Safety
3D Real Time Monitoring of H2 in FCV Applications
Sep 2019
Publication
In order to monitor a trace amount of Hydrogen in millisecond portable H2 sensor (Sx) was made by using mass spectrometer. The method of monitoring the hydrogen pulse of millisecond in exhaust gas is the increasing needed. Determining H2 concentration both inside and outside of the Fuel Cell Vehicle (FCV) for the optimized operations is becoming a critical issue. The exhaust gas of Fuel Cell Vehicle H2 consumption flushing and disposal around Fuel cell the real time monitoring of H2 in highly humid conditions is the problematic. To solve this issue the system volume of the sampling route was minimized with the heater and the dehumidifier to avoid condensation of water droplets. And also for an automatic calibration of H2 concentration the small cylinder of specific H2 concentration was mounted into the system.<br/>Our basic experiment started from a flow pattern analysis by monitoring H2 concentration in narrow tube. The flow patter analysis was carried out. When H2 gas was introduced in the N2 flow or air in the tube the highly concentrated H2 front phases were observed. This H2 sensor can provide the real time information of the hydrogen molecules and the clouds. The basic characterization of this sensor showed 0-100% H2 concentrations within milliseconds. Our observations showed the size of the high concentration phase of H2 and the low concentration phase after mixing process. The mixed and unmixed H2 unintended concentration of H2 cloud the high speed small cluster of H2 molecules in purged gas were explored by this system.
Performance Evaluation of Empirical Models for Vented Lean Hydrogen Explosions
Sep 2017
Publication
Explosion venting is a method commonly used to prevent or minimize damage to an enclosure caused by an accidental explosion. An estimate of the maximum overpressure generated though explosion is an important parameter in the design of the vents. Various engineering models (Bauwens et al. 2012 Molkov and Bragin 2015) and European (EN 14994 ) and USA standards (NFPA 68) are available to predict such overpressure. In this study their performance is evaluated using a number of published experiments. Comparison of pressure predictions from various models have also been carried out for the recent experiments conducted by GexCon using a 20 feet ISO container. The results show that the model of Bauwens et al. (2012) predicts well for hydrogen concentration between 16% and 21% and in the presence of obstacles. The model of Molkov et al. (2015) is found to work well for hydrogen concentrations between 10% and 30% without obstacles. In the presence of obstacles as no guidelines are given to set the coefficient for obstacles in the model it was necessary to tune the coefficient to match the experimental data. The predictions of the formulas in NFPA 68 show a large scatter across different tests. The current version of both EN 14994 and NFPA 68 are found to have very limited range of applicability and can hardly be used for vent sizing of hydrogen-air deflagrations. Overall the accuracy of all the engineering models was found to be limited. Some recommendations concerning their applicability will be given for vented lean-hydrogen explosion concentrations of interest to practical applications.
Hydrogen Wide Area Monitoring of LH2 Releases at HSE for the PRESLHY Project
Sep 2021
Publication
The characterization of liquid hydrogen (LH2) releases has been identified as an international research priority to facilitate the safe use of hydrogen as an energy carrier. Empirical field measurements such as those afforded by Hydrogen Wide Area Monitoring can elucidate the behavior of LH2 releases which can then be used to support and validate dispersion models. Hydrogen Wide Area Monitoring can be defined as the quantitative three-dimensional spatial and temporal profiling of planned or unintentional hydrogen releases. The NREL Sensor Laboratory developed a Hydrogen Wide Area Monitor (HyWAM) based upon a distributed array of hydrogen sensors. The NREL Sensor Laboratory and the Health and Safety Executive (HSE) formally committed to collaborate on profiling GH2 and LH2 releases which allowed for the integration of the NREL HyWAM into the HSE LH2 release behavior investigation supported by the FCH JU Prenormative Research for the Safe Use of Liquid Hydrogen (PRESLHY) program. A HyWAM system was deployed consisting of 32 hydrogen measurement points and co-located temperature sensors distributed downstream of the LH2 release apparatus developed by HSE. In addition the HyWAM deployment was supported by proximal wind and weather monitors. In a separate presentation at this conference “HSE Experimental Summary for the Characterisation Dispersion and Electrostatic Hazards of LH2 for the PRESLHY Project” HSE researchers summarize the experimental apparatus and protocols utilized in the HSE LH2 releases that were performed under the auspices of PRESLHY. As a supplement to the HSE presentation this presentation will focus on the spatial and temporal behavior LH2 releases as measured by the NREL HyWAM. Correlations to ambient conditions such as wind speed and direction plume temperature and hydrogen concentrations will be discussed in addition to the design and performance of the NREL HyWAM and its potential for improving hydrogen facility safety.
Experimental Study and Model Predictions on Helium Release in an Enclosure with Single or Multiple Vents
Sep 2021
Publication
This paper presents experiments performed at Canadian Nuclear Laboratories (CNL) to examine the dispersion behaviour of helium in a polycarbonate enclosure that was representative of a residential parking garage. The purpose was to gain a better understanding of the effect of buoyancy- or winddriven natural ventilation on hydrogen dispersion behaviour. Although hydrogen dispersion studies have been reported extensively in the literature gaps still exist in predictive methods for hazard analysis. Helium a simulant for hydrogen was injected near the centre of the floor with a flow rate ranging from 5 to 75 standard litres per minute through an upward-facing nozzle resulting in an injection Richardson number ranging between 10-1 and 102. The location of the nozzle varied from the bottom of the enclosure to near the ceiling to examine the impact of the nozzle elevation on the development of a stratified layer in the upper region of the enclosure. When the injection nozzle was placed at a sufficiently low elevation the vertical helium profile always consisted of a homogenous layer at the top overlaying a stratified layer at the bottom. To simulate outdoor environmental conditions a fan was placed in front of each vent to examine the effect of opposing or assisting wind on the dispersion. The helium transients in the uniform layer predicted with analytical models were in good agreement with the measured transients for the tests with injection at lower elevations or with no wind. Model improvements are required for adequately predicting transients with significantly stratified profiles or with wind.
Experimental Investigations Relevant for Hydrogen and Fission Product Issues Raised by the Fukushima Accident
Jan 2015
Publication
The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011 caused by an earthquake and a subsequent tsunami resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation leakage from primary containment boundary to the reactor building improper functioning of standby gas treatment system (SGTS) unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous aqueous and solid materials available for interaction e.g. gas components decontamination paint aerosols and water pools. In the light of the Fukushima accident additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally as more and more passive safety systems such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics hydrogen aerosols and iodine) test facility (9.2 m high 3.2 m in diameter and 60 m3 volume) are discussed in the light of the Fukushima accident.
Effects of the Injector Direction on the Temperature Distribution During Filling of Hydrogen Tanks
Sep 2017
Publication
The development of the temperature field in hydrogen tanks during the filling process has been investigated with Computational Fluid Dynamics (CFD). Measurements from experiments undertaken at the JRC GasTef facility have been used to develop and validate the CFD modelling strategy; by means of the CFD calculations the effect of the injector direction on the temperature distribution has been analysed. It has been found that the dynamics of the temperature field including the development of potentially detrimental phenomena like thermal stratification and temperature inhomogeneity e.g. hot spots can be significantly affected by the injector orientation.
