in NG but later projects are considering using up to 100 vol% H2.
A key element in the safe operation of a modern gas distribution system is gas detection. However the addition of hydrogen to NG will alter the characteristics of the gas and the impact on gas detection must be considered. It is important that sensors remain sufficiently sensitive to the presence of hydrogen natural gas carbon monoxide (CO) and oxygen (O2) deficiency and that they don’t lead to false positive or false negative readings. The aim of this document is to provide a summary of the requirements for gas detection of hydrogen enriched natural gas for the gas distribution industry and other potentially interested parties. As such it is based on gas detectors presently used by the industry with the only major differences being the effects of hydrogen on the sensitivity of flammable gas sensors and the cross sensitivity of carbon monoxide gas sensors to hydrogen.
There is further information of gas detector concepts and technologies in the appendices.
This report and any attachment is freely available on the ENA Smarter Networks Portal here. IGEM Members can download the report and any attachment directly by clicking on the pdf icon above.
A key element in the safe operation of a modern gas distribution system is gas detection. However the addition of hydrogen to NG will alter the characteristics of the gas and the impact on gas detection must be considered. It is important that sensors remain sufficiently sensitive to the presence of hydrogen natural gas carbon monoxide (CO) and oxygen (O2) deficiency and that they don’t lead to false positive or false negative readings. The aim of this document is to provide a summary of the requirements for gas detection of hydrogen enriched natural gas for the gas distribution industry and other potentially interested parties. As such it is based on gas detectors presently used by the industry with the only major differences being the effects of hydrogen on the sensitivity of flammable gas sensors and the cross sensitivity of carbon monoxide gas sensors to hydrogen.
There is further information of gas detector concepts and technologies in the appendices.
This report and any attachment is freely available on the ENA Smarter Networks Portal here. IGEM Members can download the report and any attachment directly by clicking on the pdf icon above.
Overview of the New Combined Gasoline/Hydrogen Supply Station and Relevant Regulations in Japan
Sep 2007
Publication
When a hydrogen supply station is to be installed in Japan three fundamental laws must be taken into consideration: the High Pressure Gas Safety Law the Building Standards Law and the Fire Service Law. The High Pressure Gas Safety Law in particular regulates procedures for safety concerning hydrogen supply stations. This law came under review accompanying consideration of the potential utilization of fuel cell vehicles and hydrogen stations. At that time the Japan Petroleum Energy Center (JPEC) investigated safety technology for hydrogen supply stations and prepared a draft of the law. Since then a new combined gasoline/hydrogen supply station compliant with the revised law was established on December 2006. There are a large number of safety precautions incorporated into this station model which conform to the law. As a result of these modifications it was possible to reduce the safe setback distance. In this paper we present an overview of the new hydrogen supply station model the safety precautions and the regulations the station is based on.
Simulation of the Fast Filling of Hydrogen Tanks
Sep 2009
Publication
High pressure storage of hydrogen in tanks is a promising option to provide the necessary fuel for transportation purposes. The fill process of a high-pressure tank should be reasonably short but must be designed to avoid too high temperatures in the tank. The shorter the fill should be the higher the maximum temperature in the tank climbs. For safety reasons an upper temperature limit is included in the requirements for refillable hydrogen tanks (ISO 15869) which sets the limit for any fill optimization. It is crucial to understand the phenomena during a tank fill to stay within the safety margins.<br/>The paper describes the fast filling process of hydrogen tanks by simulations based on the Computational Fluid Dynamics (CFD) code CFX. The major result of the simulations is the local temperature distribution in the tank depending on the materials of liner and outer thermal insulation. Different material combinations (type III and IV) are investigated.<br/>Some measurements from literature are available and are used to validate the approach followed in CFX to simulate the fast filling of tanks. Validation has to be continued in future to further improve the predictability of the calculations for arbitrary geometries and material combinations.