Development of a Realistic Hydrogen Flammable Atmosphere Inside a 4-m3 Enclosure
Sep 2017
Publication
To define a strategy of mitigation for containerized hydrogen systems (fuel cells for example) against explosion the main characteristics of flammable atmosphere (size concentration turbulence…) shall be well-known. This article presents an experimental study on accidental hydrogen releases and dispersion into an enclosure of 4 m3 (2 m x 2 m x 1 m). Different release points are studied: two circular releases of 1 and 3 mm and a system to create ring-shaped releases. The releases are operated with a pressure between 10 and 40 bars in order to be close to the process conditions. Different positions of the release inside the enclosure i.e. centred on the floor or along a wall are also studied. A specific effort is made to characterize the turbulence in the enclosure during the releases. The objectives of the experimental study are to understand and quantify the mechanisms of formation of the explosive atmosphere taking into account the geometry and position of the release point and the confinement. Those experimental data are analyzed and compared with existing models and could bring some new elements to improve them.
Model of 3D Conjugate Heat Transfer and Mechanism of Compressed Gas Storage Failure in a Fire
Sep 2017
Publication
The 3D model of conjugate heat transfer from a fire to compressed gas storage cylinder is described. The model predictions of temperature outside and inside the cylinder as well as pressure increase during a fire are compared against a fire test experiment. The simulation reproduced measured in test temperatures and pressures. The original failure criterion of the cylinder in a fire has been applied in the model. This allowed for the prediction of the cylinder catastrophic rupture time with acceptable engineering accuracy. The significance of 3D modelling is demonstrated and recommendations to improve safety of high-pressure composite tanks are given.
Fire Tests Carried Out in FCH JU FIRECOMP Project, Recommendations and Application to Safety of Gas Storage Systems
Sep 2017
Publication
In the event of a fire composite pressure vessels behave very differently from metallic ones: the material is degraded potentially leading to a burst without significant pressure increase. Hence such objects are when necessary protected from fire by using thermally-activated devices (TPRD) and standards require testing cylinder and TPRD together. The pre-normative research project FireComp aimed at understanding better the conditions which may lead to burst through testing and simulation and proposed an alternative way of assessing the fire performance of composite cylinders. This approach is currently used by Air Liquide for the safety of composite bundles carrying large amounts of hydrogen gas.
A Comparison Study into Low Leak Rate Buoyant Gas Dispersion in a Small Fuel Cell Enclosure Using Plain and Louvre Vent Passive Ventilation Schemes
Sep 2017
Publication
The development of a ‘Hydrogen Economy’ will see hydrogen fuel cells used in transportation and the generation of power for buildings as part of a decentralised grid with low power units used in domestic and commercial environmental situations. Low power fuel cells will be housed in small protective enclosures which must be ventilated to prevent a build-up of hydrogen gas produced during normal fuel cell operation or a supply pipework leak. Hydrogen’s flammable range (4-75%) is a significant safety concern. With poor enclosure ventilation a low-level leak (below 10 lpm) could quickly create a flammable mixture with potential for an explosion. Mechanical ventilation is effective at managing enclosure hydrogen concentrations but drains fuel cell power and is vulnerable to failure. In many applications (e.g. low power and remote installation) this is undesirable and reliable passive ventilation systems are preferred. Passive ventilation depends upon buoyancy driven flow with the size and shape of ventilation openings critical for producing predictable flows and maintaining low buoyant gas concentrations. Environmentally installed units use louvre vents to protect the fuel cell but the performance of these vents compared to plain vertical vents is not clear. Comparison small enclosure tests of ‘same opening area’ louvre and plain vents with leak rates from 1 to 10 lpm were conducted. A displacement ventilation arrangement was installed on the test enclosure with upper and lower opposing openings. Helium gas was released from a 4mm nozzle at the base of the enclosure to simulate a hydrogen leak. The tests determined that louvre vents increased average enclosure hydrogen concentrations by approximately 10% across the leak range tested but regulated the flow. The test data was used in a SolidWorks CFD simulation model validation exercise. The model provided a good qualitative representation of the flow behaviour but under predicted average concentrations.
Analysis of Out-of-spec Events During Refueling of On-board Hydrogen Tanks
Sep 2017
Publication
For refuelling on-board hydrogen tanks table-based or formula based protocols are commonly used. These protocols are designed to achieve a tank filling close to 100% SOC (State of Charge) in s safe way: without surpassing temperature (-40°C to 85°C) and pressure limits (125% Nominal Working Pressure NWP). The ambient temperature the initial pressure and the volume category of the (compressed hydrogen storage system CHSS are used as inputs to determine the final target pressure and the pressure ramp rate (which controls the filling duration). However abnormal out-of-spec events (e.g. misinformation of storage system status and characteristics of the storage tanks) may occur and result in a refuelling in which the safety boundaries are surpassed. In the present article the possible out of specification (out-of-spec) events in a refuelling station have been analyzed. The associated hazards when refuelling on-board hydrogen tanks have been studied. Experimental results of out-of-spec event tests performed on a type 3 tank are presented. The results show that on the type 3 tank the safety temperature limit of 85°C was only surpassed under a combination of events; e.g. an unnoticed stop of the cooling of the gas combined with a wrong input of ambient temperature at a very warm environment. On the other hand under certain events (e.g. cooling the gas below the target temperature) and in particular under cold environmental conditions the 100% SOC limit established in the fuelling protocols has been surpassed. Hydrogen safety on-board tanks refuelling protocols out-of-spec events.
Health and safety in the new energy economy
Dec 2010
Publication
Over the next decade and beyond the UK is set to take significant steps towards a new energy economy. This will be an economy where the technologies meeting<br/>our electricity heat and fuel needs have to deliver against three key criteria: sustainability security and affordability.<br/><br/>In this context a wide range of emerging energy technologies are expected to play an important role in reshaping the way we satisfy our energy requirements. The extent to which they do so however will depend fundamentally on their ability to be harnessed safely.<br/><br/>Compiled by HSE’s Emerging Energy Technologies Programme this report provides a current assessment of the health and safety hazards that key emerging energy technologies could pose both to workers and to the public at large. (Nuclear energy technologies fall outside the scope of this report.) But it also highlights how an appropriate framework can be and is being put in place to help ensure that these hazards are managed and controlled effectively – an essential<br/>element in enabling the technologies to make a major contribution to the UK’s energy future.
A Comparative CFD Assessment Study of Cryogenic Hydrogen and Liquid Natural Gas Dispersion
Sep 2017
Publication
The introduction of hydrogen to the commercial market as alternative fuel brings up safety concerns. Its storage in liquid or cryo-compressed state to achieve volumetric efficiency involves additional risks and their study is crucial. This work aims to investigate the behaviour of cryogenic hydrogen release and to study factors that affect the vapor dispersion. We focus on the effect of ambient humidity and air's components (nitrogen and oxygen) freezing in order to identify the conditions under which these factors have considerable influence. The study reveals that the level of influence depends highly on the release conditions and that humidity can reduce conspicuously the longitudinal distance of the Lower Flammability Limit (LFL). Low Froude (Fr) number (<1000) at the release allows the generated by the humidity phase change buoyancy to affect the dispersion while for higher Fr number - that usually are met in cryo-compressed releases - the momentum forces are the dominant forces and the buoyancy effect is trivial. Simulations with liquid methane release have been also performed and compared to the liquid hydrogen simulations in order to detect the differences in the behaviour of the two fuels as far as the humidity effect is concerned. It is shown that in methane spills the buoyancy effect in presence of humidity is smaller than in hydrogen spills and it can be considered almost negligible.
Highly Resolve Large Eddy Simulations of a Transitional Air-helium Buoyant Jet in a Two Vented Enclosure: Validation Against Particle Image Velocimetry Experiments
Sep 2017
Publication
The article deals with LES simulations of an air-helium buoyant jet in a two vented enclosure and their validation against particle image velocimetry experiments. The main objective is to test the ability of LES models to simulate such scenarios. These types of scenarios are of first interest considering safety studies for new hydrogen systems. Three main challenges are identified. The two first are the ability of the LES model to account for a rapid laminar-to-turbulence transition mainly due to the buoyancy accelerations and the Rayleigh-Taylor instabilities that can develop due to sharp density gradients. The third one is the outlet boundary conditions to be imposed on the vent surfaces. The influence of the classical pressure boundary condition is studied by comparing the simulations results when an exterior region is added in the simulations. The comparisons against particle image velocimetry experiments show that the use of an exterior domain gives more accurate results than the classical pressure boundary condition. This result and the description of the phenomena involved are the main outlets of the article.
Spontaneous Ignition of Hydrogen- Literature Review
Jan 2008
Publication
Objectives
The aim of this review is to establish which available literature may be of use as part of the HSE funded project which will investigate spontaneous ignition of accidental hydrogen releases (JR02071). It will identify phenomena that have the potential to cause spontaneous ignition of releases of pressured hydrogen and identify literature that may be of use when formulating the experimental program.
Main Findings
The identification of important work that shows conclusive evidence of spontaneous ignition of hydrogen due to the failure of a boundary layer.
The aim of this review is to establish which available literature may be of use as part of the HSE funded project which will investigate spontaneous ignition of accidental hydrogen releases (JR02071). It will identify phenomena that have the potential to cause spontaneous ignition of releases of pressured hydrogen and identify literature that may be of use when formulating the experimental program.
Main Findings
The identification of important work that shows conclusive evidence of spontaneous ignition of hydrogen due to the failure of a boundary layer.
A Study on the Effectivity of Hydrogen Leakage Detection for Hydrogen Fuel Cell
Sep 2017
Publication
Unlike four-wheel fuel-cell vehicles fuel-cell motorcycles have little semi-closure space corresponding to the engine compartment of four-wheel fuel-cell vehicles. Furthermore motorcycles may fall while parked or running. We conducted hydrogen concentration measurement and ignition tests to evaluate the feasibility of detecting leaks when hydrogen gas leaked from a fuel-cell motorcycle as well as the risk of ignition. We found that the installation of hydrogen leak detectors is effective because it is possible to detect minute hydrogen leaks by installing leak detectors at appropriate points on the fuel cell motorcycle and risks can be reduced by interrupting the hydrogen leak immediately after detection.
Experimental Measurements, CFD Simulations and Model for a Helium Release in a Two Vents Enclosure
Sep 2017
Publication
The present work proposes improvements on a model developed by Linden to predict the concentration distribution in a 2 vented cavities. Recent developments on non constant entrainment coefficient from Carazzo et al as well as a non constant pressure distribution at the vents-the vents being vertical-are included in the Linden approach. This model is compared with experimental results from a parametric study on the influence of the height of the release source on the helium dispersion regimes inside a naturally ventilated 2 vents enclosure. The varying parameters of the study were mainly the height of the release the releasing flow rate and the geometry of the vents. At last Large Eddy Simulations of the flow and Particle Image Velocimetry measurements performed on a small 2 vented cavity are presented. The objective is to have a better understanding of the flow structure which is at the origin of the 2 layers concentration distribution described by Linden.
Hazards of Liquid Hydrogen: Position paper
Jan 2010
Publication
In the long term the key to the development of a hydrogen economy is a full infrastructure to support it which include means for the delivery and storage of hydrogen at the point of use eg at hydrogen refuelling stations for vehicles. As an interim measure to allow the development of refuelling stations and rapid implementation of hydrogen distribution to them liquid hydrogen is considered the most efficient and cost effective means for transport and storage.
The Health and Safety Executive have commissioned the Health and Safety Laboratory to identify and address issues relating to bulk liquid hydrogen transport and storage and update/develop guidance for such facilities. This position paper the first part of the project assesses the features of the transport and storage aspects of the refuelling stations that are now being constructed in the UK compares them to existing guidance highlights gaps in the regulatory regime and identifies outstanding safety issues. The findings together with the results of experiments to improve our understanding of the behaviour of liquid hydrogen will inform the development of the guidance for refuelling facilities
link to Report
The Health and Safety Executive have commissioned the Health and Safety Laboratory to identify and address issues relating to bulk liquid hydrogen transport and storage and update/develop guidance for such facilities. This position paper the first part of the project assesses the features of the transport and storage aspects of the refuelling stations that are now being constructed in the UK compares them to existing guidance highlights gaps in the regulatory regime and identifies outstanding safety issues. The findings together with the results of experiments to improve our understanding of the behaviour of liquid hydrogen will inform the development of the guidance for refuelling facilities
link to Report
Loss of Integrity of Hydrogen Technologies: A Critical Review
Jul 2020
Publication
Hydrogen is one of the main candidates in replacing fossil fuels in the forthcoming years. However hydrogen technologies must deal with safety aspects due to the specific substance properties. This study aims to provide an overview on the loss of integrity (LOI) of hydrogen equipment which may lead to serious consequences such as fires and explosions. Substantial information regarding the hydrogen lifecycle its properties and safety related aspects has gathered. Furthermore focus has placed on the phenomena responsible for the LOI (e.g. hydrogen embrittlement) and material selection for hydrogen services. Moreover a systematic review on the hydrogen LOI topic has conducted to identify and connect the most relevant and active research group within the topic. In conclusion a significant dearth of knowledge in material behaviour of hydrogen technologies has highlighted. It is thought that is possible to bridge this gap by strengthening the collaborations between scientists from different research fields.
Hydrogen Jet Structure in Presence of Forced Co-, Counter- and Cross-flow Ventilation
Sep 2021
Publication
This paper presents results of experimental investigations on unignited horizontal hydrogen jets in air in presence of co- cross- and counter-flow. Hydrogen concentration distributions are obtained as functions of distance to the hydrogen release nozzle. The H2-jet variables are two nozzle diameters 1 mm and 4 mm and two H2-jet mass flow rates 1 g/s up to 5 g/s. A propeller fan is used to provide forced ventilation compared to the case with no ventilation three different airflow velocities up to 5 m/s were studied systematically. It was found that any forced ventilation in co- cross- and counter-flow direction reduces the size of the burnable mixture cloud of the H2-jet compared to a free jet in quiescent air.
Analysis of Hydrogen-Induced Changes in the Cyclic Deformation Behaviour of AISI 300–Series Austenitic Stainless Steels Using Cyclic Indentation Testing
Jun 2021
Publication
The locally occurring mechanisms of hydrogen embrittlement significantly influence the fatigue behaviour of a material which was shown in previous research on two different AISI 300-series austenitic stainless steels with different austenite stabilities. In this preliminary work an enhanced fatigue crack growth as well as changes in crack initiation sites and morphology caused by hydrogen were observed. To further analyze the results obtained in this previous research in the present work the local cyclic deformation behaviour of the material volume was analyzed by using cyclic indentation testing. Moreover these results were correlated to the local dislocation structures obtained with transmission electron microscopy (TEM) in the vicinity of fatigue cracks. The cyclic indentation tests show a decreased cyclic hardening potential as well as an increased dislocation mobility for the conditions precharged with hydrogen which correlates to the TEM analysis revealing courser dislocation cells in the vicinity of the fatigue crack tip. Consequently the presented results indicate that the hydrogen enhanced localized plasticity (HELP) mechanism leads to accelerated crack growth and change in crack morphology for the materials investigated. In summary the cyclic indentation tests show a high potential for an analysis of the effects of hydrogen on the local cyclic deformation behaviour.