High Pressure Hydrogen Jets in the Presence of a Surface
Sep 2009
Publication
The effect of surfaces on the extent of high pressure vertical and horizontal unignited jets is studied using CFD numerical simulations performed with FLACS Hydrogen and Phoenics. For a constant flow rate release of hydrogen from a 284 bar storage unit through a 8.5 mm orifice located 1 meter from the ground the maximum extent of the flammable cloud is determined as a function of time and compared to a free vertical hydrogen jet under identical release conditions. The results are compared to methane numerical simulations and to the predictions of the Birch correlations for the size of the flammable cloud. We find that the maximum extent of the flammable clouds of free jets obtained using CFD numerical simulations for both hydrogen and methane are in agreement with the Birch predictions. For hydrogen horizontal free jets there is strong buoyancy effect observed towards the end of the flammable cloud thus noticeably reducing its centreline extent. For methane horizontal free jets this effect is not observed. For methane the presence of the ground results in a pronounced increase in the extent of the flammable cloud compared to a free jet. The effects of a surface on vertical jets are also studied.
Modeling of Sudden Hydrogen Expansion from Cryogenic Pressure Vessel Failure
Sep 2011
Publication
We have modelled sudden hydrogen expansion from a cryogenic pressure vessel. This model considers real gas equations of state single and two-phase flow and the specific “vessel within vessel” geometry of cryogenic vessels. The model can solve sudden hydrogen expansion for initial pressures up to 1210 bar and for initial temperatures ranging from 27 to 400 K. For practical reasons our study focuses on hydrogen release from 345 bar with temperatures between 62 K and 300 K. The pressure vessel internal volume is 151 L. The results indicate that cryogenic pressure vessels may offer a safety advantage with respect to compressed hydrogen vessels because i) the vacuum jacket protects the pressure vessel from environmental damage ii) hydrogen when released discharges first into an intermediate chamber before reaching the outside environment and iii) working temperature is typically much lower and thus the hydrogen has less energy. Results indicate that key expansion parameters such as pressure rate of energy release and thrust are all considerably lower for a cryogenic vessel within vessel geometry as compared to ambient temperature compressed gas vessels. Future work will focus on taking advantage of these favourable conditions to attempt fail-safe cryogenic vessel designs that do not harm people or property even after catastrophic failure of the inner pressure vessel.
Hydrogen Release from a High-Pressure Gh2 Reservoir in Case of a Small Leak
Sep 2009
Publication
High-pressure GH2 systems are of interest for storage and distribution of hydrogen. The dynamic blow-down process of a high-pressure GH2 reservoir in case of a small leak is a complex process involving a chain of distinct flow regimes and gas states which needs to be understood for safety investigations.<br/>This paper presents models to predict the hydrogen concentration and velocity field in the vicinity of a postulated small leak. An isentropic expansion model with a real gas equation of state for normal hydrogen is used to calculate the time dependent gas state in the reservoir and at the leak position. The subsequent gas expansion to 0.1 MPa is predicted with a zero-dimensional model. The gas conditions after expansion serve as input to a newly developed integral model for a round free turbulent H2-jet into ambient air. The model chain was evaluated by jet experiments with sonic hydrogen releases from different reservoir pressures and temperatures.<br/>Predictions are made for the blow-down of hydrogen reservoirs with 10 30 and 100 MPa initial pressure. The evolution of the pressure in the reservoir and of the H2 mass flux at the orifice are presented in dimensionless form which allows scaling to other system dimensions and initial gas conditions. Computed hydrogen concentrations and masses in the jet are given for the 100 MPa case. A normalized hydrogen concentration field in the free jet is presented which allows for a given leak scenario the prediction of the axial and radial range of burnable H2-air mixtures.
Hydrogen Safety Aspects Related to High Pressure - PEM Water Electrolysis
Sep 2007
Publication
Polymer electrolyte membrane (PEM) water electrolysis has demonstrated its potentialities in terms of cell efficiency (energy consumption ≈ 4.0-4.2 kW/Nm3 H2) and gas purity (> 99.99% H2). Current research activities are aimed at increasing operating pressure up to several hundred bars for direct storage of hydrogen in pressurized vessels. Compared to atmospheric pressure electrolysis high-pressure operation yields additional problems especially with regard to safety considerations. In particular the rate of gases (H2 and O2) cross-permeation across the membrane and their water solubility both increase with pressure. As a result gas purity is affected in both anodic and cathodic circuits and this can lead to the formation of explosive gas mixtures. To prevent such risks two different solutions reported in this communication have been investigated. First the chemical modification of the solid polymer electrolyte in order to reduce cross-permeation phenomena. Second the use of catalytic H2/O2 recombiners to maintain H2 levels in O2 and O2 levels in H2 at values compatible with safety requirements.