Towards Accident Prevention on Liquid Hydrogen: A Data-driven Approach for Releases Prediction
Mar 2023
Publication
Hydrogen is a clean substitute for hydrocarbon fuels in the marine sector. Liquid hydrogen (2 ) can be used to move and store large amounts of hydrogen. This novel application needs further study to assess the potential risk and safety operation. A recent study of 2 large-scale release tests was conducted to replicate spills of 2 inside the ship’s tank connection space and during bunkering operations. The tests were performed in a closed and outdoor facility. The 2 spills can lead to detonation representing a safety concern. This study analyzed the aforementioned 2 experiments and proposed a novel application of the random forests algorithm to predict the oxygen phase change and to estimate whether the hydrogen concentration is above the lower flammability limit (LFL). The models show accurate predictions in different experimental conditions. The findings can be used to select reliable safety barriers and effective risk reduction measures in 2 spills.
Improvement of MC Method in SAE J2601 Hydrogen Refuelling Protocol Using Dual-zone Dual-Temperature Model
Sep 2023
Publication
The MC method refuelling protocol in SAE J2601 has been published by the Society of Automotive Engineers (SAE) in order to safely and quickly refuel hydrogen vehicles. For the calculation method of the pressure target to control the refuelling stop we introduced a dual-zone dual-temperature model that distinguishes the hydrogen temperature in the tank from the wall temperature to replace the dual-zone single-temperature model of the original MC method. The total amount of heat transferred by convection between hydrogen and the inner tank wall during the filling process was expressed as an equation of final hydrogen temperature final wall temperature final refuelling time tank inner surface area and the correction factor. The correction factor equations were determined by fitting simulation data from the 0D1D model where hydrogen inside the tank is lumped parameter model (0D) and the tank wall is a one-dimensional model (1D). For the correction factor of the linear equation its first-order coefficient and constant term have a linear relationship with the initial pressure of the storage tank and their R2 values obtained from the fitting are greater than 0.99. Finally we derived a new equation to calculate the final hydrogen temperature which can be combined with the 100% SOC inside the vehicle tank to determine the pressure target. The simulation results show that the final SOC obtained are all greater than 96% using the modified pressure target and the correction factor of the linear equation.
Influence of Longitudinal Wind on Hydrogen Leakage and Hydrogen Concentration Sensor Layout of Fuel Cell Vehicles
Jul 2023
Publication
Hydrogen has the physical and chemical characteristics of being flammable explosive and prone to leakage and its safety is the main issue faced by the promotion of hydrogen as an energy source. The most common scene in vehicle application is the longitudinal wind generated by driving and the original position of hydrogen concentration sensors (HCSs) did not consider the influence of longitudinal wind on the hydrogen leakage trajectory. In this paper the computational fluid dynamics (CFD) software STAR CCM 2021.1 is used to simulate the hydrogen leakage and diffusion trajectories of fuel cell vehicles (FCVs) at five different leakage locations the longitudinal wind speeds of 0 km/h 37.18 km/h and 114 km/h and it is concluded that longitudinal wind prolongs the diffusion time of hydrogen to the headspace and reduces the coverage area of hydrogen in the headspace with a decrease of 81.35%. In order to achieve a good detection effect of fuel cell vehicles within the longitudinal wind scene based on the simulated hydrogen concentration–time matrix the scene clustering method based on vector similarity evaluation was used to reduce the leakage scene set by 33%. Then the layout position of HCSs was optimized according to the proposed multi-scene full coverage response time minimization model and the response time was reduced from 5 s to 1 s.
Risk Management of Energy Communities with Hydrogen Production and Storage Technologies
Jul 2023
Publication
The distributed integration of renewable energy sources plays a central role in the decarbonization of economies. In this regard energy communities arise as a promising entity to coordinate groups of proactive consumers (prosumers) and incentivize investment on clean technologies. However the uncertain nature of renewable energy generation residential loads and trading tariffs pose important challenges both at the operational and economic levels. We study how this management can be directly undertaken by an arbitrageur that making use of an adequate price-based demand response (real-time pricing) system serves as an intermediary with the central electricity market to coordinate different types of prosumers under risk aversion. In particular we consider a sequential futures and spot market where the aggregated shortage or excess of energy within the community can be traded. We aim to study the impact of new hydrogen production and storage technologies on community operation and risk management. These interactions are modeled as a game theoretical setting in the form of a stochastic two-stage bilevel optimization problem which is later reformulated without approximation as a single-level mixed-integer linear problem (MILP). An extensive set of numerical experiments based on real data is performed to study the operation of the energy community under different technical and economical conditions. Results indicate that the optimal involvement in futures and spot markets is highly conditioned by the community’s risk aversion and self-sufficiency levels. Moreover the external hydrogen market has a direct effect on the community’s internal price-tariff system and depending on the market conditions may worsen the utility of individual prosumers.
Hybrid Model Predictive Control of Renewable Microgrids and Seasonal Hydrogen Storage
Jun 2023
Publication
Optimal energy management of microgrids enables efficient integration of renewable energies by considering all system flexibilities. For systems with significant seasonal imbalance between energy production and demand it may be necessary to integrate seasonal storage in order to achieve fully decarbonized operation. This paper develops a novel model predictive control strategy for a renewable microgrid with seasonal hydrogen storage. The strategy relies on data-based prediction of the energy production and consumption of an industrial power plant and finds optimized energy flows using a digital twin optimizer. To enable seasonal operation incentives for long-term energy shifts are provided by assigning a cost value to the storage charge and adding it to the optimization target function. A hybrid control scheme based on rule-based heuristics compensates for imperfect predictions. With only 6% oversizing compared to the optimal system layout the strategy manages to deliver enough energy to meet all demand while achieving balanced hydrogen production and consumption throughout the year.
Thermocouple Thermal Inertia During Refuelling of Hydrogen Tanks: CFD Validation
Sep 2023
Publication
Fueling and defueling of hydrogen composite tanks is an important issue for the safe handling of hydrogen. To prevent temperature rise during refuelling (maximum allowed T=+85°C) the rate of fueling must be carefully controlled. Using Computational Fluid Dynamics (CFD) we simulate the temperature and velocity distribution inside the tank during these processes including cases where thermal stratification occurs. Simulations of two tank configurations with tilted injectors are presented along with experimental data validation. A model is proposed to account for the thermal inertia of the thermocouples making it possible to compare more reliably CFD results with experimental measurements.
Enhancing Safety of Liquid and Vaporised Hydrogen Transfer Technologies in Public Areas for Mobile Applications
Sep 2023
Publication
Federico Ustolin,
Donatella Cirrone,
Vladimir V. Molkov,
Dmitry Makarov,
Alexandros G. Venetsanos,
Stella G. Giannissi,
Giordano Emrys Scarponi,
Alessandro Tugnoli,
Ernesto Salzano,
Valerio Cozzani,
Daniela Lindner,
Birgit Gobereit,
Bernhard Linseisen,
Stuart J. Hawksworth,
Thomas Jordan,
Mike Kuznetsov,
Simon Jallais and
Olga Aneziris
International standards related to cryogenic hydrogen transferring technologies for mobile applications (filling of trucks ships stationary tanks) are missing and there is lack of experience. The European project ELVHYS (Enhancing safety of liquid and vaporized hydrogen transfer technologies in public areas for mobile applications) aims to provide indications on inherently safer and efficient cryogenic hydrogen technologies and protocols in mobile applications by proposing innovative safety strategies which are the results of a detailed risk analysis. This is carried out by applying an inter-disciplinary approach to study both the cryogenic hydrogen transferring procedures and the phenomena that may arise from the loss of containment of a piece of equipment containing hydrogen. ELVHYS will provide critical inputs for the development of international standards by creating inherently safer and optimized procedures and guidelines for cryogenic hydrogen transferring technologies thus increasing their safety level and efficiency. The aim of this paper is twofold: present the state of the art of liquid hydrogen transfer technologies by focusing on previous research projects such as PRESLHY and introduce the objectives and methods planned in the new EU project ELVHYS.
Design for Reliability and Safety: Challenges and Opportunities in Hydrogen Mobility Assets
Sep 2023
Publication
Safety and reliability are important performance attributes of any engineered system where humanmachine interactions are present. However they are usually approached as afterthoughts or in some cases unintended consequences of the system design and development process that must be addressed and verified in subsequent design stages. In plain words safety and reliability are often seen as constraints that add layers of complexity and extra costs to the minimum functional system of interest. No longer. Shell Hydrogen is embedding the Design for Reliability and Safety approach to engineer our products and assets in such a way that safety and reliability are at the core of a concurrent engineering process throughout the system lifecycle. This has been achieved in practice by leveraging systems reliability and safety engineering methods along with the experience and expertise of Shell Hydrogen original equipment manufacturers and system integrators in designing building and operating hydrogen assets for mobility applications.<br/>The challenges in implementing this approach are many ranging from access to historical data on equipment and component safety and reliability performance to lack of standardization in the industry when dealing with hydrogen related hazards. In this paper we will describe the approach in more detail some of our early successes and failures during deployment and the continual improvement journey that lies ahead.
An Experimental Study on the Large-Volume Liquid Hydrogen Release in an Open Space
Apr 2024
Publication
Liquid hydrogen is one of the high-quality energy carriers but a large leak of liquid hydrogen can pose significant safety risks. Understanding its diffusion law after accidental leakage is an important issue for the safe utilization of hydrogen energy. In this paper a series of open-space large-volume liquid hydrogen release experiments are performed to observe the evolution of visible clouds during the release and an array of hydrogen concentration sensors is set up to monitor the fluctuation in hydrogen concentration at different locations. Based on the experimental conditions the diffusion of hydrogen clouds in the atmosphere under different release hole diameters and different ground materials is compared. The results show that with the release of liquid hydrogen the white visible cloud formed by air condensation or solidification is generated rapidly and spread widely and the visible cloud is most obvious near the ground. With the termination of liquid hydrogen release solid air is deposited on the ground and the visible clouds gradually shrink from the far field to the release source. Hydrogen concentration fluctuations in the far field in the case of the cobblestone ground are more dependent on spontaneous diffusion by the hydrogen concentration gradient. In addition compared with the concrete ground the cobblestone ground has greater resistance to liquid hydrogen extension; the diffusion of hydrogen clouds to the far field lags. The rapid increase stage of hydrogen concentration at N8 in Test 7 lags about 3 s behind N12 in Test 6 N3 lags about 7.5 s behind N1 and N16 lags about 8.25 s behind N14. The near-source space is prone to high-concentration hydrogen clouds. The duration of the high-concentration hydrogen cloud at N12 is about 15 s which is twice as long as the duration at N8 increasing the safety risk of the near-source space.
Effect of Ignition Energy and Hydrogen Addition on Laminar Flame Speed, Ignition Delay Time, and Flame Rising Time of Lean Methane/Air Mixtures
Mar 2022
Publication
A series of experiments were performed to investigate the effect of ignition energy (Eig) and hydrogen addition on the laminar burning velocity (Su 0 ) ignition delay time (tdelay) and flame rising time (trising) of lean methane−air mixtures. The mixtures at three different equivalence ratios (φ) of 0.6 0.7 and 0.8 with varying hydrogen volume fractions from 0 to 50% were centrally ignited in a constant volume combustion chamber by a pair of pin-to-pin electrodes at a spark gap of 2.0 mm. In situ ignition energy (Eig ∼2.4 mJ ÷ 58 mJ) was calculated by integration of the product of current and voltage between positive and negative electrodes. The result revealed that the Su 0 value increases non-linearly with increasing hydrogen fraction at three equivalence ratios of 0.6 0.7 and 0.8 by which the increasing slope of Su 0 changes from gradual to drastic when the hydrogen fraction is greater than 20%. tdelay and trising decrease quickly with increasing hydrogen fraction; however trising drops faster than tdelay at φ = 0.6 and 0.7 and the reverse is true at φ = 0.8. Furthermore tdelay transition is observed when Eig > Eigcritical by which tdelay drastically drops in the pre-transition and gradually decreases in the post-transition. These results may be relevant to spark ignition engines operated under lean-burn conditions.
An Experimental Study of Propagating Spherical Flames in Unconfined Hydrogen-oxygen Explosions
Sep 2021
Publication
The study to understand the flame propagation behaviors of hydrogen-oxygen explosions is required to make a precise risk assessment. Moreover although research has investigated the propagating spherical flames in unconfined hydrogen-air explosions no study to date has examined the hydrogen-oxygen explosions. The spherical flame propagation in unconfined hydrogen-oxygen explosions have been investigated using a soap bubble method. In the present experiments hydrogen-oxygen mixtures were filled in a 10 cm diameter soap bubble and ignited by an electric spark at the center. The flame propagation behaviors were measured by a high-speed Schlieren photography. The laminar burning velocities and critical flame radii for the onset of flame acceleration in unconfined hydrogen-oxygen explosions were estimated. Results demonstrated that the laminar burning velocities of hydrogenoxygen mixtures were much faster than those of hydrogen-air mixtures. In addition the shift value of maximum laminar burning velocity for hydrogen-oxygen mixtures towards a leaner equivalence ratio is observed. The experimental flame speeds for all experiments were increased owing to diffusionalthermal and Darrieus-Landau instabilities although the measured flame radii were small. The critical flame radius corresponding to the onset of flame acceleration decreased with the decrease in equivalence ratio.
Construction of Natural Gas Energy-measuring System in China: A Discussion
Feb 2022
Publication
During the 13th Five-Year Plan China's natural gas industry developed rapidly and a diversified supply and marketing pattern was formed including domestic conventional gas unconventional gas (shale gas tight sandstone gas coalbed methane etc.) coal-based synthetic natural gas imported LNG and imported pipeline gas. The gross calorific value of gas sources ranged from 34 MJ/m3 to 43 MJ/m3 and the maximum difference of calorific value between different gas sources exceeded 20%. On May 24th 2019 the National Development and Reform Commission and other three ministries/commissions jointly issued the Supervision Regulation on the Fair Access of Oil and Gas Pipeline Network Facilities and required that a natural gas energy measuring and pricing system shall be established within 24 months from the implementation date of this Regulation. In order to speed up the construction of China's natural gas energy measuring system this paper summarizes domestic achievements in the construction of natural gas energy measuring system from the aspects of value traceability and energy measurement standard and analyzes natural gas flowrate measurement technology calorific value determination technology value traceability localization intelligentization and application technology of key energy measurement equipment natural gas pipeline network energy balancing technology based on big data analysis multi-source quality tracking and monitoring technology and energy measurement standard system the need of new energy detection and measurement technology and put forward strategy for the development of natural gas measuring in China. And the following research results are obtained. First China's natural gas energy measuring system can basically meet the requirements of implementing natural gas energy measurement but it still falls behind the international leading level in terms of calibration and application of high-level flowmeter (such as 0.5 class) high-accuracy gas reference material level of calorific value reference equipment and measurement standard system and needs to be further improved. Second it is necessary for China to speed up the research and application of the localization and intelligentization technologies of key energy measurement equipment. Third natural gas pipeline network shall be equipped with measurement check method energy balancing system based on big data analysis and multi-source quality tracking and monitoring system so that the energy transmission loss index of natural gas pipeline network can be superior to the international leading level (0.10%). Fourth to realize the large-scale application of hydrogen energy and bio-energy and the mixed transportation of hydrogen bio-methane and natural gas it is necessary to carry out research on new technology and standardization of hydrogen/bio-methane blended natural gas detection and measurement.