A Study of Barrier Walls for Mitigation of Unintended Releases of Hydrogen
Sep 2009
Publication
Hydrogen jet flames resulting from ignition of unintended releases can be extensive in length and pose significant radiation and impingement hazards. Depending on the leak diameter and source pressure the resulting consequence distances can be unacceptably large. One possible mitigation strategy to reduce exposure to jet flames is to incorporate barriers around hydrogen storage and delivery equipment. An experimental and modeling program has been performed at Sandia National Laboratories to better characterize the effectiveness of barrier walls to reduce hazards. This paper describes the experimental and modeling program and presents results obtained for various barrier configurations. The experimental measurements include flame deflection using standard and infrared video and high-speed movies (500 fps) to study initial flame propagation from the ignition source. Measurements of the ignition overpressure wall deflection radiative heat flux and wall and gas temperature were also made at strategic locations. The modeling effort includes three-dimensional calculations of jet flame deflection by the barriers computations of the thermal radiation field around barriers predicted overpressure from ignition and the computation of the concentration field from deflected unignited hydrogen releases. The various barrier designs are evaluated in terms of their mitigation effectiveness for the associated hazards present. The results show that barrier walls are effective at deflecting jet flames in a desired direction and can help attenuate the effects of ignition overpressure and flame radiative heat flux.
Estimation of an Allowable Hydrogen Permeation Rate From Road Vehicle Compressed Gaseous Hydrogen Storage Systems In Typical Garages- Part 3
Sep 2009
Publication
The formation of a flammable hydrogen-air mixture is a major safety concern especially for closed space. This hazardous situation can arise when considering permeation from a car equipped with a composite compressed hydrogen tank with a non-metallic liner in a closed garage. In the following paper a scenario is developed and analysed with a simplified approach and a numerical simulation in order to estimate the evolution of hydrogen concentration. The system is composed of typical size garage and hydrogen car’s tank. Some parameters increasing permeation rate (i.e. tank’s material thickness and pressure) have been chosen to have a conservative approach. A close look on the top of tank surface showed that the concentration grows as square root of time and does not exceed 8.2×10-3 % by volume. Also a simplified comparative analysis estimated that the buoyancy of hydrogen-air mixture prevails on the diffusion 35 seconds after permeation starts in good agreement with simulation where time is at about 80 seconds. Finally the numerical simulations demonstrated that across the garage height the hydrogen is nearly distributed linearly and the difference in hydrogen concentration at the ceiling and floor is negligible (i.e. 3×10-3 %).
For a Successful Arrival of the Hydrogen Economy Improve Now the Confidence Level of Risk Assessments
Sep 2009
Publication
For large-scale distribution and use of energy carriers classified as hazardous material in many countries as a method to assist land use planning to grant licenses to design a safe installation and to operate it safely some form of risk analysis and assessment is applied. Despite many years of experience the methods have still their weaknesses even the most elaborated ones as e.g. shown by the large spread in results when different teams perform an analysis on a same plant as was done in EU projects. Because a fuel as hydrogen with its different properties will come new in the daily use of many people incidents may happen and risks will be discussed. HySafe and other groups take good preparatory action in this respect and work in the right direction as appears from various documents produced. However already a superficial examination of the results so far tells that further cooperative work is indispensable. To avoid criticism skepticism and frustration not only the positive findings should be described and general features of the methods but the community has also to give strong guidance with regard to the uncertainties. Scenario development appears to be very dependent on insight and experience of an individual analyst leak and ignition probability may vary over a wide range of values Computational Fluid Dynamics or CFD models may lead to very different result. The Standard Benchmark Exercise Problems SBEPs are a good start but shall produce guidelines or recommendations for CFD use or even perhaps certification of models. Where feasible narrowing of possible details of scenarios to the more probable ones taking into account historical incident data and schematizing in bowties more explicit use of confidence intervals on e.g. failure rates and ignition probability estimates will help. Further knowledge gaps should be defined.