Australians’ Considerations for Use of Hydrogen in the Transport Sector
Sep 2019
Publication
Hydrogen fuel cells power a range of vehicles including cars buses trucks forklifts and even trains. As fuel cell electric vehicles emit no carbon emissions and only produce water vapor as a by-product they present an attractive option for countries who are experiencing high pollution from transport. This paper presents the findings of ten focus groups and a subset of a national survey which focused specifically on use of hydrogen in the transport sector (N=948). When discussing hydrogen transport options Australian focus group participants felt that rolling out hydrogen fuel cell buses as a first step for fuel cell electric vehicle deployment would be a good way to increase familiarity with the technology. Deploying hydrogen public transport vehicles before personal vehicles was thought to be a positive way to demonstrate the safe use of hydrogen and build confidence in the technology. At the same time it was felt it would allow any issues to be ironed out before the roll out of large-scale infrastructure on a to support domestic use. Long haul trucks were also perceived to be a good idea however safety issues were raised in the focus groups when discussing these vehicles. Survey respondents also expressed positive support for the use of hydrogen fuel cell buses and long-haul trucks. They reported being happy to be a passenger in a fuel cell bus. Safety and environmental benefits remained paramount with cost considerations being the third most important issue. Respondents supportive of hydrogen technologies were most likely to report purchasing a hydrogen vehicle over other options
Development of a Flashback Correlation for Burner-stabilized Hydrogen-air Premixed Flames
Feb 2022
Publication
With a growing need for replacing fossil fuels with cleaner alternatives hydrogen has emerged as a viable candidate for providing heat and power. However stable and safe combustion of hydrogen is not simple and as such a number of key issues have been identified that need to be understood for a safe design of combustion chambers. One such issue is the higher propensity of hydrogen flames to flashback compared to that for methane flames. The flashback problem is coupled with higher burner temperatures that could cause strong thermal stresses in burners and could hinder their performance. In order to systematically investigate flashback in premixed hydrogen-air flames for finding a global flashback criteria in this study we use numerical simulations as a basic tool to study flashback limits of slit burners. Flashback limits are found for varying geometrical parameters and equivalence ratios and the sensitivity of each parameter on the flashback limit and burner temperatures are identified and analyzed. It is shown that the conventional flashback correlation with critical velocity gradient does not collapse the flashback data as it does not take into account stretch induced preferential diffusion effects. A new Karlovitz number definition is introduced with physical insights that collapses the flashback data at all tested conditions in an excellent manner.
Why Ultrasonic Gas Leak Detection?
Sep 2021
Publication
Technologies that have traditionally been used in fixed installations to detect hydrogen gas leaks such as Catalytic and Electrochemical Point Sensors have one limitation: in order for a leak to be detected the gas itself must either be in close proximity to the detector or within a pre-defined area. Unfortunately outdoor environmental conditions such as changing wind directions and quick dispersion of the gas cloud from a leaking outdoor installation often cause that traditional gas detection systems may not alert to the presence of gas simply because the gas never reaches the detector. These traditional gas detection systems need to wait for the gas to form a vapor cloud which may or may not ignite and which may or may not allow loss prevention by enabling shutting down the gas facility in time. Ultrasonic Gas Leak Detectors (UGLD) respond at the speed of sound at gas leak initiation unaffected by changing wind directions and dilution of the gas. Ultrasonic Gas Leak Detectors are based on robust microphone technology; they detect outdoor leaks by sensing the distinct high frequency ultrasound emitted by all high pressure gas leaks. With the ultrasonic sensing technology leaking gas itself does not have to reach the sensor – just the sound of the gas leaking. By adding Ultrasonic Gas Leak Detectors for Hydrogen leak detection faster response times and lower operation costs can be obtained.
Modelling of Boil‐Off and Sloshing Relevant to Future Liquid Hydrogen Carriers
Mar 2022
Publication
This study presents an approach for estimating fuel boil‐off behaviour in cryogenic energy carrier ships such as future liquid hydrogen (LH2) carriers. By relying on thermodynamic model‐ ling and empirical formulas for ship motion and propulsion the approach can be used to investigate boil‐off as a function of tank properties weather conditions and operating velocities during a laden voyage. The model is first calibrated against data from a liquefied natural gas (LNG) carrier and is consequently used to investigate various design configurations of an LH2 ship. Results indicate that an LH2 ship with the same tank volume and glass wool insulation thickness as a conventional LNG carrier stores 40% of the fuel energy and is characterised by a boil‐off rate nine times higher and twice as sensitive to sloshing. Adding a reliquefaction unit can reduce the LH2 fuel depletion rate by at least 38.7% but can increase its variability regarding velocity and weather conditions. In calm weather LH2 boil‐off rates can only meet LNG carrier standards by utilising at least 6.6 times the insulation thickness. By adopting fuel cell propulsion in an LH2 ship a 1.1% increase in fuel delivery is expected. An LH2 ship with fuel cells and reliquefaction is required to be at least 1.7 times larger than an existing LNG carrierto deliverthe same energy. Further comparison of alternative scenarios indicates that LH2 carriers necessitate significant redesigns if LNG carrier standards are desired. The present approach can assist future feasibility studies featuring other vessels and propulsion technologies and can be seen as an extendable framework that can predict boil‐off in real‐time.
Temperature Effect on the Mechanical Properties of Liner Materials used for Type IV Hydrogen Storage Tanks
Sep 2021
Publication
Type IV hydrogen storage tanks play an important role in hydrogen fuel cell vehicles (HFCVs) due to their superiority of lightweight good corrosion and fatigue resistance. It is planned to be used between -40℃ and 85℃ at which the polymer liner may have a degradation of mechanical properties and buckling collapse. This demand a good performance of liner materials in that temperature range. In this article the temperature effect on mechanical properties of polyamide 6 (PA6) liner material including specimens with weld seam was investigated via the stress-strain curve (S-S curve) macroscopic and microscopic morphology. Considering that the mechanical properties will change after the liner molding process this test takes samples directly from the liner. Results show that the tensile strength and tensile modulus increased by 2.46 times and 10.6 times respectively with the decrease of temperature especially in the range from 50℃ to -90℃. For the elongation at break and work of fracture they do not monotonously increase with the temperature up. Both of them reduce when the temperature rises from 20°C to 50°C especially for the work of fracture decreasing by 63%. The weld seam weakens the mechanical properties and the elongation at break and work of fracture are more obvious which are greater than 40% at each temperature. In addition the SEM images indicate that the morphology of fracture surface at -90°C is different from that at other temperatures which is a sufficient evidence of toughness reducing in low temperature.
Numerical Investigation on the Flame Structure and CO/NO Formations of the Laminar Premixed Biogas–Hydrogen Impinging Flame in the Wall Vicinity
Nov 2021
Publication
The near-wall flame structure and pollutant emissions of the laminar premixed biogashydrogen impinging flame were simulated with a detailed chemical mechanism. The spatial distributions of the temperature critical species and pollutant emissions near the wall of the laminar premixed biogas–hydrogen impinging flame were obtained and investigated quantitatively. The results show that the cold wall can influence the premixed combustion process in the flame front which is close to the wall but does not touch the wall and results in the obviously declined concentrations of OH H and O radicals in the premixed combustion zone. After flame quenching a high CO concentration can be observed near the wall at equivalence ratios (ϕ) of both 0.8 and 1.2. Compared with that at ϕ = 1.0 more unburned fuel is allowed to pass through the quenching zone and generate CO after flame quenching near the wall thanks to the suppressed fuel consumption rate near the wall and the excess fuel in the unburned gases at ϕ = 0.8 and 1.2 respectively. By isolating the formation routes of NO production it is found that the fast-rising trend of NO concentration near the wall in the post flame region at ϕ = 0.8 is attributed to the NO transportation from the NNH route primarily while the prompt NO production accounts for more than 90% of NO generation in the wall vicinity at ϕ = 1.2. It is thus known that thanks to the effectively increased surface-to-volume ratio the premixed combustion process in the downsized chamber will be affected more easily by the amplified cooling effects of the cold wall which will contribute to the declined combustion efficiency increased CO emission and improved prompt NO production.
Differentiating Gas Leaks from Normal Appliance Use
Jun 2021
Publication
DNV has carried out an investigation into potential uses for smart gas meter data as part of Phase 1 of the Modernising Energy Data Applications competition as funded by UK Research & Innovation. In particular a series of calculations have been carried out to investigate the possibility of differentiating accidental gas leaks from normal appliance use in domestic properties. This is primarily with the aim of preventing explosions but the detection of leaks also has environmental and financial benefits.
Three gases have been considered in this study:
An examination of detailed historical incident information suggests that the explosions that lead to fatalities or significant damage to houses are typically of the type that would be more likely to be detected and prevented. It is estimated that between 25% and 75% of the more severe explosions could be prevented depending on which potential improvements are implemented.
Based on the conservative estimates of explosion prevention a cost benefit analysis suggests that it is justifiable to spend between around £1 and £10 per meter installed to implement the proposed technology. This is based purely on lives saved and does not take account of other benefits.
Three gases have been considered in this study:
- A representative UK natural gas composition.
- A blend of 80% natural gas and 20% hydrogen.
- Pure hydrogen.
- Small holes of up to 1 mm rarely reach flammable gas/air concentrations for any gas except under the most unfavourable conditions such as small volumes combined with low ventilation rates. These releases would likely be detected within 6 to 12 hours.
- Medium holes between 1 mm and 6 mm give outflow rates equivalent to a moderate to high level of gas use by appliances. The ability to detect these leaks is highly dependent on the hole size the time at which the leak begins and the normal gas use profile in the building. The larger leaks in this category would be detected within 30 to 60 minutes while the smaller leaks could take several hours to be clearly differentiated from appliance use. This is quick enough to prevent some explosions.
- Large holes of over 6 mm give leak rates greater than any gas use by appliances. These releases rapidly reach a flammable gas/air mixture in most cases but would typically be detected within the first 30-minute meter output period. Again some explosions could be prevented in this timescale.
An examination of detailed historical incident information suggests that the explosions that lead to fatalities or significant damage to houses are typically of the type that would be more likely to be detected and prevented. It is estimated that between 25% and 75% of the more severe explosions could be prevented depending on which potential improvements are implemented.
Based on the conservative estimates of explosion prevention a cost benefit analysis suggests that it is justifiable to spend between around £1 and £10 per meter installed to implement the proposed technology. This is based purely on lives saved and does not take account of other benefits.
Worst Case Scenario for Delayed Explosion of Hydrogen Jets at a High Pressure: Ignition Position
Sep 2021
Publication
Delayed explosion of free field hydrogen releases at a high pressure is subject of multiple investigation performed by various authors in the past years. These studied considered various parameters such as pressures flow rates etc. and their influence on the resulting overpressure. However the influence of the ignition position on the maximum overpressure was not fully explored. Current investigation addressed by computational fluid dynamics (CFD) simulations and experimental measurement fills this gap. This work demonstrates that the ignition positions corresponding to 55%-65% of H2/air mixture give the maximum overpressure. This observation initially observed numerically and afterword confirmed experimentally. A simple model is also suggested.
Numerical Study of the Action of Convection on the Volume and Length of the Flammable Zone Formed by Hydrogen Emissions from the Vent Masts Installed on an International Ship
Nov 2021
Publication
International ships carrying liquefied fuel are strongly recommended to install vent masts to control the pressure of cargo tanks in the event of an emergency. However the gas emitted from a vent mast may be hazardous for the crew of the ship. In the present study the volume and length of the flammable zone (FZ) created by the emitted gas above the ship was examined. Various scenarios comprising four parameters namely relative wind speed arrangement of vent masts combination of emissions among four vent masts and direction of emission from the vent-mast outlet were considered. The results showed that the convection acts on the volume and length of an FZ. The volume of an FZ increases when there is a reduction in convection reaching the FZ and when strong convection brings hydrogen from a nearby FZ. The length of the FZ is also related to convection. An FZ is elongated if the center of a vortex is located inside the FZ because this vortex traps hydrogen inside the FZ. The length of an FZ decreases if the center of the vortex is located outside the FZ as such a vortex brings more fresh air into the FZ.
The Effect of Symmetrically Tilt Grain Boundary of Aluminum on Hydrogen Diffusion
Feb 2022
Publication
High-strength aluminum alloys are widely used in industry. Hydrogen embrittlement greatly reduces the performance and service safety of aluminum alloys. The hydrogen traps in aluminum profoundly affect the hydrogen embrittlement of aluminum. Here we took a coincidence-site lattice (CSL) symmetrically tilted grain boundary (STGB) Σ5(120)[001] as an example to carry out molecular dynamics (MD) simulations of hydrogen diffusion in aluminum at different temperatures and to obtain results and rules consistent with the experiment. At 700 K three groups of MD simulations with concentrations of 0.5 2.5 and 5 atomic % hydrogen (at. % H) were carried out for STGB models at different angles. By analyzing the simulation results and the MSD curves of hydrogen atoms we found that in the low hydrogen concentration of STGB models the grain boundaries captured hydrogen atoms and hindered their movement. In high-hydrogen-concentration models the diffusion rate of hydrogen atoms was not affected by the grain boundaries. The analysis of the simulation results showed that the diffusion of hydro-gen atoms at the grain boundary is anisotropic.
Crack Management of Hydrogen Pipelines
Sep 2021
Publication
The climate emergency is one of the biggest challenges humanity must face in the 21st century. The global energy transition faces many challenges when it comes to ensuring a sustainable reliable and affordable energy supply. A likely outcome is decarbonizing the existing gas infrastructure. This will inevitably lead to greater penetration of hydrogen. While the introduction of hydrogen into natural gas transmission and distribution networks creates challenges there is nothing new or inherently impossible about the concept. Indeed more than 4000 kilometers of hydrogen pipelines are currently in operation. These pipelines however were (almost) all built and operated exclusively in accordance with specific hydrogen codes which tend to be much more restrictive than their natural gas equivalents. This means that the conversion of natural gas pipelines which have often been in service for decades and have accumulated damage and been subject to cracking threats (e.g. fatigue or stress corrosion cracking (SCC)) throughout their lifetime can be challenging. This paper will investigate the impact of transporting hydrogen on the crack management of existing natural gas pipelines from an overall integrity perspective. Different cracking threats will be described including recent industry experience of those which are generic to all steel pipelines but exacerbated by hydrogen and those which are hydrogen specific. The application of a Hydrogen Framework to identify characterise and manage credible cracking threats to pipelines in order to help enable the safe economic and successful introduction of hydrogen into the natural gas network will be discussed.