Simulation of Detonation after an Accidental Hydrogen Release in Enclosed Environments
Sep 2007
Publication
An accidental hydrogen release in equipment enclosures may result in the presence of a detonable mixture in a confined environment. Numerical simulation is potentially a useful tool for damage assessment in these situations. To assess the value of CFD techniques numerical simulation of detonation was performed for two realistic scenarios. The first scenario starts with a pipe failure in an electrolyzer resulting in a leak of 42 g of hydrogen. The second scenario deals with a failure in a reformer where 84 g of hydrogen is released. In both cases dispersion patterns were first obtained from separate numerical simulation and were then used as initial condition in a detonation simulation based upon the reactive Euler's equations. Energy was artificially added in a narrow region to simulate detonative ignition. In the electrolyzer ignition was assumed to occur 500 ms after beginning of the release. Results show a detonation failing on the top and bottom side but propagating left and right before eventually failing also. Average impulse was 500 Ns/m². For the reformer three cases were simulated with ignition 1.0 1.4 and 2.0 seconds after the beginning of the release. In two cases the detonation wave failed everywhere except in the direction of the release in which it continued propagating until reaching the side wall. In the third the detonation failed everywhere at first but later a deflagration to detonation transition occurred resulting in a strong wave that propagated rapidly toward the side wall. In all three cases the consequences are more serious than in the electrolyzer.
Numerical Simulation of The Laminar Hydrogen Flame In The Presence of a Quenching Mesh
Sep 2009
Publication
Recent studies of J.H. Song et al. and S.Y. Yang et al. have been concentrated on mitigation measures against hydrogen risk. The authors have proposed installation of quenching meshes between compartments or around the essential equipment in order to contain hydrogen flames. Preliminary tests were conducted which demonstrated the possibility of flame extinction using metallic meshes of specific size.<br/>Considerable amount of numerical and theoretical work on flame quenching phenomenon has been performed in the second half of the last century and several techniques and models have been proposed to predict the quenching phenomenon of the laminar flame system. Most of these models appreciated the importance of heat loss to the surroundings as a primary cause of extinguishment in particular the heat transfer by conduction to the containing wall. The supporting simulations predict flame-quenching structure either between parallel plates (quenching distance) or inside a tube of a certain diameter (quenching diameter).<br/>In the present study the flame quenching is investigated assuming the laminar hydrogen flame propagating towards a quenching mesh using two-dimensional configuration and the earlier developed models. It is shown that due to a heat loss to a metallic grid the flame can be quenched numerically.
Allowable Hydrogen Permeation Rate From Road Vehicle Compressed Gaseous Storage Systems In Garages- Part 1- Introduction, Scenarios, and Estimation of an Allowable Permeation Rate
Sep 2009
Publication
The paper presents an overview of the main results of the EC NOE HySafe activity to estimate an allowable hydrogen permeation rate for automotive legal requirements and standards. The work was undertaken as part of the HySafe internal project InsHyde.<br/>A slow long term hydrogen release such as that due to permeation from a vehicle into an inadequately ventilated enclosed structure is a potential risk associated with the use of hydrogen in automotive applications. Due to its small molecular size hydrogen permeates through the containment materials found in compressed gaseous hydrogen storage systems and is an issue that requires consideration for containers with non-metallic (polymer) liners. Permeation from compressed gaseous hydrogen storage systems is a current hydrogen safety topic relevant to regulatory and standardisation activities at both global and regional levels.<br/>Various rates have been proposed in different draft legal requirements and standards based on different scenarios and the assumption that hydrogen dispenses homogeneously. This paper focuses on the development of a methodology by HySafe Partners (CEA NCSRD. University of Ulster and Volvo Technology) to estimate an allowable upper limit for hydrogen permeation in automotive applications by investigating the behaviour of hydrogen when released at small rates with a focus on European scenario. The background to the activity is explained. reasonable scenarios are identified a methodology proposed and a maximum hydrogen permeation rate from road vehicles into enclosed structures is estimated The work is based on conclusions from the experimental and numerical investigations described by CEA NCSRD and the University of Ulster in related papers.