The Evolution and Structure of Ignited High-pressure Cryogenic Hydrogen Jets
Jun 2022
Publication
The anticipated upscaling of hydrogen energy applications will involve the storage and transport of hydrogen at cryogenic conditions. Understanding the potential hazard arising from leaks in high-pressure cryogenic storage is needed to improve hydrogen safety. The manuscript reports a series of numerical simulations with detailed chemistry for the transient evolution of ignited high-pressure cryogenic hydrogen jets. The study aims to gain insight of the ignition processes flame structures and dynamics associated with the transient flame evolution. Numerical simulations were firstly conducted for an unignited jet released under the same cryogenic temperature of 80 K and pressure of 200 bar as the considered ignited jets. The predicted hydrogen concentrations were found to be in good agreement with the experimental measurements. The results informed the subsequent simulations of the ignited jets involving four different ignition locations. The predicted time series snapshots of temperature hydrogen mass fraction and the flame index are analyzed to study the transient evolution and structure of the flame. The results show that a diffusion combustion layer is developed along the outer boundary of the jet and a side diffusion flame is formed for the near-field ignition. For the far-field ignition an envelope flame is observed. The flame structure contains a diffusion flame on the outer edge and a premixed flame inside the jet. Due to the complex interactions between turbulence fuel-air mixing at cryogenic temperature and chemical reactions localized spontaneous ignition and transient flame extinguishment are observed. The predictions also captured the experimentally observed deflagration waves in the far-field ignited jets.
Hydrogen Safety Challenges: A Comprehensive Review on Production, Storage, Transport, Utilization, and CFD-Based Consequence and Risk Assessment
Mar 2024
Publication
This review examines the central role of hydrogen particularly green hydrogen from renewable sources in the global search for energy solutions that are sustainable and safe by design. Using the hydrogen square safety measures across the hydrogen value chain—production storage transport and utilisation—are discussed thereby highlighting the need for a balanced approach to ensure a sustainable and efficient hydrogen economy. The review also underlines the challenges in safety assessments points to past incidents and argues for a comprehensive risk assessment that uses empirical modelling simulation-based computational fluid dynamics (CFDs) for hydrogen dispersion and quantitative risk assessments. It also highlights the activities carried out by our research group SaRAH (Safety Risk Analysis and Hydrogen) relative to a more rigorous risk assessment of hydrogenrelated systems through the use of a combined approach of CFD simulations and the appropriate risk assessment tools. Our research activities are currently focused on underground hydrogen storage and hydrogen transport as hythane.
Spontaneous Ignition of Cryo-Compressed Hydrogen in a T-Shaped Channel System
Aug 2022
Publication
Sudden releases of pressurised hydrogen may spontaneously ignite by the so-called “diffusion ignition” mechanism. Several experimental and numerical studies have been performed on spontaneous ignition for compressed hydrogen at ambient temperature. However there is no knowledge of the phenomenon for compressed hydrogen at cryogenic temperatures. The study aims to close this knowledge gap by performing numerical experiments using a computational fluid dynamics model validated previously against experiments at atmospheric temperatures to assess the effect of temperature decrease from ambient 300 K to cryogenic 80 K. The ignition dynamics is analysed for a T-shaped channel system. The cryo-compressed hydrogen is initially separated from the air in the T-shaped channel system by a burst disk (diaphragm). The inertia of the burst disk is accounted for in the simulations. The numerical experiments were carried out to determine the hydrogen storage pressure limit leading to spontaneous ignition in the configuration under investigation. It is found that the pressure limit for spontaneous ignition of the cryo-compressed hydrogen at temperature 80 K is 9.4 MPa. This is more than 3 times larger than pressure limit for spontaneous ignition of 2.9 MPa in the same setup at ambient temperature of 300 K.
Spherically Expanding Flame Simulations in Cantera Using a Lagrangian Formulation
Sep 2021
Publication
A Lagrangian-based one-dimensional approach has been developed using Cantera to study the dynamics of spherically expanding flames. The detailed reaction model USC-Mech II has been employed to examine flame propagating in hydrogen-air mixtures. In the first part our approach has been validated against laminar flame speed and Markstein number data from the literature. It was shown that the laminar flame speed was predicted within 5% on average but that discrepancies were observed for the Markstein number especially for rich mixtures. In the second part a detailed analysis of the thermo-chemical dynamics along the path of Lagrangian particles propagating in stretched flames was performed. For mixtures with negative Markstein lengths it was found that at high stretch rates the mixture entering the reaction-dominated period is less lean with respect to the initial mixture than at low stretch rate. This induces a faster rate of chemical heat release and of active radical production which results in a higher flame propagation speed. Opposite effects were observed for mixtures with positive Markstein lengths for which slower flame propagation was observed at high stretch rates compared to low stretch rates."
Blast Wave Generated by Delayed Ignition of Under-Expanded Hydrogen Free Jet at Ambient and Cryogenic Temperatures
Nov 2022
Publication
An under-expanded hydrogen jet from high-pressure equipment or storage tank is a potential incident scenario. Experiments demonstrated that the delayed ignition of a highly turbulent under-expanded hydrogen jet generates a blast wave able to harm people and damage property. There is a need for engineering tools to predict the pressure effects during such incidents to define hazard distances. The similitude analysis is applied to build a correlation using available experimental data. The dimensionless blast wave overpressure generated by delayed ignition and the follow-up deflagration or detonation of hydrogen jets at an any location from the jet ∆Pexp/P0 is correlated to the original dimensionless parameter composed of the product of the dimensionless ratio of storage pressure to atmospheric pressure Ps/P0 and the ratio of the jet release nozzle diameter to the distance from the centre of location of the fast-burning near-stoichiometric mixture on the jet axis (30% of hydrogen in the air by volume) to the location of a target (personnel or property) d/Rw. The correlation is built using the analysis of 78 experiments regarding this phenomenon in the wide range of hydrogen storage pressure of 0.5–65.0 MPa and release diameter of 0.5–52.5 mm. The correlation is applicable to hydrogen free jets at ambient and cryogenic temperatures. It is found that the generated blast wave decays inversely proportional to the square of the distance from the fast-burning portion of the jet. The correlation is used to calculate the hazard distances by harm thresholds for five typical hydrogen applications. It is observed that in the case of a vehicle with onboard storage tank at pressure 70 MPa the “no-harm” distance for humans reduces from 10.5 m to 2.6 m when a thermally activated pressure relief device (TPRD) diameter decreases from 2 mm to a diameter of 0.5 mm.
Stand-off Detection of Hydrogen Concentration
Sep 2021
Publication
The ability to remotely monitor hydrogen and map its concentration is a pressing challenge in large scale production and distribution as well as other sectors such as nuclear storage. We present a photonicsbased approach for the stand-off sensing and mapping of hydrogen concentration capable of detecting and locating <0.1% concentrations at 100m distance. The technique identifies the wavelength of light resulting from interaction with laser pulses via Raman scattering and can identify a range of other gas species e.g. hydrocarbons ammonia by the spectroscopic analysis of the wavelengths present in the return signal. LIDAR Light Detection and Ranging – analogous to Radar is used for ranging. Laserbased techniques for the stand-off detection of hydrocarbons frequently employ absorption of light at specific wavelengths which are characteristic of the gas species. Unfortunately Hydrogen does not exhibit strong absorption however it does exhibit strong Raman scattering when excited in the UV wavelength range. Raman scattering is a comparatively weak effect. However the use of solid-state detectors capable of detecting single photons known as SPADS (Single Photon Avalanche Photodiode) enables the detection of low concentrations at range while making use of precise time-of-flight range location correlation. The initial safety case which necessitated our development of stand-off hydrogen sensing was the condition monitoring of stored nuclear waste supported and funded by Sellafield and the National Nuclear Laboratory in the UK. A deployable version of the device has been developed and hydrogen characterisation has been carried out in an active nuclear store. Prior to deployment a full ignition risk assessment was carried out. To the best of our knowledge this technique is the strongest candidate for the remote stand-off sensing of hydrogen.
No more items...